Streszczenie treści zawartej na stronie nr. 1
2103/2103c
Modem Module
Installation and Operation Guide
Part #69-2003-180
Copyright © 2002. All rights reserved, Teledyne Isco, Inc.
Revision M, September 6, 2006
Streszczenie treści zawartej na stronie nr. 2
Streszczenie treści zawartej na stronie nr. 3
Foreword This instruction manual is designed to help you gain a thorough understanding of the operation of the equipment. Teledyne Isco recommends that you read this manual completely before placing the equipment in service. Although Teledyne Isco designs reliability into all equipment, there is always the possi- bility of a malfunction. This manual may help in diagnosing and repairing the malfunc- tion. If the problem persists, call or e-mail the Teledyne Isco Technical Service Department for a
Streszczenie treści zawartej na stronie nr. 4
Streszczenie treści zawartej na stronie nr. 5
2103 Modem Module Table of Contents Section 1 Introduction 1.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2 Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.3 Identifying Module Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1.4 Safety Symbols and Hazard Alerts . . . . . . . . . . . . . . .
Streszczenie treści zawartej na stronie nr. 6
2103 Modem Module Table of Contents 5.3.2 Reactivating the Desiccant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 5.4 Hydrophobic Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 5.5 O-Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 5.6 How to Obtain Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Streszczenie treści zawartej na stronie nr. 7
2103 Modem Module Section 1 Introduction 1.1 Introduction This instruction manual is designed to help you gain a thorough understanding of the operation of the 2103 and 2103c Modem Modules. Teledyne Isco recommends that you read this manual completely before placing the equipment into service. Information in this manual pertains to both the 2103 phone line modem and the 2103c cellular modem, except for sections specific to one method of communication or the other. For detailed information about
Streszczenie treści zawartej na stronie nr. 8
2103 Modem Module Section 1 Introduction 1.3 Identifying Module Figures 1-1 and 1-2 identify the key components of the 2103 Modem. Components 1 2 3 5 6 4 Figure 1-1 2103 Modem Components - Top View Table 1-1 2103 Modem Module Components - Top View Item No. Name Description 1 Communication Connector This port is used to connect the 2103 Modem to other modules in a stack. 2 Connector Cap Insert into the communication connector when it is not in use to protect the connector from moisture damage.
Streszczenie treści zawartej na stronie nr. 9
2103 Modem Module Section 1 Introduction 1 2 3 4 5 Figure 1-2 2103 Modem Components - Bottom View Table 1-2 2103 Modem Module Components - Bottom View Item No. Name Description 1 Communication Connector This connects the 2103 Modem to other 2100 Series modules in the stack and is used to transfer data. 2 Connector Cap Insert into the communication connector when not in use to protect the connector from moisture damage. When the connector is in use, store the connector cap in the cap holder. 3
Streszczenie treści zawartej na stronie nr. 10
2103 Modem Module Section 1 Introduction Table 1-3 2103 Modem Module Technical Specifications Dimensions Length = 10.5 inches (26.7 cm) Width = 7.5 inches (19 cm) Height = 2.9 inches (7.4 cm) Weight 2 lbs. (.9 Kg) Material High-impact molded polystyrene Enclosure NEMA 4X, 6P, IP68 (2103), IP67 (2103c) Power 6.6 to 16.6 VDC, 141 mA typical at 12 VDC, 0.41 mA standby Operating Temperature -4° to 140°F (-20° to 60°C) Storage Temperature -40° to 140°F (-40° to 60°C) Typical Battery Life 291 days* Mo
Streszczenie treści zawartej na stronie nr. 11
2103 Modem Module Section 1 Introduction G F A E B D C Table 1-5 2103 Communication Connector Pins (2103 only) Pin Name Description A LONA Neuron differential transceiver Data A B LONB Neuron differential transceiver Data B C VIN+ Positive power supply voltage input (+12 VDC nominal) D VIN– Negative power supply voltage input (0 VDC nominal) E RCVUP PC data receiver inverted input F XMTUP PC data transmit inverted output G Key Aligns connector pins Figure 1-3 2103 Communication Connector Pins 1-
Streszczenie treści zawartej na stronie nr. 12
2103 Modem Module Section 1 Introduction Figure 1-4 2103 Modem Cable Connector 1.4 Safety Symbols and This icon identifies a general hazard and is accompanied with details about the hazard. The instruction manual Hazard Alerts identifies the hazardous condition and any steps nec- essary to correct the condition. The manual presents this infor- mation in one of two ways: CAUTION Cautions identify a potential hazard, which if not avoided, may result in minor or moderate injury. This category can a
Streszczenie treści zawartej na stronie nr. 13
2103 Modem Module Section 1 Introduction 1.5 Technical Service Although Teledyne Isco designs reliability into all of its equipment, there is always the possibility of a malfunction occurring. You can use this manual to help in diagnosing and repairing any malfunctions. If the malfunction persists, call or write the Teledyne Isco Technical Service Department for assis- tance: Teledyne Isco Inc. Technical Service Department P.O. Box 82531 Lincoln, NE 68501 800-228-4373 or 402-464-0231 FAX: 402-46
Streszczenie treści zawartej na stronie nr. 14
2103 Modem Module Section 1 Introduction 1-8
Streszczenie treści zawartej na stronie nr. 15
2103 Modem Module Section 2 Installation and Operation 2.1 Unpacking When the system arrives, inspect the contents for any damage. If there is damage, contact the delivery company and Teledyne Isco Instructions (or its agent) immediately. WARNING If there is any evidence that any items may have been damaged in shipping, do not attempt to install the unit. Please contact Teledyne Isco (or its agent) for advice. When you unpack the system, check the items against the Teledyne Isco, Inc. packing
Streszczenie treści zawartej na stronie nr. 16
2103 Modem Module Section 2 Installation and Operation hazardous environments that can prove fatal for those unpre- pared. These spaces are governed by OSHA 1910.146 and require a permit before entering. 2.3 Installation Follow the instructions below to install your 2103 Modem. 2.3.1 Latches - Locking and Latches must be operated to stack and unstack the modules in a Unlocking Series 2100 stack. The mechanisms are the same for the 2103 Modem and other 2100 Series modules. Detailed instructions w
Streszczenie treści zawartej na stronie nr. 17
2103 Modem Module Section 2 Installation and Operation 2.3.3 Stacking Modules The 2103 Modem Module can be located anywhere within a stack of up to three 2100 Series networked modules. It will draw its power from the battery module located in the stack. To connect the 2103 with a 2100 Series module, refer to the fol- lowing instructions. 1. On the top of the 2100 Series module, remove the cap and stow it on the holder. This exposes the communication con- nector on the module. 2. Inspect the mod
Streszczenie treści zawartej na stronie nr. 18
2103 Modem Module Section 2 Installation and Operation service is subject to state tariffs. Changes in Attestation Procedure for Plugs and Jacks Isco Inc. attests that the network interface plugs or jacks used on this equipment comply with and will continue to comply with the mechanical requirements specified in Part 58, sub-part F, specifically the dimensions, tolerances and metallic plating requirements. The compliance of these connectors will be assured by purchase specifications and incoming
Streszczenie treści zawartej na stronie nr. 19
2103 Modem Module Section 2 Installation and Operation 2.4.1 Modem Cable After you have installed the 2103 on the stack, you need to attach Connection the modem cable so the module can be connected to a phone line. Remove the connector cap from the 5-pin circular modem cable connector on the right hand side of the 2103. Attach the modem cable to the connector (Figure 2-1), and then connect the other end of the modem cable to a standard telephone jack (USOC RJ-11C). Figure 2-1 Connecting the Mode
Streszczenie treści zawartej na stronie nr. 20
2103 Modem Module Section 2 Installation and Operation 2.5 Connecting to After the 2103 is installed and the modem cable connected, you need to configure the 2103 in Isco’s Flowlink software. Flowlink Note The 2103 Modem requires Flowlink 4.13 or later. Earlier ver- sions do not support the Modem. The Modem requires that the 2100 Series modules it connects to have a code version 1.06 or greater. Open Flowlink and go to the connect box (Figure 2-3) by either selecting it from the pull down menu