Streszczenie treści zawartej na stronie nr. 1
Models
FR3060, FR3100
FR3060/V4, FR3060/V8
FR3100/V4, FR3100/V8
User Guide
Streszczenie treści zawartej na stronie nr. 2
User Guide 88302203 Revision D MultiFRAD 3000-Series (Model Numbers FR3060, FR3100, FR3060/V4, FR3060/V8, FR3100/V4, FR3100/V8) This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved. Copyright © 1999, by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or
Streszczenie treści zawartej na stronie nr. 3
Contents Chapter 1 - Introduction and Description Introduction ................................................................................................................................................ 6 Preview of this Guide ................................................................................................................................. 7 Front Panel Description ................................................................................................................
Streszczenie treści zawartej na stronie nr. 4
Changing Voice/Fax Channel Parameters ............................................................................................... 55 Interface ............................................................................................................................................. 55 Voice/Fax ........................................................................................................................................... 56 Regional ..............................................
Streszczenie treści zawartej na stronie nr. 5
Chapter 1 - Introduction and Description
Streszczenie treści zawartej na stronie nr. 6
MultiFRAD 3000-Series User Guide Introduction Welcome to Multi-Tech's new MultiFRAD 3000 series, a Frame Relay Access Device (FRAD) that encapsulates data streams from the voice/fax channels, data channels, and LAN devices into frame relay frames. The MultiFRAD 3000 series contains six or ten syncronous or asynchronous data channels, four or eight Voice/Fax channels, a 10M bps Ethernet port, and a composite link that connects to a common carrier frame relay network service, private frame relay n
Streszczenie treści zawartej na stronie nr. 7
Chapter 1 - Introduction and Description Preview of this Guide This User Guide describes the MultiFRAD and details how to install and configure it. The information contained in each chapter is as follows: Chapter 1 - Introduction and Description Chapter 1 describes the MultiFRAD including front panel descriptions, back panel connectors, and relevant technical specifications. Chapter 2 - Installation Chapter 2 provides information on unpacking and cabling your MultiFRAD. Safety Warnings are det
Streszczenie treści zawartej na stronie nr. 8
MultiFRAD 3000-Series User Guide Front Panel Description The front panel of the MultiFRAD contains groups of LEDs that provide the information on the composite link activity, LAN, data channels, and Voice/Fax channel activity, and the general status of the MultiFRAD.
!
" & &+ )* & &( &' ' & &+ )* & &( &' ' & &+ )* & &( &' ' & &+ )* & &( &' '
#
Streszczenie treści zawartej na stronie nr. 9
Chapter 1 - Introduction and Description Channels 1 and 2 V35 V.35 Interface. This indicator lights when the channel is configured for a V.35 interface. XMT Transmit. This indicator blinks when the channel is receiving data to be transmitted on the link or over IP. RCV Receive. This indicator blinks when the channel is transmitting data received from the link. Channels 3 through 10 XMT Transmit. This indicator blinks when the channel is receiving data to be transmitted on the link or over IP
Streszczenie treści zawartej na stronie nr. 10
MultiFRAD 3000-Series User Guide Back Panel Description +4)
+4)
+4)
+4)
& & & & 522), 522), 522), 522), ! " 42() 2, +0+4() )* &+ & )* &+ & )* &+ & )* &+ & ,423 +24(+ &( +4)
+4)
+4)
+4)
& & & & 522), 522), 522), 522), # $ % (%9 '2 4 %/)( +20+ ( 522),% 522), 522),!
Streszczenie treści zawartej na stronie nr. 11
Chapter 1 - Introduction and Description Channels 3 - 10 Connectors These DB-25 female connectors are used to connect the MultiFRAD to channel devices. These connections can be to either asynchronous or HDLC synchronous RS-232 data equipment such as multiplexers. Voice/Fax Channels 1 - 8 Connectors E&M Use the E&M connector to connect the MultiFRAD Voice/Fax channel to the E&M connector on an analog PBX (Private Branch eXchange) trunk when linking two PBX’s together. The E&M connector is an RJ
Streszczenie treści zawartej na stronie nr. 12
MultiFRAD 3000-Series User Guide Technical Specifications Provides access to frame relay networks for SLIP, PPP, async and HDLC sync devices. Trunk and Data ports may be configured as EIA-232 or V.35 Trunk Speeds up to T1/E1 synchronous 4MB DRAM 16MB of flash memory Ethernet Port One Ethernet Interface - 10Base-T (twisted Pair) RJ-45 connector Command Port Single 19.2K bps asynchronous Command Port with a DB-25 female connector Composite Link (external) Access Rate: 1.544M bps (T
Streszczenie treści zawartej na stronie nr. 13
Chapter 2 - Installation
Streszczenie treści zawartej na stronie nr. 14
MultiFRAD 3000-Series User Guide Introduction This chapter guides you through the unpacking and installation of your MultiFRAD. The installation procedure, provides step by step instructions on cabling and powering-on the MultiFRAD. Chapter 3 provides instructions on loading and configuring the MultiFRAD software. Unpacking your MultiFRAD 3000 Remove all items from the box. Your shipping box should contain the MultiFRAD, a power supply, cables, software and manual diskettes, and a MultiFRAD
Streszczenie treści zawartej na stronie nr. 15
Chapter 2 - Installation Valid Voice/Fax Channels The following are the only valid Voice/Fax channels that can be made at this time: FXS to FXS FXS to FXO FXS to E&M E&M to E&M For example, the FXS configuration at the local site can talk to an FXO configuration at the remote site. Cabling your MultiFRAD 3000 Cabling your MultiFRAD involves general cabling connections for all models, data channel connections, and Voice/Fax connections for models connecting to telephone equipment. The
Streszczenie treści zawartej na stronie nr. 16
MultiFRAD 3000-Series User Guide 2 Connect the MultiFRAD to the COM port on a PC. Plug the DB-25 male end of your serial cable from your PC into the Command Port connector on the back of the MultiFRAD. 3 Connect one end of an DB-25 (female) cable to the Ext. Composite Link Connector on the back of the MultiFRAD (as shown in Figure 3). Connect the other cable end to your T1 CSU/ DSU or compatible link device. 4 If you are connecting to a LAN, make the network connection by connecting an RJ-45 (U
Streszczenie treści zawartej na stronie nr. 17
Chapter 2 - Installation Voice/Fax Cable Connections NOTE: The E&M, FXS, and Ethernet ports are not designed to be connected to a Public Telecommunication Network. 6 If you are connecting a station device; e.g., analog telephone, fax machine, or Key Telephone System (KTS) to your MultiFRAD; connect one end of an RJ-11 phone cord to the Voice/Fax Channel 1 FXS connector on the back of the MultiFRAD and the other end to the station device. See Figure 5. +4)
+4)
+4)
+4)
&
Streszczenie treści zawartej na stronie nr. 18
MultiFRAD 3000-Series User Guide E&M Jumper Block Positioning Procedure A jumper block exists for each voice/fax channel. The jumper block is to the right of each set of channel jacks. The jumper block contains 8-pairs of pins. The jumper plug fits over three pairs of pins on the jumper block. The E&M type number is labeled on the pc board. The jumper plug needs to be centered on the E&M type number. Perform the following procedure to change E&M jumper position. 1 Ensure that power is remo
Streszczenie treści zawartej na stronie nr. 19
Chapter 3 - Software Loading and Configuration
Streszczenie treści zawartej na stronie nr. 20
MultiFRAD 3000-Series User Guide Introduction This chapter will guide you through the installation and initial configuration of the MultiFRAD software included in your shipping box. Chapter 4 will provide a more detailed description of the software and it’s features. Loading your Software The following loading procedure does not provide every screen or option in the process of installing the MultiFRAD software. The assumption is that a technical person is doing the installation and that a tho