Installation Instructions
Combi-Steam Oven
DGC 4084 XL
DGC 4086 XL
en - US, CA
To prevent accidents
and appliance damage
read these instructions
before
installation or use. M.-Nr. 09 064 870
Streszczenie treści zawartej na stronie nr. 2
Contents IMPORTANT INSTALLATION SAFETY INSTRUCTIONS...................3 Installation .......................................................4 Cut-out for venting the combi-steam oven ...............................6 Appliance and installation dimensions................................8 Installation in a tall cabinet ...........................................8 Installation under a countertop ........................................9 Installation in combination with an oven ......................
Streszczenie treści zawartej na stronie nr. 3
IMPORTANT INSTALLATION SAFETY INSTRUCTIONS Be certain your appliance is WARNING - Read all instructions properly installed and grounded by a before installation or use of the qualified technician. To guarantee the steam oven to prevent injury and electrical safety of this appliance, machine damage. continuity must exist between the appliance and an effective grounding Installation, repair and maintenance system. It is imperative that this basic work should be performed by a Miele safety req
Streszczenie treści zawartej na stronie nr. 4
Installation Miele appliances can be installed flush or proud. Discuss your installation requirements with your architect, designer or installer. Dimension details of the appliance front 7/8" 22*/23** 7/8" 1 47,5 -2 4 9/16" 17 446 3/16" 4 3,8" 1/8" 13 4 111,5 333 3/4" 17 451,5 15/16" 17 455,5 1* 1**
Streszczenie treści zawartej na stronie nr. 5
Installation Dimension to allow the control panel to open and close The area in front of the control panel must not be blocked by anything (such as a door handle) this would hinder the control panel from opening and closing. 5
Streszczenie treści zawartej na stronie nr. 6
5/8" 1 (40 mm) Installation Cut-out for venting the combi-steam oven Installation in a tall cabinet a b To ensure that the combi-steam oven has adequate ventilation, the following 11 9 cut-outs measuring 19 / "x1 / " (500 x 40 mm) must be provided: 16 16 in the top of the cabinet in the center shelf above the installation niche If installing in combination with an oven please refer to the installation instructions included with the oven for oven venting instructions. 6 5/8" 19 (500 mm)
Streszczenie treści zawartej na stronie nr. 7
5/8" (40 mm) 1 Installation Installation under a countertop a b To ensure that the combi-steam oven has adequate ventilation, the following 11 9 cut-outs measuring 19 / "x1 / " (500 x 40 mm) must be provided: 16 16 in the appliance support shelf in the bottom of the cabinet space below it 7 5/8" 19 (500 mm)
Streszczenie treści zawartej na stronie nr. 8
21 1/2" (547 mm) 7/8" (22 mm*/ 23 mm**) ( 555 mm) 1 21 0 7/8" 5/8" (40 mm) Appliance and installation dimensions Installation in a tall cabinet d b c e a Combi-steam oven b Installation niche Terminal block Outlet or junction box This should be accessible after the appliance has been installed. Power cord (5 ft.) * Appliances with glass front / ** Appliances with metal front 8 5/8" 19 (500 mm) 1/16" 5/8" 3/8" 21 (549 mm) (560 mm - 568 mm) 22 - 22 (595 mm) 7/16" 23 5/8" 13/16" 9/16" 15/1
Streszczenie treści zawartej na stronie nr. 9
21 1/2" (547 mm) 7/8" (22 mm*/ 23 mm**) ( 555 mm) 21 0 7/8" Appliance and installation dimensions Installation under a countertop If the appliance is be installed under a cooktop, observe the installation instructions for the cooktop and its installation height. d c e b a Combi-steam oven Installation niche Terminal block Outlet or junction box This should be accessible after the appliance has been installed. Power cord (5 ft.) * Appliances with glass front / ** Appliances with metal
Streszczenie treści zawartej na stronie nr. 10
(22 mm*/ 23 mm**) 7/8" 1/16" 0 1 21 7/8" ( 555 mm) 3/8" 22 5/8" 7/8" 1/2" (560 mm - 568 mm) (22 mm* /23 mm**) 21 (547 mm) - 22 (40 mm) Appliance and installation dimensions Installation in combination with an oven d b c e a f Combi-steam oven Installation niche Terminal block Outlet or junction box This should be accessible after the appliance has been installed. Power cord (5 ft.) Oven * Appliances with glass front / ** Appliances with metal front See the "Cut-out for venting the c
Streszczenie treści zawartej na stronie nr. 11
9/16" (548 mm) 21 1/2" (22*/23**mm) 21 (547 mm) (3 mm) (7 mm) 7/8" 1/8" 1/4" ( 555 mm) 1 21 0 7/8" 5/8" 7/8" (22 mm* /23 mm**) (40 mm) Appliance and installation dimensions Installation in combination with ESW 408x-14 d b c e a Combi-steam oven Installation niche Terminal block Outlet or junction box This should be accessible after the appliance has been installed. Power cord (5 ft.) Built-in plate warmer / built-in food warmer * Appliances with glass front / ** Appliances with meta
Streszczenie treści zawartej na stronie nr. 12
9/16" (548 mm) 21 1/2" (22*/23**mm) 21 (547 mm) (3 mm) (4 mm) 7/8" 1/8" 1/8" ( 555 mm) 1 21 0 7/8" 5/8" 7/8" (22 mm* /23 mm**) (40 mm) Appliance and installation dimensions Installation in combination with ESW 408x-14 BRWS d b c e a Combi-steam oven Installation niche Terminal block Outlet or junction box This should be accessible after the appliance has been installed. Power cord (5 ft.) Built-in plate warmer / built-in food warmer * Appliances with glass front / ** Appliances with
Streszczenie treści zawartej na stronie nr. 13
Appliance and installation dimensions Installing the appliance Push the appliance into the cabinet niche and align it. The device must be level, so that the steam generator can operate properly. Deviation from a horizontal position should not exceed 2°. Secure the appliance by screwing the two 3.5 x 25 mm wood screws (supplied) into the vertical strips on either side of the housing. 13
Streszczenie treści zawartej na stronie nr. 14
Electrical connection Power supply CAUTION: Before installation or servicing, disconnect the power Installation, repairs and other work supply by either removing the fuse, by unqualified persons could be shutting off the main power or dangerous. manually "tripping" the circuit Be sure your electrical supply breaker. matches the data plate. Installation work and repairs should The appliance is equipped witha5ft. only be performed by a qualified (1.5 m) flexible power cord encasing 3 technician
Streszczenie treści zawartej na stronie nr. 15
15
Streszczenie treści zawartej na stronie nr. 16
Alteration rights reserved / 1013 M.-Nr. 09 064 870 / 03 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.