Streszczenie treści zawartej na stronie nr. 1
®
Cleaning Instructions,
Pilot Replacement and
Valve Change
Model No.:
233010
Natural Gas
Streszczenie treści zawartej na stronie nr. 2
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Tools required: • 8mm open-end wrench • 9mm open-end wrench • 10mm open-end wrench • 12mm open-end wrench • 13mm open-end wrench • Phillips screw driver • 5/8” open end wrench • 3/4” open end wrench • Needle nose pliers • Soap and water solution (to check for leaks) DANGERS and Cautions 1. Installation and repair should be done by a qualified service person. 2. Use only Blue Rhino Global Sourcing, LLC. factory authorize
Streszczenie treści zawartej na stronie nr. 3
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Steps 1-4 1. T urn gas supply off and disconnect from gas supply. Important: make sure your gas supply is off. 2. Remove dome. 3. Remove engine from post. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 1 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 2
Streszczenie treści zawartej na stronie nr. 4
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 5 Remove the three bolts which secure the emitter to the emitter bottom using a 9mm wrench. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 3 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 4
Streszczenie treści zawartej na stronie nr. 5
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 6 1. Clean the carbon build-up off the inside of the emitter bottom with a non-abrasive scouring pad or bottle brush. Clean the outside of the emitter bottom with the scouring pad. 2. Use the air compressor to blow away any excess soot. DANGER : Never use any flammable solutions or material to clean heater or heater parts. Use only a mild soap and water solution. Do not to soak the valve. Cleaning burner, p
Streszczenie treści zawartej na stronie nr. 6
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 7 Disconnect the pilot supply tube using #10 open-ended wrench. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 5 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 6
Streszczenie treści zawartej na stronie nr. 7
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 8 Disconnect the burner supply tube from the control valve using 5/8” open-ended wrench. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 5 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 6
Streszczenie treści zawartej na stronie nr. 8
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 9 1. Disconnect the burner from the emitter bottom by removing the 2 phillips screws on the bottom of the emitter bottom. 2. Carefully remove the burner. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 7 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 8
Streszczenie treści zawartej na stronie nr. 9
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 10 Disconnect the thermal couple wire from the control valve: 1. Remove the screw that holds the access panel to the housing. 2. Remove the nut from the back of the control valve using 8 mm open-ended wrench. Note: Be very careful not to damage any wires. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 7 Cleaning burner, pilot replacement and valve change. Model No. 2
Streszczenie treści zawartej na stronie nr. 10
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 11 Remove the heat and pilot shield from the emitter bottom. 1. Remove the 4 screws in emitter bottom. Note: 2 screws are near pilot opening, and 2 screws are on the back side of the emitter bottom. 2. Lift the heat shield assembly out. Note: Be very careful not to damage any wires. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 9 Cleaning burner, pilot replacement a
Streszczenie treści zawartej na stronie nr. 11
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 12 1. Remove the pilot assembly by removing the 2 screws that hold the pilot assembly in place Note: you may need to use a pair of needle nose pliers to hold the nuts in place. 2. If replacing the pilot: A. Remove the ignitor wire, by carefully bending the fork on the retaining bracket up using need nose pliers B. Pull down on the ceramic tube C. Disconnect the igniter wire from the pilot. D. Replace the old
Streszczenie treści zawartej na stronie nr. 12
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 13 1. Remove the orifice by placing the 12 mm open-ended on the pilot orifice and the 10 mm open-ended on the hex tube just below the pilot hood. 2. Use a pipe cleaner to clean both the inside and outside of the pilot orifice. 3. With a brush, lightly clean the top of the pilot orifice. Use care not to enlarge the orifice hole. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Ga
Streszczenie treści zawartej na stronie nr. 13
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. 1. Use a heavy-duty pipe cleaner to clean the bottom of the black hex tube on the pilot assembly. Make sure to extend the pipe cleaner past the silver hood. 2. Clean the port at the side of the pilot hood with a heavy-duty pipe cleaner. 3. Blow out any excess soot or debris with an air hose or a can of compressed air. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 11 Clea
Streszczenie treści zawartej na stronie nr. 14
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 14 Insert bottle brush into venturi tube and give a couple of twists. This will clear any debris or spider webs from the venturi tube. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 13 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 14
Streszczenie treści zawartej na stronie nr. 15
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 15 1. Insert a heavy-duty pipe cleaner into each burner port to clean them. Use a non-abrasive scouring pad to clean the outside of the burner. 2. Using an air hose or can of compressed air to blow any excess soot from the burner ports and the venturi tube. 3. Use a brush or compressed air to clean the burner orifice. Note: Be careful not to enlarge any holes. Cleaning burner, pilot replacement and valve cha
Streszczenie treści zawartej na stronie nr. 16
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 16 If this is all you need to do then follow instructions in reverse to reassemble heater. If not, please continue. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 15 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 16
Streszczenie treści zawartej na stronie nr. 17
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 17 Replacing the control valve: 1. Remove the control valve by removing the 3/4” brass nut on the front side of the valve housing. 2. Push the control valve back and pull it out from the front of the valve housing. Note: Be careful not to damage the pilot supply tube. 3. Remove the pilot supply tube from the old control valve using 13 mm open-ended wrench or 1/2” open-ended wrench. Cleaning burner, pilot replace
Streszczenie treści zawartej na stronie nr. 18
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. 4. Attach the pilot supply tube to the new control valve 5. Install the new control valve. Note: Make sure the valve is secure. 6. Reattach the 3/4” brass nut. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 17 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 18
Streszczenie treści zawartej na stronie nr. 19
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 18 1. Place pilot assembly with heat shield into the emitter bottom 2. Attach the pilot supply tube to the pilot. 3. Tighten the screws that hold the guard in place. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 17 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 18
Streszczenie treści zawartej na stronie nr. 20
® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 19 1. Reinstall the thermal couple by attaching the nut on the back of the control valve, using the 8 mm open-end wrench. Note: Finger tighten the nut, plus a 1⁄4 turn 2. Reinstall the access panel. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 19 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 20