Streszczenie treści zawartej na stronie nr. 1
Serial ATA II
1430SA, 1420SA, 1220SA
HostRAID Controllers
Installation and User’s Guide
Streszczenie treści zawartej na stronie nr. 2
● 2 Copyright ©2006 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of Adaptec, Inc., 691 South Milpitas Blvd., Milpitas, CA 95035. Trademarks Adaptec, Adaptec Storage Manager, SCSISelect, SATASelect, SerialSelect and the Adaptec logo are trademarks of Adaptec, Inc., which may be registered i
Streszczenie treści zawartej na stronie nr. 3
● 3 Adaptec Customer Support If you have questions about installing or using your Adaptec product, check this document first—you will find answers to most of your questions. If you need further assistance, use the support options listed below. To expedite your service, have your computer in front of you. Technical Support Identification (TSID) Number ● Before contacting Technical Support, you need your unique 12-digit TSID number. The TSID number identifies your product and support status. ●
Streszczenie treści zawartej na stronie nr. 4
● 4 Limited 3-Year Hardware Warranty 1. Adaptec, Inc. (“Adaptec”) warrants to the purchaser of this product that it will be free from defects in material and workmanship for a period of three (3) years from the date of purchase. If the product should become defective within the warranty period, Adaptec, at its option, will repair or replace the product, or refund the purchaser’s purchase price for the product, provided it is delivered at the purchaser’s expense to an authorized Adaptec servic
Streszczenie treści zawartej na stronie nr. 5
● 5 Regulatory Compliance Statements Federal Communications Commission Radio Frequency Interference Statement WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interferen
Streszczenie treści zawartej na stronie nr. 6
Contents About This Guide What You Need to Know Before You Begin ................................................... 11 Terminology Used in this Guide...................................................................... 11 How to Find More Information....................................................................... 11 About Your HostRAID Controller HostRAID Controller Features ........................................................................ 13 Array Level Features ................
Streszczenie treści zawartej na stronie nr. 7
Contents ● 7 Installing the HostRAID Controller and Disk Drives Before You Begin............................................................................................... 23 Installing the HostRAID Controller................................................................. 23 Connecting Disk Drives to SATA HostRAID Controllers.............................. 24 Checking Your Controller and Devices ........................................................... 24 Determining the Boot Controller.
Streszczenie treści zawartej na stronie nr. 8
Contents ● 8 Understanding Adaptec Storage Manager Features.............................................................................................................. 40 Overview............................................................................................................ 40 Physical Devices View................................................................................. 41 Logical Devices View ................................................................................
Streszczenie treści zawartej na stronie nr. 9
Contents ● 9 Using the AFU for DOS Introduction ...................................................................................................... 61 System Requirements ................................................................................. 61 Compatibility .............................................................................................. 61 Running the AFU from the GUI ...................................................................... 62 Running the AFU from the C
Streszczenie treści zawartej na stronie nr. 10
About This Guide 1 In this chapter... What You Need to Know Before You Begin.......................................................................... 11 Terminology Used in this Guide............................................................................................ 11 How to Find More Information ............................................................................................ 11 ® This Installation and User’s Guide explains how to install your Adaptec Serial ATA controller
Streszczenie treści zawartej na stronie nr. 11
Chapter 1: About This Guide ● 11 What You Need to Know Before You Begin You should be familiar with computer hardware, data storage, Redundant Array of Independent Disks (RAID) technology, and the input/output (I/O) technology—SATA—used by your HostRAID controller. You should also be familiar with Direct Attached Storage (DAS) and Storage Area Network (SAN) concepts and technology. Terminology Used in this Guide Because you can use your HostRAID controller to manage data storage in a variety
Streszczenie treści zawartej na stronie nr. 12
About Your HostRAID Controller 2 In this chapter... HostRAID Controller Features.............................................................................................. 13 Upgrading the HostRAID Controller Firmware................................................................... 13 About the Adaptec 1430SA Controller.................................................................................. 14 About the Adaptec 1420SA Controller.....................................................
Streszczenie treści zawartej na stronie nr. 13
Chapter 2: About Your HostRAID Controller ● 13 HostRAID Controller Features ● Flash ROM for updates to controller firmware Adaptec Flash Utility (AFU), BIOS, and the Array Configuration Utility (ACU). ● Event logging and broadcasting, including messaging for alphanumeric pagers. ● Support for Adaptec Metadata Format (AMF) allowing the migration of simple volumes and arrays to Adaptec RAID controller cards. ● Multiple options for creating and managing RAID arrays—A full software application (A
Streszczenie treści zawartej na stronie nr. 14
Chapter 2: About Your HostRAID Controller ● 14 About the Adaptec 1430SA Controller The Adaptec 1430SA is a low-profile 4-port PCIe SATA II HostRAID controller with these features: Power LED J1 Connector (I2C) Aggregate LED Aggregate LED Port Activity LED Activity LED 3 (top port) 2 (bottom port) SATA ports 1 (top port) 0 (bottom port) Activity LED PCIe connector Mounting bracket Form factor Low-profile PCI compatibility PCIe x4 Ports 4 stacked Connectors 4 internal RAID levels 0, 1, 10 Simple
Streszczenie treści zawartej na stronie nr. 15
Chapter 2: About Your HostRAID Controller ● 15 About the Adaptec 1420SA Controller The Adaptec 1420SA is a low-profile PCI-X to 4 port SATA II HostRAID controller with these features: J1 Connector (I2C) J2 Connector (Activity LED) SATA ports 0 2 1 3 PCI-X connector Mounting bracket Form factor Low-profile PCI compatibility PCI-X x1 Ports 4 Connectors 4 internal RAID levels 0, 1, 10 Simple volume Yes Disk drives SATA I (1.5Gbps), SATA II (3.0Gbps) Maximum number of disk drives 4 Hot spares Yes
Streszczenie treści zawartej na stronie nr. 16
Chapter 2: About Your HostRAID Controller ● 16 About the Adaptec 1220SA Controller The Adaptec 1220SA is a low-profile PCIe to 2 port SATA II HostRAID controller with these features: 0 SATA ports 1 PCIe connector Mounting bracket Form factor Low-profile PCI compatibility PCIe PCI bus width (max) 64-bit PCI bus speed (max) 133 MHz Ports 2 Connectors 2 internal RAID levels 0, 1 Simple Volume Yes Disk drives SATA I (1.5Gbps), SATA II (3.0Gbps) Maximum number of disk drives 2 Hot spares Yes Enclosu
Streszczenie treści zawartej na stronie nr. 17
Kit Contents and 3 System Requirements In this chapter... Kit Contents............................................................................................................................ 18 System Requirements .............................................................................................................18 This chapter lists the contents of your HostRAID controller kit and the system requirements that must be met for you to successfully install and use your controller.
Streszczenie treści zawartej na stronie nr. 18
Chapter 3: Kit Contents and System Requirements ● 18 Kit Contents ● Adaptec SATA HostRAID controller ● HostRAID Installation CD (bootable), including controller drivers, and this Guide ● Adaptec Storage Manager Installation CD (not bootable), including user guides for Adaptec Storage Manager and the Adaptec HRCONF (HostRAID Configuration) command line utility ● Readme Files ● Cables (type and quantity vary for cable information about your HostRAID controller, see About Your HostRAID Controll
Streszczenie treści zawartej na stronie nr. 19
Getting Started 4 In this chapter... Choosing a RAID Level.......................................................................................................... 20 Selecting Disk Drives.............................................................................................................. 20 Selecting Cables ...................................................................................................................... 20 Installation Options .....................................
Streszczenie treści zawartej na stronie nr. 20
Chapter 4: Getting Started ● 20 Choosing a RAID Level This section provides a brief overview of the RAID levels supported by your HostRAID controller, including the minimum and maximum number of disk drives required by each. RAID 0 (Non-redundant Array)—Stripes data across multiple disk drives. Improved performance but no redundancy (see page 49). RAID 1 Array—Created from two disk drives where one disk drive is a mirror of the other (the same data is stored on each disk drive). Redundancy, b