Streszczenie treści zawartej na stronie nr. 1
instruction manual
NetLinx Integrated
Controllers
(NI-2000, NI-3000, and NI-4000)
NetLinx Central Controllers and Cards
Streszczenie treści zawartej na stronie nr. 2
AMX Limited Warranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: • Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. � Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series product
Streszczenie treści zawartej na stronie nr. 3
Table of Contents Table of Contents Introduction ...............................................................................................................1 NI-2000 Specifications ...................................................................................................... 1 NI-3000 Specifications ...................................................................................................... 5 NI-4000 Specifications ...........................................................
Streszczenie treści zawartej na stronie nr. 4
Table of Contents Installation and Upgrading ....................................................................................29 Installing NetLinx Control Cards (NI-4000 Only)............................................................. 29 Setting the NetLinx Control Card Addresses (NI-4000 Only).......................................... 30 Device:Port:System (D:P:S)............................................................................................ 30 Removing NetLinx Control Cards
Streszczenie treści zawartej na stronie nr. 5
Table of Contents Security tab - Modify User page............................................................................................. 64 Security tab - User Directory Associations page.................................................................... 65 Security tab - SSL Server Certificate page ............................................................................ 67 Security tab - Export Certificate Request page..................................................................
Streszczenie treści zawartej na stronie nr. 6
Table of Contents Accessing the Security configuration options.................................................................. 94 Option 1 - Set system security options for NetLinx Master (Security Options Menu) ............ 95 Option 2 - Display system security options for NetLinx Master.............................................. 96 Option 3 - Add user................................................................................................................ 96 Option 4 - Edit User....
Streszczenie treści zawartej na stronie nr. 7
Introduction Introduction NetLinx Integrated Master Controllers can be programmed to control RS-232/422/485, Relay, IR/ Serial, and Input/Output devices through the use of both the NetLinx programming language and the NetLinx Studio application (version 2.2 or higher). Another key feature of this products is the ability to easily access the configuration switches without having to remove a cover plate. NetLinx Integrated Master Controller Features NI-2000 � 1 RS-232 Program por
Streszczenie treści zawartej na stronie nr. 8
Introduction FIG. 1 NI-2000 NetLinx Integrated Controller (front view) RS-232/422/485 TX/RX LEDs (red/yellow) Link/Active-Status-Output-Input Relay LEDs (red) IR/Serial LEDs (red) I/O LEDs (yellow) Front ICSNet (2) AXLink LED (green) RS-232/422/485 (Ports 1-3) Rear ICSHub Out AXLink port Ethernet Relays IR/Serial (Ports 5-8) (Port 4) DIP I/O (Port 9) Program PWR switch port ID Pushbutton FIG. 2 NI-2000 front and rear panel components NI-2000 Specifications Dimensions (HWD): � 3.47" x 17.00" x
Streszczenie treści zawartej na stronie nr. 9
Introduction NI-2000 Specifications (Cont.) Front Panel Components: LINK/ACT � Green LED lights when the Ethernet cable is connected and an active link is established. This LED also blinks when receiving Ethernet data packets. Status � Green LED lights to indicate that the system is programmed and communicating properly. Output � Red LED lights when the Controller transmits data, sets channels On/Off, sends data strings, etc. Input � Yellow LED blinks when the Contro ller receives data from b
Streszczenie treści zawartej na stronie nr. 10
Introduction NI-2000 Specifications (Cont.) Digital I/O (Port 9) � Four-channel binary I/O port for contact closure � Each input is capable of voltage sensing. Input format is software selectable. � Interactive power sensing for IR ports � Channel range = 1-4 � All inputs are assigned to respective IR/Serial ports for "automatic" power control through the use of software commands. Power control is provided via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.). � Contact closure b
Streszczenie treści zawartej na stronie nr. 11
Introduction NI-2000 Specifications (Cont.) Ethernet Link/Activity LED � LEDs show communi cation activity, connections, speeds, and mode information: SPD-speed - Yellow LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps. L/A-link/activity - Green LED lights On when the Ethernet cables are connected/terminated correctly and blinks when receiving Ethernet data packets. AXlink LED � One green LED indicates the state of the AXlink connector port. � Norma
Streszczenie treści zawartej na stronie nr. 12
Introduction FIG. 3 NI-3000 NetLinx Integrated Controller (front view) RS-232/422/485 TX/RX LEDs (red/yellow) Link/Active-Status-Output-Input Relay LEDs (red) IR/Serial LEDs (red) I/O LEDs (yellow) Front ICSNet (2) AXLink LED RS-232/422/485 (Ports 1-7) ICSHub Out (green) Rear AXLink Relays IR/Serial (Ports 9-16) Ethernet port (Port 8) Program DIP I/O (Port 17) switch port PWR ID Pushbutton FIG. 4 NI-3000 front and rear panel components 6 NetLinx Integrated Controllers
Streszczenie treści zawartej na stronie nr. 13
Introduction NI-3000 Specifications (Cont.) Dimensions (HWD): � 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm) � 2 RU (rack unit) high Power requirements: � 900 mA @ 12 VDC Memory: � 32 MB SDRAM � 1 MB of Non-volatile Flash Compact Flash: � 32 MB Card (upgradeable). Refer to the Optional Accessories section on page 10 for more information. Weight: � 4.55 lbs (2.06 kg) Enclosure: � Metal with black matte finish Front Panel Components: LINK/ACT � Green LED lights when the Ethernet cable is
Streszczenie treści zawartej na stronie nr. 14
Introduction NI-3000 Specifications (Cont.) Rear Panel Components: RS-232/422/485 (Ports 1 -7) � Seven RS-232/422/485 control ports using DB9 (male) connectors with XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and 300-115,200 baud. � Channel range = 1-255 � Channels 1-254 provide feedback � Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a 'CTSPSH' command was sent to the port � Output data format for each port is selected via software � S
Streszczenie treści zawartej na stronie nr. 15
Introduction NI-3000 Specifications (Cont.) IR/Serial (Ports 9-16) � Eight IR/Serial control ports support high-frequency carriers up to 1.142 MHz � Each output is capable of two electrical formats: IR or Serial � Eight IR/Serial data signals can be generated simultaneously � Channel range = 1-32,767 � Channels 1-128 (output): IR commands � Channels 129-253: used as reference channels � Channel 254 (feedback): Power Fail (used with 'PON' and 'POF' commands) � Channel 255 (feedback): Power stat
Streszczenie treści zawartej na stronie nr. 16
Introduction NI-3000 Specifications (Cont.) Optional Accessories: � 2 Pin Black Male Phoeni x Connector (3.5mm) (41-5026) � CC-NIRC IR cables ( FG10-000-11) � CC-NSER IR/Serial cables ( FG10-007-10) � CSB Cable Support Bracket ( FG517) � NCK, NetLinx Connector Kit ( FG2902) � NI-3000 Quick Start Guide (93-2105-01) � PSN2.8 12 VDC power supply ( FG423-17) � PSN6.5 12 VDC power supply ( FG423-41) � STS, Serial To Screw Terminal ( FG959) � Upgrade Compact Flash (factory programmed with firmware):
Streszczenie treści zawartej na stronie nr. 17
Introduction RS-232/422/485 TX/RX LEDs (red/yellow) Link/Active-Status-Output-Input Relay LEDs (red) IR/Serial LEDs (red) NetLinx Card I/O LEDs (yellow) slots (1-4) Front ICSNet (2) AXLink LED RS-232/422/485 (Ports 1-7) ICSHub Out (green) Rear AXLink port Relays Ethernet I/O (Port 17) IR/Serial (Ports 9-16) (Port 8) DIP switch Program port PWR CardFrame DIP Slot 1-4 connectors switch ID Pushbutton FIG. 6 NI-4000 front and rear panel components NI-4000 Specifications Dimensions (HWD): � 5.21" x
Streszczenie treści zawartej na stronie nr. 18
Introduction NI-4000 Specifications (Cont.) Relay LEDs � Eight red LEDs light to indicate the rear relay channels 1-8 are active (closed) � These LEDs reflect the state of the relay on Port 8 � If the relay is engaged = LED On and if the relay is Off = LED Off IR/Serial LEDs � Eight red LEDs light to indicate the rear IR/Serial channels 1-8 are transmitting control data on Ports 9-16 � LED indictor for each IR port remains lit for the length of time that IR/Serial data is being generated I/O
Streszczenie treści zawartej na stronie nr. 19
Introduction NI-4000 Specifications (Cont.) Digital I/O (Port 17) � Eight-channel binary I/O port for contact closure � Each input is capable of voltage sensing. Input format is software selectable. � Interactive power sensing for IR ports � Channel range = 1-8 � All inputs are assigned to respective IR/Serial ports for "automatic" power control through the use of software commands. Power control is provided via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.). � Contact closure
Streszczenie treści zawartej na stronie nr. 20
Introduction NI-4000 Specifications (Cont.) CardFrame Number � Sets the starting address for the Control Cards in the CardFrame.(Factory DIP switch default CardFrame DIP switch value = 0). � The Control Card address range is 1-3064. NetLinx Control Card � Four 20-pin (male) connectors t hat bridge the gap between the Control connectors (1-4) Cards in the CardFrame and external equipment. Included Accessories: � Two CC-NIRC IR Emitters ( FG10-000-11) � One 10-pin 3.5 mm mini-Phoenix (f emale