Streszczenie treści zawartej na stronie nr. 1
User’s Manual
Utility Series UPS
UP425
ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:
www.cyberpowersystems.com/FAQs.htm
Streszczenie treści zawartej na stronie nr. 2
TABLE OF CONTENTS IMPORTANT SAFETY WARNINGS…………….……………………………………….………1 INSTALLING YOUR UPS SYSTEM…………………….………………………………….……2 - UNPACKING…… ………………………………………………………………..2 - HARDWARE INSTALLATION GUIDE…………………………………….……2 BASIC OPERATION…………………………………………...................................................2 - FRONT PANEL AND REAR PANEL DESCRIPTION....................................2 TROUBLESHOOTING……………………………………………………….........................….
Streszczenie treści zawartej na stronie nr. 3
UP425 Guaranteed Uninterruptible Power System IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS) This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate. CAUTION! UPS must be live parts inside can be energized by the
Streszczenie treści zawartej na stronie nr. 4
INSTALLING YOUR UPS SYSTEM UNPACKING Inspect the UPS upon receipt. The box should contain the following: (1) UPS Unit; (1) User’s Manual for UPS; (1) Warranty Registration Card; TM TM (1) PowerPanel Software Disk; (1) User’s Manual for PowerPanel ; (1) Serial Interface Cable (DB-9); (1) Serial-to-USB cable; (1) Telephone Cable HARDWARE INSTALLATION GUIDE 1. Connect the equipment to your UPS outlets. Items such as copiers, laser printers, vacuums, space heaters, or other lar
Streszczenie treści zawartej na stronie nr. 5
UP425 Guaranteed Uninterruptible Power System ◆ Power Switch Press the power button to turn the UPS ON or OFF ◆ Power On Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing “clean power”, free of surges and spikes ◆ Using Battery Indicator This illuminates during utility failure, indicating that the battery is supplying power to the battery-power supplied outlets. ◆ Battery Backup and Surge Protection Outlets Provid
Streszczenie treści zawartej na stronie nr. 6
TROUBLESHOOTING Problem Possible Cause Solution Recharge the battery by leaving the Batteries are not fully charged. UPS plugged in. The UPS does not perform expected runtime. Contact CyberPower Systems at Battery is slightly worn out. tech@cyberpowersystems.com The on/off switch is designed to Turn the UPS off. Wait 10 seconds and prevent damage by rapidly then turn the UPS on. turning it off and on. The unit is not connected to an The unit must be connected to a The UPS
Streszczenie treści zawartej na stronie nr. 7
UP425 Guaranteed Uninterruptible Power System TECHNICAL SPECIFICATIONS Model UP425 Capacity (VA) 425VA Capacity (Watts) 230W Input Input Voltage Range 100Vac – 140Vac Frequency Range 57 – 63 Hz Output On Battery Output Voltage Simulated Sine Wave at 120Vac +/- 5% On Battery Output Frequency 60 Hz +/- 1% Transfer Time (Typical) 4ms Overload Protection On Utility: Circuit Breaker, On Battery: Internal Current Limiting Surge Protection and Filtering
Streszczenie treści zawartej na stronie nr. 8
DEFINITIONS FOR ILLUMINATED LED INDICATORS Condition Power Using Wiring Circuit Alarm On Battery Fault Breaker On Off Off Set Off Normal Two Utility Failure- The UPS is providing battery power Off On On/Off Set Beeps to the Battery-Power Supplied outlets. Utility Failure- The UPS is providing battery Rapid Off On On/Off Set power. The rapid beeps indicate the battery will Beeps run out of charge within a few minutes. Two Overload- Occurs in the Full-tim
Streszczenie treści zawartej na stronie nr. 9
UP425 Guaranteed Uninterruptible Power System LIMITED WARRANTY AND POWER CONTROL GUARANTEE In purchasing UP425 in the United States or Canada, the original end user receives a Limited Warranty and CyberPower's Power Control Guarantee from Cyber Power Systems (USA), Inc. (for ease of reading, referred to as "CyberPower"). The Limited Warranty and the Power Control Guarantee are intended to be the original end-user's exclusive rights and remedies. The Limited Warranty and the Power Con
Streszczenie treści zawartej na stronie nr. 10
NOTE: Some States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty. Exclusive Remedies Under Limited Warranty. Your exclusive remedy and CyberPower's' sole obligations are as follows for the Product: If (a) the CyberPower Product you purchased and still own is defective in ma
Streszczenie treści zawartej na stronie nr. 11
UP425 Guaranteed Uninterruptible Power System The Limited Warranty does not cover Connected Equipment, but as is explained below, to be covered under the Power Control Guarantee, the Connected Equipment must have been damaged due to a failure of the Product. The Connected Equipment must have been damaged due to a defect in materials or workmanship of the Product In the event of damage to the Connected Equipment, your exclusive remedy, and CyberPower's sole obligations, are as follo
Streszczenie treści zawartej na stronie nr. 12
CyberPower’s Duties. CyberPower will inspect and examine the Product and the item(s) of Connected Equipment (or at CyberPower's election, your written statement and repair cost estimate for those item(s)). You must return the product for inspection. If the damage to Connected Equipment is covered by the Power Control Guarantee, CyberPower will (in addition to Limited Warranty remedies for the CyberPower Product itself) repair (or pay the costs of repair) or replace the Connected
Streszczenie treści zawartej na stronie nr. 13
UP425 Guaranteed Uninterruptible Power System 2. As to Connected Equipment, the Power Control Guarantee covers only damage within the specific terms of the Power Control Guarantee to Connected Equipment (and only up to the applicable aggregate ceiling amount). 3. The Power Control Guarantee does not cover damage to Connected Equipment or apply if the Product has been operated in a failure mode or not in compliance with CyberPower operating instructions and manuals, or if the Connect
Streszczenie treści zawartej na stronie nr. 14
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES. CyberPower does not sell the Products for use in high-risk activities. The Product is not designed or intended for use in hazardous environments requiring fail-safe performance, including the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, weapons systems, life support or medical applications or for use in any circumstance in which the failure of the Pro