Streszczenie treści zawartej na stronie nr. 1
ADAM-5000 Series
RS-485 Based Data Acquisition
and Control System
User’s Manual
Streszczenie treści zawartej na stronie nr. 2
Copyright Notice This document is copyrighted, 2001, by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd., reserves the right to make improvements to the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. However, Advantech
Streszczenie treści zawartej na stronie nr. 3
A Message to the Customer….. Advantech Customer Services Each and every Advantech product is built to the most exacting specifications to ensure reliable performance in the unusual and demanding conditions typical of industrial environments. Whether your new Advantech equipment is destined for the laboratory or the factory floor, you can be assured that your product will provide the reliability and ease of operation for which the name Advantech has come to be known. Your satisfac
Streszczenie treści zawartej na stronie nr. 4
Product Warranty Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for one year from the date of purchase. This warranty does not apply to any products which have been repaired or altered by other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation. Advantech assumes no liability as a consequence of such events under the terms of
Streszczenie treści zawartej na stronie nr. 5
4. Carefully pack the defective product, a completely filled-out Repair and Replacement Order Card and a photocopy of dated proof of purchase (such as your sales receipt) in a shippable container. A product returned without dated proof of purchase is not eligible for warranty service. 5. Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer.
Streszczenie treści zawartej na stronie nr. 6
Contents Chapter 1 Introduction ……………………………………… 1-1 1.1 Overview........................................................................1-2 1.2 System Configuration....................................................1-3 1.3 A Few Steps to a Successful System............................ 1-4 Chapter 2 Installation Guideline….…………………………2-1 2.1 General ......................................................................... 2-2 2.2 Module Installation .............
Streszczenie treści zawartej na stronie nr. 7
5.1.5 Terminal Emulation ..................................................... 5-7 5.1.6 Data Scope ................................................................... 5-8 5.1.7 Saving a Module’s Configuration to File .................. 5-10 5.1.8 Load Module’s Configuration File ............................ 5-12 5.1.9 Module Configuration ................................................ 5-14 5.1.10 Module Calibration .................................................... 5-15
Streszczenie treści zawartej na stronie nr. 8
Appendix A Quick Start Example….….………………………. A-1 A.1 System Requirements to Setup an ADAM-5000 System…. A-2 A.2 Basic Configuration Hook-up ..................................... A-5 A.3 Baud Rate and Checksum ........................................... A-8 A.4 A Distributed ADAM-5000 Network System Hook-up .... A-11 Appendix B Data Format and I/O Ranges……………………. B-1 B.1 Analog Input Formats ................................................... B-2 B.2 Analog Input Ran
Streszczenie treści zawartej na stronie nr. 9
E.5 Grounding reference (Ground bar for the factory, environment should have a standard resistance below W)…………….E-5 E.6 Some Suggestions on Wiring Layout ..........................E-6 Appendix F Grounding Reference………………………….…. F-1 F.1 Grounding ................................................................. F-3 F.2 Shielding ................................................................... F-9 F.3 Noise Reduction Techniques.................................... F-14
Streszczenie treści zawartej na stronie nr. 10
Figures Figure 1-1 ADAM-5000 Configurations……………….…………..1-3 Figure 2-1 ADAM-5000 Diagnostic indicators……….…………..2-3 Figure 2-2 ADAM-5000 Network address DIP switch.………….2-4 Figure 2-3 Module alignment and installation………………..…..2-6 Figure 2-4 ADAM-5000 Panel mounting.………………………..2-7 Figure 2-5 ADAM-5000 Rail mounting.…………………..……..2-8 Figure 2-6 ADAM-5000E Rail mounting..………………………..2-9 Figure 2-7 ADAM-5000 Wiring and connections..……………….2-10 Figure 2-8 Bu
Streszczenie treści zawartej na stronie nr. 11
Figure 5-10 Execute Span Calibration……………………...…..5-17 Figure 5-11 CJC Calibration…………………………….…..…..5-17 Figure 5-12 Execute CJC Calibration……………….………..…..5-18 Figure 5-13 RTD Module Calibration………………….…..…..5-18 Figure 5-14 Analog Output Calibration……………………..…..5-18 Figure 6-1 Baud rate codes………………………….………..…..6-6 Figure 6-2 Analog module error codes……….……………..…..6-18 Figure 6-3 Data format for 8-bit parameters……..…………..…..6-38 Figure 6-2 Data format of 8-bit
Streszczenie treści zawartej na stronie nr. 12
1 Introduction
Streszczenie treści zawartej na stronie nr. 13
Introduction 1.1 Overview The ADAM-5000 series is a complete product line that provides a wide variety of features in a data acquisition and control application. It includes 4 I/O-slots ADAM-5000/485 and 8 I/O-slots ADAM-5000E. They are remotely controlled by the host computer through a set of commands and transmitted in a RS-485 network. The system kernel is small, but offers many good features to the users. The modulardesign also provides more flexibility in the system configurat
Streszczenie treści zawartej na stronie nr. 14
Chapter 1 1.2 System Configuration The following diagram shows the system configurations possible with the ADAM-5000. Note: To avoid system over heating, only four ADAM-5024 are allowed to be installed on ADAM-5000E. ADAM-5000 1-3
Streszczenie treści zawartej na stronie nr. 15
Introduction 1.3 A Few Steps to a Successful System Step 1:Review the installation Guideline You should always make safety your first priority in any system application. Chapter 2 provides several guidelines that will help provide a safer, more reliable system. Step 2: Understand the System Kernel The system module is the heart of ADAM-5000 system. Make sure you take time to understand the various features and setup require- ments. Step 3: Understand the I/O System Configu
Streszczenie treści zawartej na stronie nr. 16
2 Installation Guideline
Streszczenie treści zawartej na stronie nr. 17
Installation Guideline 2.1 General Environmental Specifications The following table lists the environmental specifications that general ly apply to the ADAM-5000 system (System kernel and I/O modules). Specification Rating Storage temperature -13 to 185°F (-25 to 85°C) Ambient operating 14 to 158°F (-10 to 70°C) temperature Ambient humidity* 5 to 95%, non-condensing Atmosphere No corrosive gases * Equipment will operate below 30% humidity. However,
Streszczenie treści zawartej na stronie nr. 18
Chapter 2 A complete description of the diagnostic indicators and how to use them for troubleshooting is explained in Chapter 7. Figure 2-1 ADAM-5000 Diagnostic indicators Setting the Network Address Switch Set DIP switch 8 to OFF to install Avvantech Protocol , Set the network address using the 8-pin DIP switch. Valid settings range from 0 to 127 (00h to 7Fh) where ON in any of the 8 DIP switch po
Streszczenie treści zawartej na stronie nr. 19
Installation Guideline Figure 2-2 ADAM-5000 Network address DIP switch Dimensions and Weights(ADAM-5000) The following diagrams show the dimensions of the system unit and an I/O unit of the ADAM-5000. All dimensions are in millimeters. 2-4 ADAM-5000
Streszczenie treści zawartej na stronie nr. 20
Chapter 2 Dimensions and Weights(ADAM-5000E) The following diagrams show the dimensions of the system unit and the I/O unit of the ADAM-5000E. All dimensions are in millimeters. ADAM-5000 2-5