Streszczenie treści zawartej na stronie nr. 1
TereScope700 and TereScope800
Wireless Optical Communication Links
Models TS700/100, TS700/155, TS700/G, TS800/155
User Man ual
Streszczenie treści zawartej na stronie nr. 2
WIRELESS OPTICAL COMMUNICATIONS User Manual Document Number ML48237 (4703700), Rev. 4.0 February 2006 MRV Communications, Inc. Web site: www. mrv.com
Streszczenie treści zawartej na stronie nr. 3
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Table of Contents S T ANDARDS Standards Compliance ............................................................................ i FCC Notice ............................................................................................... i CE Mark ................................................................................................... i Other Standards ........................................................
Streszczenie treści zawartej na stronie nr. 4
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Data/Signal Cabling .............................................................................. 24 For TS700/155, TS700/G, TS800/155, TS800/155-F............................24 For TS700/100.........................................................................................25 CH APTER 4 - BENCH TEST TS700/155, TS800/155, and TS800/155-F............................................ 26 TS700/100.................
Streszczenie treści zawartej na stronie nr. 5
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Standards Standards Compliance UL 1950; CSA 22.2 No 950; FCC Part 15 Class B; CE-89/336/EEC, 73/23/EEC FCC Notice WARNING: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipmen
Streszczenie treści zawartej na stronie nr. 6
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Other Standards 1. CISPR 22: 1993 AS/NZS 3548: 1995, Class B Joint Amendment No. 1: 1997, Joint Amendment No. 2: 1997 2. EN 60950+A1+A2+A3+A4+A11 ACA TS001-1997 AS/NZS 3260: 1993 A4: 1997 3. ITU G.703, G.704, G.706,G.736, G.737, G.738, G739, G740, G.775, G.823. MRV Laser Safety Certification The TereScope is designed, built, and tested to be eyesafe, even if the output beams are viewed directly, p
Streszczenie treści zawartej na stronie nr. 7
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l About this User Manual Audience This manual is intended for the user who wishes to install, operate, manage and troubleshoot the TereScope700 and TereScope800. Qualifications Users of this guide are expected to have: • Working knowledge of Electro-optical equipment • Working knowledge of LAN equipment (Layer 2 and 3) • A License to install equipment on buildings/elevated structures • A License to work with pow
Streszczenie treści zawartej na stronie nr. 8
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Safety Requirements All requirements stipulated in the safety laws of the country of installation must be abided by when installing the TereScopes. Caution! In addition, ensure that the requirements noted in this chapter are met in order to reduce risk of electrical shock and fire and to maintain proper operation. Before Installing Power: Ensure that all power to the TereScope is cut off. Specifically, d
Streszczenie treści zawartej na stronie nr. 9
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l casual passersby. Examples of restricted locations are: sides of buildings at sufficient heights, restricted rooftops, and telephone poles. This definition of a restricted location is in accordance with the proposed IEC 60825-I Part 12 requirements. • Avoid using controls, adjustments, or procedures other than those specified herein as they may result in hazardous radiation exposure. • Avoid prolonged eye contact wit
Streszczenie treści zawartej na stronie nr. 10
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Introduction CAREFULLY READ THE ENTIRE MANUAL BEFORE INSTALLING n InfraRed (IR) link allows connection without any cable between two distant sites. For that, two identical transceivers, each installed on one site and aligned to face each other, provide point-to-point connectivity. This A configuration makes possible data transfer from one terminal to the other through the air over an optical wavelength carrier,
Streszczenie treści zawartej na stronie nr. 11
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Chapter 1 The Product Caution! When handling the TereScope, take special care not to damage the polycarbonate window! Models 1 Table 1: Models of the TereScope Models Part Number Description TS700/100 TS100/A/FET/VS TereScope700 for Fast Ethernet 100Base-TX connectivity up to a distance of 360 m + Power-over-Ethernet option. TS700/155 TS155/A/YUW/VS TereScope700 for 1-155 Mbps connectivity up to a distance
Streszczenie treści zawartej na stronie nr. 12
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l S (for SingleMode) ‘U’ represents operating wavelength. Instead of U use one of the following: 8 (for 850 nm) 3 (for 1310 nm) 5 (for 1550 nm) ‘W’ represents connector type. Instead of W use one of the following: C (for SC) T (for ST) ‘FET’ (Fast ethernet) represents 100Base-TX with RJ45 connector ‘V’ represents existence/absence of Fusion. Instead of V use one of the following: V designates no built-in Fusi
Streszczenie treści zawartej na stronie nr. 13
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l 2. Back All models of the TereScope are SNMP manageable. SNMP monitoring can be performed using MRV’s MegaVision SNMP management application. A. TS700/155 (Standard Model) The TS700 supports Fast Ethernet, OC3, STM1, E3, and T3 protocols in the 34- 155 Mbps range. A special type of TS700 can be ordered that can be used for Open Protocol applications which ensures complete transparency (including all data in the r
Streszczenie treści zawartej na stronie nr. 14
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Back Panel Description Table 2: TS700/155 Standard Model Back Panel Controls, Interfaces, and Indicators Connectors Power Power source Terminal Block (Main or UPS) AC power supply (100 to 240 Vac) or DC power supply (24 to 60 Vdc) Fiber optic Fiber Optic interface for connection to the peripheral equipment. The standard interface is MM 1310nm SC connector; other interfaces are available upon request. Mana
Streszczenie treści zawartej na stronie nr. 15
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l B. TS800/155 Standard Model The TS800/155 supports most of the prevalent protocols in the 34-155 Mbps range. Support for a special protocol, which is not on the list, can be ordered after coordination with the factory. This model can be used for Open Protocol applications which ensures complete transparency (including all data in the range of 1-155 Mbps.) In this case, a maximum 2 dB of the power budget is lost.
Streszczenie treści zawartej na stronie nr. 16
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Selectors Data Rate Set the transmission rate of the transceiver (internal (DIP Switch (Toggles 1,2,3,4) clock). DS1 Toggles) - Fast Ethernet: 1,2,3,4 OFF -- shown in - ATM/OC3/STM1:155 Mbps: 2,3,4 OFF, 1 ON Figure 1.3and - SMPTE 143 Mbps: 3,4 OFF, 1,2 ON 1.4 - E3: 34.368 Mbps1,2,4 OFF, 3 ON - T3: 44.736 Mbps: 2,4 OFF, 1,3 ON - OC1/STM0: 51.840 Mbps: 1,4 OFF, 2,3 ON - Customized 1 : 4 OFF, 1,2,3 ON - Customi
Streszczenie treści zawartej na stronie nr. 17
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Indicators Air RX Flag LED Green LED indicates data received by the Airlink (7-segment receiver. Turns ON at the threshold level. display and LEDs) Air RX Sync LED Yellow LED. Turns ON if the rate of the received Data matches the Data Rate set on the Data Rate DIP switch. F/O Main, RX Flag Upper green LED indicates Data received by the LED Fiber Optic receiver. Turns ON at the threshold level. F/O Main,
Streszczenie treści zawartej na stronie nr. 18
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l C. TS800/155-F (Standard Model including Fusion option) Figure 1.4: TS800/155-F Standard Model Panel Schematic This special TS800/155-F model can be connected to the back-up radio system without a special MRV switch and card supporting Fusion. This TereScope can be connected to any switch (supporting 10/100 Mbps data rate) via a standard converter that should be connected to the optical
Streszczenie treści zawartej na stronie nr. 19
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l That’s what happens when the air channel TS TS Main is interrupted. IR = 100 Mbps F/O F/O Redundant Main RF Transceiver RF Transceiver RF = 2-10 Mbps F/O 10 Base-T STP F/O Redundant Switch MC 10/100 Base-T 10/100TX-100FX Media Converter Network Network 10 Base-T STP Figure 1.5a: TereScope800/155 F - & Fusion System Connection For a description of the
Streszczenie treści zawartej na stronie nr. 20
M R V C o m m unic a t io ns , I n c . – I n s t a lla t i o n M a nua l Fusion Maximizing Link Availability in All Weather Conditions. The TereScope Fusion was designed to combine the best features of two transport mediums, laser light and radio waves, to form a single, seamless, wireless communication link between network devices. By leveraging both technologies, we can provide the 99.999% availability that your network requires. Protocol: 10Base-T (IEEE 802.1 1 b) Frequency: 2.4