Streszczenie treści zawartej na stronie nr. 1
ADCP-61-471
Issue 4
June 2000
®
Soneplex Broadband System
Operation and Maintenance
Manual (V5.3)
1037961 Rev A
Streszczenie treści zawartej na stronie nr. 2
ADCP-61-471 • Issue 4 June 2000 Preface COPYRIGHT 2000, ADC Telecommunications, Inc. All Rights Reserved Printed in the U.S.A. REVISION HISTORY ISSUE DATE REASON FOR CHANGE 1st Edition, Issue 1 10/1995 Original. 1st Edition, Issue 2 03/1996 Added Version 5.1 software update and corrected typographical errors. 1st Edition, Issue 3 01/1998 Corrected typographical and artwork errors, updated format (added TOC 3rd level, alphabetical task list, and expanded related manuals listing), changed pa
Streszczenie treści zawartej na stronie nr. 3
ADCP-61-471 Issue 4 June 2000 Preface LIST OF CHANGES The technical changes incorporated into this issue are listed below. SECTION IDENTIFIER DESCRIPTION OF CHANGE — Cover/Title page Removed list of contents. FM Related Publications Added new publications. FM List of Acronyms Added new acronyms and abbreviations. and Abbreviations 1 TAD-101 Turned specifications into a TAD. Combined Version D HLXC tables and Version E HLXC information into one table. — Various Changed “smartjack” to “NID”.
Streszczenie treści zawartej na stronie nr. 4
ADCP-61-471 Issue 4 June 2000 Preface Page iv 2000, ADC Telecommunications, Inc.
Streszczenie treści zawartej na stronie nr. 5
ADCP-61-471 Issue 4 June 2000 Preface TABLE OF CONTENTS Content Page FRONT MATTER ABOUT THIS MANUAL ...................................................................... ix RELATED PUBLICATIONS .................................................................... ix ADMONISHMENTS..........................................................................x GENERAL SAFETY PRECAUTIONS................................................................x FCC COMPLIANCE STATEMENT .....................
Streszczenie treści zawartej na stronie nr. 6
ADCP-61-471 Issue 4 June 2000 Preface TABLE OF CONTENTS Content Page SECTION 2 OPERATION AND MAINTENANCE (continued) ALARMS PROCEDURES .............................................................. NTP-006 APU INSTALLATION AND TESTING....................................................... DLP-503 ASSIGNMENT RECORDS.............................................................. DLP-523 CHASSIS INSPECTION ............................................................... DLP-501 CIRCUIT ID DISPL
Streszczenie treści zawartej na stronie nr. 7
ADCP-61-471 Issue 4 June 2000 Preface TABLE OF CONTENTS Content Page SECTION 2 OPERATION AND MAINTENANCE (continued) LOOPBACK PROCESS DESCRIPTION ..................................................... TAD-102 LOOPBACK STATUS/COMMANDS ....................................................... DLP-541 MAINTENANCE PHILOSOPHY.......................................................... TAD-100 MAINTENANCE PROCEDURES.......................................................... NTP-005 MENU SECURITY EDITI
Streszczenie treści zawartej na stronie nr. 8
ADCP-61-471 Issue 4 June 2000 Preface TABLE OF CONTENTS Content Page SECTION 2 OPERATION AND MAINTENANCE (continued) SHELF STATUS DISPLAY ............................................................. DLP-545 SPECIFICATIONS................................................................... TAD-101 STREAKER INSTALLATION AND TESTING .................................................. DLP-571 SYSTEM COMPONENTS INSPECTION ..................................................... DLP-500 SYSTEM OR CI
Streszczenie treści zawartej na stronie nr. 9
ADCP-61-471 Issue 4 June 2000 Preface ABOUT THIS MANUAL This manual describes how to operate and maintain the ADC Soneplex Broadband system (V5), which is a DS1-based multiplexer with an interface that is compatible with DS3 networks. It is specifically designed for use as a hub to distribute DS1 HiCap circuits for local access. For a complete description of the Soneplex Broadband system, refer to Soneplex Description, Design, and Application manual, listed under Related Publications in th
Streszczenie treści zawartej na stronie nr. 10
ADCP-61-471 Issue 4 June 2000 Preface ADMONISHMENTS Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments — in the form of Dangers, Warnings, and Cautions — must be followed at all times. These warnings are flagged by use of the triangular alert icon (seen below), and are listed in descending order of se
Streszczenie treści zawartej na stronie nr. 11
ADCP-61-471 Issue 4 June 2000 Preface FCC COMPLIANCE STATEMENT Class A The Soneplex Broadband system has been certified to comply with the requirements for class A computing devices per part 15 of the FCC regulations. Warning: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with limits for a Class A digital de
Streszczenie treści zawartej na stronie nr. 12
ADCP-61-471 Issue 4 June 2000 Preface TA-NWT-001210 Generic Requirements for High Bit Rate Digital Subscriber Lines (HDSL), Issue 1, October 1991. TR-TSY-000827 OTGR: Generic Operations Interfaces: Non-OSI Communications Architecture, Sections 11.1 and 11.3 (Issue 1). LIST OF ACRONYMS AND ABBREVIATIONS The acronyms and abbreviations used in this manual are detailed in the following list: ADM Add/Drop Multiplexer AIS Alarm Indication Signal Alarm ALM Alternate Mark Inversion AMI ANSI Americ
Streszczenie treści zawartej na stronie nr. 13
ADCP-61-471 Issue 4 June 2000 Preface DFMS Digital Facility Maintenance System DLP Detailed Level Procedure (TOP term) DLX DS1 Loop Extender module (BB system only) DS1 Digital Signal - Level 1 DS2 Digital Signal - Level 2 DS3 Digital Signal - Level 3 DS3 Multiplexer module DS3 MUX Digital Signal Cross-Connect DSX Data Terminal Equipment DTE ESD Electrostatic Discharge ESF Extended Super Frame EV Event EXT External EXZ Excessive Zeros FCC Federal Communications Commission FE Far End FEND F
Streszczenie treści zawartej na stronie nr. 14
ADCP-61-471 Issue 4 June 2000 Preface MON Monitor MPU Main Processor Unit MUX Multiplexer MXP DS3 MUX Protect slot MXW DS3 MUX Working slot Near End NE Network Element NE NEND Near End NID Network Interface Device NMA Bell Network Monitoring and Analysis System NRZ Non-Return-to-Zero NTP Non-Trouble Clearing Procedure (TOP term) OAM&P Operation, Administration, Maintenance & Provisioning ODS2 Optical Digital Signal 2 OOF Out Of Frame OOS Out Of Service OR a type of Boolean operator OSS Ope
Streszczenie treści zawartej na stronie nr. 15
ADCP-61-471 Issue 4 June 2000 Preface SNR Signal-to-Noise Ratio SONET Synchronous Optical Network SPX Soneplex St Status STAT Status Streaker module STK Switched Virtual Circuit SVC T Tip TAD Trouble Analysis Data (TOP term) TAP Trouble Analysis Procedure (TOP term) TASC Telecommunications Alarm Surveillance and Control TAU Test Access Unit TBOS Telemetry Byte Oriented Serial TID Target Identifier TL1 Transaction Language 1 TOP Task Oriented Process TSGR Transport Systems Generic Requireme
Streszczenie treści zawartej na stronie nr. 16
INTRODUCTION
Streszczenie treści zawartej na stronie nr. 17
ADCP-61-471 • Issue 4 June 2000 Section 1: Introduction SECTION 1: INTRODUCTION Content Page 1 GENERAL......................................................................... 1-1 2 USING THE CRAFT INTERFACE .......................................................... 1-1 3 EDITING FIELDS .................................................................... 1-3 3.1 Cursor ..................................................................... 1-3 3.2 Arrow Keys....................................
Streszczenie treści zawartej na stronie nr. 18
ADCP-61-471 Issue 4 June 2000 Section 1: Introduction Figure 1-1. Soneplex Broadband (V5) Craft Interface Menu Tree Page 1-2 2000, ADC Telecommunications, Inc. MAIN MENU DISPLAY UNIT SYSTEM SYSTEM SYSTEM PERFORMANCE ALARMS STATUS CONFIGURATION ADMINISTRATION CONFIGURATION MAINTENANCE MONITORING FORCE/APS ACTIVE ALARMS SHELF STATUS DS3 MUX CONFIG. USER ACCOUNTS SYSTEM TID/DATE/TIME PM CONFIG. COMMAND ALARM SUMMARY DS3 MUX STATUS ODS2 CONFIG. MENU SECURITY SERIAL PORT CONFIG. DS1 PM CONFIG
Streszczenie treści zawartej na stronie nr. 19
ADCP-61-471 Issue 4 June 2000 Section 1: Introduction A logon is required to gain access to the Craft Interface. The logon remains active until either the operator logs off or a user-selectable period of keyboard inactivity is exceeded. The default time-out period is 30 minutes. Passwords are used to limit access to the system. When you enter your assigned User Name, the Soneplex Broadband system will request a password. When you enter your assigned password, the Main Menu appears. It incl
Streszczenie treści zawartej na stronie nr. 20
ADCP-61-471 Issue 4 June 2000 Section 1: Introduction 3.4 Space Bar Pressing the space bar when the cursor is in a toggle field changes the item at the cursor. If the item is selected from a list of options, pressing the space bar brings up the next choice. 3.5 “R” Key If you press the “R” key by itself when you are in a toggle field, the selection will revert to its previous value. 3.6 Control Key Special functions are activated by pressing the Control key and another key at the same tim