Streszczenie treści zawartej na stronie nr. 1
REJ10J0964-0100(T)
M306H7T3-RPD-E
User’s Manual
Emulation Pod for M16C/6H Group M306H7
Rev.1.00
Sep. 01, 2005
Streszczenie treści zawartej na stronie nr. 2
Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with ap- propriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of non- fl
Streszczenie treści zawartej na stronie nr. 3
M306H7T3-RPD-E User’s Manual Preface Preface The M306H7T3-RPD-E is an emulation pod for the M16C/6H Group M306H7 of 16-bit MCUs. It is used with a PC4701 emulator (excluding the PC4700L and PC4701L). This user's manual mainly describes specifications of the M306H7T3-RPD-E emulation pod and how to setup it. For details on the emulator main unit and emulator debugger, which are used with the M306H7T3-RPD-E, refer to each product's user's manual or online manual. All the components of
Streszczenie treści zawartej na stronie nr. 4
M306H7T3-RPD-E User’s Manual Important Important Before using this product, be sure to read this user’s manual carefully. Keep this user’s manual, and refer to this when you have questions about this product. Emulator: The emulator in this document refers to the following products that are manufactured by Renesas Technology Corp.: (1) PC4701 main unit (2) Emulation pod (3) Package converter board for connecting the user system The emulator herein does not include the customer’s
Streszczenie treści zawartej na stronie nr. 5
M306H7T3-RPD-E User’s Manual Important Usage restrictions: This emulator has been developed as a means of supporting system development by users. Therefore, do not use it as a device used for equipment-embedded applications. Also, do not use it for developing the systems or equipment used for the following purposes either: (1) Transportation and vehicular (2) Medical (equipment where human life is concerned) (3) Aerospace (4) Nuclear power control (5) Undersea repeater If you are con
Streszczenie treści zawartej na stronie nr. 6
M306H7T3-RPD-E User’s Manual Precautions for Safety Precautions for Safety Definitions of Signal Words In both the user’s manual and on the product itself, several icons are used to insure proper handling of this product and also to prevent injuries to you or other persons, or damage to your properties. This chapter describes the precautions which should be taken in order to use this product safely and properly. Be sure to read this chapter before using this product. This symbol
Streszczenie treści zawartej na stronie nr. 7
M306H7T3-RPD-E User’s Manual Precautions for Safety 警告警告 WARNING Warnings for AC Power Supply: If the attached AC power cable does not fit the receptacle, do not alter the AC power cable and do not plug it forcibly. Failure to comply may cause electric shock and/or fire. Use an AC power cable which complies with the safety standard of the country. Do not touch the plug of the AC power cable when your hands are wet. This may cause electric shock. This product is connected s
Streszczenie treści zawartej na stronie nr. 8
M306H7T3-RPD-E User’s Manual Precautions for Safety 注意注意 CAUTION Cautions to Be Taken for Turning On the Power: Turn ON the power of the emulator and user system as simultaneously as possible. Turn OFF the power of the emulator and user system as simultaneously as possible. Do not leave either the emulator or user system powered on, because of leakage current the internal circuits may be damaged. When turning ON the power again after shutting OFF the power, wait about 10 second
Streszczenie treści zawartej na stronie nr. 9
M306H7T3-RPD-E User’s Manual Contents Contents Page Preface......................................................................................................................................................................... 3 Related manuals.......................................................................................................................................................... 3 Important.................................................................................
Streszczenie treści zawartej na stronie nr. 10
M306H7T3-RPD-E User’s Manual Contents Page 3. Usage (How to Use the Emulator Debugger)........................................................................................................ 48 3.1. Making an MCU File .................................................................................................................................... 48 3.2 Setting the Work Area...................................................................................................................
Streszczenie treści zawartej na stronie nr. 11
M306H7T3-RPD-E User’s Manual User Registration User Registration When you have purchased the emulator presented in this user's manual, please be sure to register it. As the H/W Tool Customer Registration Sheet is included with this product, fill it in and FAX it to your local distributor or email the same contents to the following address. Your registered information is used for only after-sale services, and not for any other purposes. Without user registration, you will not be able to
Streszczenie treści zawartej na stronie nr. 12
M306H7T3-RPD-E User’s Manual Terminology Terminology Some specific words used in this user's manual are defined as follows: Emulator main unit (Hereafter PC4701) This means a generic name for emulators for M16C, 7700, 740 Families. Take note of the fact that the M306H7T3-RPD-E (this product) does not support the PC4701L and PC4700L emulators. For details on specific models of PC4701, visit the Renesas Tools Homepage at http://www.renesas.com/en/tools. Emulation pod This means the emu
Streszczenie treści zawartej na stronie nr. 13
M306H7T3-RPD-E User’s Manual 1. Outline 1. Outline This chapter describes the package components, the system configuration and the preparation for using this product for the first time. 1.1 Package Components The M306H7T3-RPD-E package consists of the following items. When unpacking it, check to see if your M306H7T3-RPD-E contains all of these items. Table 1.1 Package components Item Quantity M306H7T3-RPD-E emulation pod 1 FLX120-RPD flexible cable for connecting PC4701 1 M3080
Streszczenie treści zawartej na stronie nr. 14
M306H7T3-RPD-E User’s Manual 1. Outline 1.2 Other Tool Products Required for Development To bring forward programs development on the M16C/6H Group M306H7, the products listed below are necessary in addition to those contained package above. Get them separately. Table 1.2 Other tool products required for development Product Product name Notes Emulator main unit PC4701 - M16C PC4701 Emulator Debugger Emulator debugger Included with the PC4701 M3T-PD30 M3T-100LCC-DMS + M3T-DIREC
Streszczenie treści zawartej na stronie nr. 15
M306H7T3-RPD-E User’s Manual 1. Outline 1.3 System Configuration 1.3.1 System Configuration Figure 1.1 shows a configuration of the PC4701 system. (6) Host machine Interface cable (5) Emulator main unit Host machine (2) Flexible cable connecting PC4701 (1) Emulation pod (3) Flexible cable connecting user system (4) Pitch converter board for connecting user system (7) User system Figure 1.1 System configuration (1) Emulation pod M306H7T3-RPD-E (this product) Emulation pod fo
Streszczenie treści zawartej na stronie nr. 16
M306H7T3-RPD-E User’s Manual 1. Outline 1.3.2 Names and Functions of the PC4701 Front Panel LEDs Figure 1.2 shows the names of the LEDs on the front panel of the emulator. Target status LEDs STATUS OF TARGET POWER POWER SAFE CLOCK System status LEDs ERROR RESET STATUS OF RUN SYSTEM HALT RESET HIGH PERFORMANCE EMULATOR Figure 1.2 Names of the LEDs on the front panel of the PC4701 (1) System Status LEDs The system status LEDs indicate the emulator PC4701's power supply, firmwar
Streszczenie treści zawartej na stronie nr. 17
M306H7T3-RPD-E User’s Manual 1. Outline (2) Target Status LEDs The target status LEDs indicate the target MCU's operating status and target board's power supply. Table 1.4 lists the definition of each target status LED. Table 1.4 Definitions of the target status LEDs Name Status Meaning ON Power is supplied to the user system. POWER OFF Power is not supplied to the user system. ON Target MCU clock is oscillating. CLOCK OFF Target MCU clock is not oscillating. ON Target MCU is
Streszczenie treści zawartej na stronie nr. 18
M306H7T3-RPD-E User’s Manual 1. Outline 1.4 Specifications Tables 1.5 and 1.6 list the specifications of the M306H7T3-RPD-E. Table 1.5 M306H7T3-RPD-E specifications (1/2) Item Description Applicable MCU M16C/6H Group M306H7 Usable MCU mode Single-chip mode Emulation Memory 1MB VCC2=4.0V--5.5V, VCC1=3.0V--VCC2 (Xin: when operating without division) VCC2=2.9V--5.5V, VCC1=2.9V--VCC2 (Xin: when operating in a Applicable power supply divide-by-16 or 8-mode) VCC2=2.0V--5.5V, VCC1=2.0
Streszczenie treści zawartej na stronie nr. 19
M306H7T3-RPD-E User’s Manual 1. Outline Table 1.6 M306H7T3-RPD-E specifications (2/2) Item Description Connecting the user system 100-pin LCC socket 1 M30800T-PTC (included) (see “2.8 Connecting the User System” + IC61-1004-051 (included) on page 31) 100-pin 0.65-mm-pitch QFP 1 M30800T-PTC (included) (PRQP0100JB-A) + M3T-100LCC-DMS (not included) + M3T- DIRECT100S (not included) 2 M30800T-PTC (included) + M3T-100LCC-DMS (not included) + M3T-DUMMY100S (not included) 3 M30800
Streszczenie treści zawartej na stronie nr. 20
M306H7T3-RPD-E User’s Manual 2. Setup 2. Setup This chapter describes the preparation for using this product, the procedure for starting up the emulator and how to change settings. 2.1 Flowchart of Starting Up the Emulator The procedure for starting up the emulator is shown in Figure 2.1. For details, refer to each section hereafter. And, when the emulator does not start up normally, refer to “5. Troubleshooting” (page 80). Check the package components. Refer to “1.1 Package