Streszczenie treści zawartej na stronie nr. 1
®
Cyclades P M IPDU
For Technical Support:
Installer/Administrator/User Guide
www.avocent.com/support
Avocent International Ltd.
Avocent Corporation
Avocent House, Shannon Free Zone
4991 Corporate Drive
Shannon, County Clare, Ireland
Huntsville, Alabama 35805-6201 USA
Tel: +353 61 715 292
Tel: +1 256 430 4000
Fax: +353 61 471 871
Fax: +1 256 430 4031
Avocent Germany
Avocent Asia Pacific
Gottlieb-Daimler-Straße 2-4
Singapore Branch Office
D-33803 Steinhagen
100 Tras Street, #15-01
Germany
Ama
Streszczenie treści zawartej na stronie nr. 2
FCC Warning Statement The Cyclades PM IPDU has been tested and found to comply with the limits for Class A digital devices, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Installation & Service Manual, may cause harmful interference
Streszczenie treści zawartej na stronie nr. 3
® Cyclades PM IPDU Installer/Administrator/User Guide Avocent, the Avocent logo, The Power of Being There, Cyclades and DSR are registered trademarks of Avocent Corporation or its affiliates. All other marks are the property of their respective owners. © 2007 Avocent Corporation. All rights reserved. 590-667-501B
Streszczenie treści zawartej na stronie nr. 4
Instructions This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. Dangerous Voltage This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Power On This symbol indicates the principal on/off switch is in the on position. Power
Streszczenie treści zawartej na stronie nr. 5
iii TABLE OF CONTENTS Table of Contents List of Figures ................................................................................................................ vii List of Tables................................................................................................................... ix Chapter 1: Introduction ................................................................................................... 1 Features and Benefits .............................................
Streszczenie treści zawartej na stronie nr. 6
iv Cyclades PM IPDU Installer/Administrator/User Guide Daisy chained PM IPDUs in the login prompt......................................................................... 13 Logging in to the PM IPDU......................................................................................................13 Commands ....................................................................................................................................... 14 Appendices...............................
Streszczenie treści zawartej na stronie nr. 7
vii LIST OF FIGURES List of Figures Figure 1.1: Standalone Configuration............................................................................................... 2 Figure 1.2: Daisy Chained PM IPDUs with an Avocent Management Device................................. 3 Figure 2.1: Rack Mount Bracket Installation on a PM IPDU........................................................... 6 Figure 2.2: A Sample PM IPDU (PM42 Shown)..................................................................
Streszczenie treści zawartej na stronie nr. 8
viii Cyclades PM IPDU Installer/Administrator/User Guide
Streszczenie treści zawartej na stronie nr. 9
ix LIST OF TABLES List of Tables Table 1.1: Standalone Configuration Descriptions........................................................................... 2 Table 2.1: PM IPDU Shipping Box Contents and Description ......................................................... 5 Table 2.2: PM IPDU Optimum Installation Environment................................................................. 7 Table 2.3: Cyclades PM42 IPDU Callout Descriptions......................................................
Streszczenie treści zawartej na stronie nr. 10
x Cyclades PM IPDU Installer/Administrator/User Guide
Streszczenie treści zawartej na stronie nr. 11
1 CHAPTER Introduction 1 This installation, administration and user’s guide provides background information and procedures ® for installing, configuring and maintaining the Cyclades Power Management (PM) Intelligent Power Distribution Unit (IPDU) family. The Cyclades PM IPDU enables remote power control of servers and network gear. When used in ® conjunction with DSR switches or console servers, the PM IPDU delivers easier management capabilities and faster problem solving by integrating co
Streszczenie treści zawartej na stronie nr. 12
2 Cyclades PM IPDU Installer/Administrator/User Guide Integration with Avocent management products The PM IPDU can be combined with an ACS console server or DSR KVM switch to provide enhanced functionality. Please refer to the appropriate product documentation for more information on how to use the PM IPDU with your specific implementation. Hardware Configuration Options The PM IPDU may be used in one of three hardware configurations: • Standalone – Managed independently of any other h
Streszczenie treści zawartej na stronie nr. 13
Chapter 1: Introduction 3 NOTE: The installation example displays the PM IPDU being connected with the RJ-45 to DB-9F adaptor that is shipped with the product. If the unit you are connected to does not have a DB-9M COM port, you may use a USB serial adaptor and connect to a USB port when possible. Daisy chained configuration In a daisy chained configuration, multiple PM IPDUs are connected to one another and managed by a single main PM IPDU. The PMs are linked together with RJ-45 cabl
Streszczenie treści zawartej na stronie nr. 14
4 Cyclades PM IPDU Installer/Administrator/User Guide
Streszczenie treści zawartej na stronie nr. 15
5 CHAPTER Installation 2 Getting Started Collect the following equipment prior to installing and configuring the PM IPDU in standalone configuration: • One or more RJ-45 to RJ-45 straight-through cables • An RJ-45 to DB-9F straight-through adaptor • A PC running a terminal emulation program Supplied with the PM IPDU Table 2.1: PM IPDU Shipping Box Contents and Description Description Purpose PM IPDU Quick Installation Guide (QIG) Basic installation guide in printed format. RJ-45 to RJ-45 7f
Streszczenie treści zawartej na stronie nr. 16
6 Cyclades PM IPDU Installer/Administrator/User Guide NOTE: The Cyclades PM 10i-32Au IPDU ships with an unterminated power cord. If necessary, contact Avocent Technical Support for guidelines on approved power plug installation. Optional outlet cable package The following cable packages may be ordered separately for the IEC PM IPDU models: • 8-outlet cables (C13 female to C14 male) • 10-outlet cables (C13 female to C14 male) Rack Mounting the PM IPDU You may mount the PM IPDU on a rack
Streszczenie treści zawartej na stronie nr. 17
Chapter 2: Installation 7 Installation environment When installing the PM IPDU, ensure that the following environment specifications are met. Table 2.2: PM IPDU Optimum Installation Environment Environment Factor Recommendation Temperature The manufacturer's maximum recommended ambient temperature for the PM IPDU is 122 ºF (50 ºC). Elevated Operating Ambient If the PM IPDU is installed in a closed or multi-unit rack assembly, the Temperature operating ambient temperature of the rack
Streszczenie treści zawartej na stronie nr. 18
8 Cyclades PM IPDU Installer/Administrator/User Guide 10 11 12 4 1 5 7 6 8 9 2 3 Figure 2.2: A Sample PM IPDU (PM42 Shown) Table 2.3: Cyclades PM42 IPDU Callout Descriptions Number/Letter Description 1 Outlet, IEC320-C13, 14 each for bank XY, YZ and XZ 2 RS-232 (IN) Port 3 MULTI (OUT) Port 4 Overload Reset Button 5 Three digit LED displays the current on Phase X, Y and Z in sequence, or the voltage across Phases X and Y, Y and Z, and X and Z in sequence 6 SCROLL button - manually toggles
Streszczenie treści zawartej na stronie nr. 19
Chapter 2: Installation 9 To daisy chain a PM IPDU: This procedure assumes that a main PM IPDU is already connected to a workstation or management appliance. 1. Connect one end of an RJ-45 cable to the OUT port of the main PM IPDU, which is connected to a workstation or management appliance. 2. Connect the other end of the RJ-45 cable to the IN port of the secondary Cyclades PM IPDU. 3. Repeat these steps until you have connected the desired number of PM IPDUs. Accessing the Console Us
Streszczenie treści zawartej na stronie nr. 20
10 Cyclades PM IPDU Installer/Administrator/User Guide power management hotkey (Ctrl+P by default) to activate a power management menu. Please refer to the appropriate product documentation for more information. To connect a PM IPDU to an Avocent DSR switch: Use the included RJ-45 cable adaptor to connect a PM IPDU to an Avocent DSR switch. 1. Plug the male end of the adaptor into the DSR switch’s SPC port. 2. Plug one end of a straightthrough CAT 5 cable into the female end of the adap