Streszczenie treści zawartej na stronie nr. 1
I n s t a l l a t I o n I n s t r u c t I o n s
c l a s s I c W a l l o v e n s
FOR MODELS: ECD227, ECD230, ECS127, ECS130, ECS136, ECS227, ECS230,
MCD227, MCD230, MCS127, MCS130 MCS227, MCS230, PCD230,
PCS130, PCS230
Part No. 65030 Rev. G
Streszczenie treści zawartej na stronie nr. 2
Streszczenie treści zawartej na stronie nr. 3
Table of Con Tne Ts Appliance Safety ..........................................................................1 Installation Instructions ........................................................6-9 Important Safety Instructions .....................................................2 Removing The Oven Doors ............................................................6 Design Specifications ...............................................................3-4 Turning Off The Power Supply ...........
Streszczenie treści zawartej na stronie nr. 4
i mpo RT an T s efa Ty i ns TRu CTnois NOTES: WARNING 1. Some products, such as whole eggs, and sealed To reduce the risk of burns, electric shock, fire or injury containers such as closed glass jars may explode to persons: and should not be heated in this oven. 1. Read all instructions before using the appliance. 2. To reduce the risk of fire in the oven cavity: Do not overcook food. Carefully attend the appliance if 2. This appliance must be grounded. Connect only paper, plastic or
Streszczenie treści zawartej na stronie nr. 5
d ngise s ep Cifi Ca Tsnoi NOTE: p Rodu CT d simeinsno Electrical junction box may be located: NOTE: 1. Above the oven cutout, to the right. All dimensional tolerances are + 2. Below the oven platform, to the right. 1/16”, - 0” unless otherwise stated. "D" Recommended Electrical 1 1/2" (38mm) electrical access Typical counter top access 1 1 "D" "C" 24" "B" (610mm) Alternate 36" Min. interior electrical (915mm) cabinet depth access 2 "B" "A" 3/4" (19mm) "A" Support platform (flush with cutout
Streszczenie treści zawartej na stronie nr. 6
d esign s pe Cifi Ca Tosni p Rodu CT d imnensios Dacor® Overall Overall Chassis Recess Recess Recess Model Width Height Depth Width Height Depth Number “E” “F” “G” “H” “J” “K” ECS127 27” 5” (686mm) (127mm) MCS127 28 3/8” ECS130 (721mm) 30” 6 1/4” PCS130 (762mm) (159mm) MCS130 36” 28 5/8” 6 3/8” ECS136 (914mm) (727mm) (162mm) ECS227 5 1/4” 8” MCS227 27” 23 7/8” 5” (133mm) (203mm) (686mm) (127mm) ECD227 MCD227 ECS230 49 7/8” (1268mm) PCS230 MCS230 30” 6 1/4” (762mm) (159mm) ECD230 PCD230 MCD230 O
Streszczenie treści zawartej na stronie nr. 7
i ns T alla Toin s pe Ciif Ca Tsino e le CTRi Cal p woe R s y lppu v e Rifyign Teh p a Caegk Con Tne Ts Verify that all required components have been provided. If Riuqe Rneem Ts any item is missing or damaged, please contact your dealer It is the owner’s responsibility to ensure that a qualified electrician immediately. Do not install a damaged or incomplete appliance. performs the electrical connection of this appliance. The electrical • Mounting Screws installation, including minimum su
Streszczenie treści zawartej na stronie nr. 8
i ns T alla Toin i ns TRu CToins Dacor Max. 208V Max. 240V Power Model Number Connected Load Connected Load Supply ECS127 MCS127 208/240V 25 Amps 22 Amps ECS130 4-wire (5.2kW) (5.2kW) NOTE: 60Hz, 30A PCS130 The four (4) leads supplied with this appliance are UL recognized MCS130 for connection to larger gauge 29 Amps household wiring. The insulation ECS136 n/a (7.0kW) of these leads is rated at temperatures much higher ECS227 than the temperature rating of MCS227 household wiring. The cur
Streszczenie treści zawartej na stronie nr. 9
i sn T alal Tnoi i sn TRu CTosni Cable from Tu Rning o ff The p ewo R s y lpup power supply Before attempting to connect the appliance to power, turn off the Junction box electrical power supply. Also, always turn off electrical power to the appliance prior to servicing it. WARNING WARNING – Failure to disconnect power may result in RED electrical shock or fire hazard. WHITE RED WHITE GREEN e el CTRi Cla Cenon CToni BLACK GREEN BLACK WARNING Wire nut (4 places) 1. This appliance must be con
Streszczenie treści zawartej na stronie nr. 10
i ns T alla Tion i sn TRu CTions C. Connecting the Green Appliance Wire to a WARNINGS Grounded Junction Box Wire or Grounded Cold 1. Do not ground the appliance to a gas supply pipe or hot Water Pipe – Where Local Codes Permit water pipe. 2. Do not turn on power to the appliance until the oven is 1. Separate the green and white appliance wires. permanently grounded. 3. Grounded cold water pipe must have metal continuity 2. Connect the black appliance wire to the black (L1) power supply wi
Streszczenie treści zawartej na stronie nr. 11
i ns T alla Toin i ns TRu CToisn Rinse T llinga The o ven d oo Rs i ns T alling Teh e xhaus T g Rill With the oven now secured to the cabinet, install the Exhaust Grill WARNING by mounting it to the oven with the two screws provided. WARNING – Failure to fully rotate the hinge catches will cause them to bend when the door is closed. This will make NOTE: closing the door impossible. You may need to loosen the side mounting screws a little to align the Exhaust Grill mounting holes. Tighten t
Streszczenie treści zawartej na stronie nr. 12
s e R vi Ce i onf Rma Tion If you need service, be sure to have the model and serial numbers avalable when you call. Contact a Dacor authorized servicer, a Dacor dealer or the Dacor Customer Service Team at (800) 793-0093. 10
Streszczenie treści zawartej na stronie nr. 13
n o Tes 11
Streszczenie treści zawartej na stronie nr. 14
n o Tes 12
Streszczenie treści zawartej na stronie nr. 15
n o Tes 13
Streszczenie treści zawartej na stronie nr. 16
Web Site: www.Dacor.com Phone: (800) 793-0093 © 2006 Dacor, all rights reserved.