Streszczenie treści zawartej na stronie nr. 1
Cat. No. W343-E1-07
SYSMAC
CS/CJ Series
CS1W-ETN01 (10Base-5)
CS1W-ETN11 (10Base-T)
CJ1W-ETN11 (10Base-T)
Ethernet Units
OPERATION MANUAL
Streszczenie treści zawartej na stronie nr. 2
CS1W-ETN01 (10Base-5) CS1W-ETN11 (10Base-T) CJ1W-ETN11 (10Base-T) Ethernet Units Operation Manual Revised January 2008
Streszczenie treści zawartej na stronie nr. 3
iv
Streszczenie treści zawartej na stronie nr. 4
Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or dam- age to property. !DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Additional
Streszczenie treści zawartej na stronie nr. 5
vi
Streszczenie treści zawartej na stronie nr. 6
TABLE OF CONTENTS PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii 2 General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii 3 Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii 4 Operating Environment Pre
Streszczenie treści zawartej na stronie nr. 7
TABLE OF CONTENTS SECTION 4 System Setup and Memory Allocations. . . . . . . . . . . . . . 57 4-1 Allocated Words . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 4-2 CPU Bus Unit System Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 4-3 CIO Area Allocations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 4-4 DM Area Allocations. . . . . . . . . . . . .
Streszczenie treści zawartej na stronie nr. 8
TABLE OF CONTENTS SECTION 10 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 10-1 Troubleshooting with Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 10-2 Error Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 10-3 Error Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 10-4
Streszczenie treści zawartej na stronie nr. 9
Streszczenie treści zawartej na stronie nr. 10
About this Manual: This manual describes the installation and operation of the SYSMAC CS-series CS1W-ETN01 (10Base-5) and CS1W-ETN11 (10Base-T) Ethernet Units and the CJ-series CJ1W-ETN11 (10Base-T) Ethernet Unit, and includes the sections described on the next page. An Ethernet Unit is classified and treated as a CPU Bus Unit in PC processing. This manual is based on Ethernet* networks comprised of Ethernet Unit nodes and UNIX* host com- puter nodes. Although details can vary, theoretically any
Streszczenie treści zawartej na stronie nr. 11
About this Manual, Continued Name Cat. No. Contents SYSMAC CS/CJ-series W341-E1-@ Provides information on how to program and operate CS/CJ-series PCs C200H-PRO27-E, CQM1H-PRO01-E using a Programming Console. CQM1-PRO01-E Programming Consoles Operation Manual SYSMAC CS/CJ-series W342-E1-@ Describes the C-series (Host Link) and FINS communications com- CS1G/H-CPU@@-EV1, CJ1G-CPU@@, mands used with CS/CJ-series PCs. CS1W-SCB21-V1/41-V1, CS1W-SCU21, CJ1W-SCU41 Communications Commands Reference
Streszczenie treści zawartej na stronie nr. 12
Read and Understand this Manual Please read and understand this manual before using the product. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON- INFRINGEME
Streszczenie treści zawartej na stronie nr. 13
Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the
Streszczenie treści zawartej na stronie nr. 14
Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request.
Streszczenie treści zawartej na stronie nr. 15
xvi
Streszczenie treści zawartej na stronie nr. 16
PRECAUTIONS This section provides general precautions for using the CS/CJ-series Programmable Controllers (PCs) and related devices. The information contained in this section is important for the safe and reliable application of Programmable Controllers. You must read this section and understand the information contained before attempting to set up or operate a PC system. 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii 2 General
Streszczenie treści zawartej na stronie nr. 17
Intended Audience 1 1 Intended Audience This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). • Personnel in charge of installing FA systems. • Personnel in charge of designing FA systems. • Personnel in charge of managing FA systems and facilities. 2 General Precautions The user must operate the product according to the performance specifica- tions described in the operation manuals. Before using the p
Streszczenie treści zawartej na stronie nr. 18
Operating Environment Precautions 4 !Caution Execute online edit only after confirming that no adverse effects will be caused by extending the cycle time. Otherwise, the input signals may not be readable. 4 Operating Environment Precautions !Caution Do not operate the control system in the following places: • Locations subject to direct sunlight. • Locations subject to temperatures or humidity outside the range specified in the specifications. • Locations subject to condensation as the result of
Streszczenie treści zawartej na stronie nr. 19
Application Precautions 5 Mounting or dismounting I/O Units, CPU Units, Inner Boards, or any other Units. Assembling the Units. Setting DIP switches or rotary switches. Connecting cables or wiring the system. !Caution Failure to abide by the following precautions could lead to faulty operation of the PC or the system, or could damage the PC or PC Units. Always heed these precautions. • Fail-safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, o
Streszczenie treści zawartej na stronie nr. 20
Conformance to EC Directives 6 • Do not pull on the communications cables or bend the communications cables beyond their natural limit. Doing either of these may break the cables. • Do not place objects on top of the communications cables or other wiring lines. Doing so may break the cables. • Before touching a Unit, be sure to first touch a grounded metallic object in order to discharge any static built-up. Not doing so may result in malfunc- tion or damage. When transporting or storing Units