Streszczenie treści zawartej na stronie nr. 1
Threat Analysis Reporter
®
QUICK START
GUIDE
Model: TAR
HL-005-004, SL-004-004, MSA-004-004
Release: 1.2.00 / Updated: 09.19.08
Streszczenie treści zawartej na stronie nr. 2
8e 6 Threa T a ysisnal r T epor er Quick s TarT Guide © 2008 8e6 Technologies. All rights reserved. This document may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any elec- tronic medium or machine readable form without prior written consent from 8e6 Technologies. Every effort has been made to ensure the accuracy of this document. However, 8e6 Technologies makes no war- ranties with respect to this documentation and disclaims any implied warranties of
Streszczenie treści zawartej na stronie nr. 3
Contents t threa a ysisnal r eporter i ntroduCtion ....................................................1 About this Document ....................................................................................................................2 Conventions Used in this Document ...........................................................................................2 s C vier e i tionnforma ..................................................................................3 p yreliminar s etup p
Streszczenie treści zawartej na stronie nr. 4
iv 8e 6 Threa Ta ysisnal r epor Ter Q uick s Tar T G uide
Streszczenie treści zawartej na stronie nr. 5
t threa a ysisnal r eporter i C ntrodu tion Thank you for choosing to evaluate the 8e6 Technologies Threat Analysis Reporter. This product addresses user-generated Web threats such as excessive use of bandwidth and inappropriate Internet usage, and provides network administrators tools to monitor such threats so management can enforce corporate Internet usage policies. Working in conjunction with 8e6’s R3000 Enterprise Filter, the Threat Analysis Reporter translates end user Internet activit
Streszczenie treści zawartej na stronie nr. 6
About this Document This document is divided into the following sections: • Introduction - This section is comprised of an overview of the Threat Analysis Re- porter product and how to use this document • Service Information - This section provides 8e6 Technologies contact information • Preliminary Setup Procedures - This section includes instructions on how to physi- cally set up the Threat Analysis Reporter unit in your network environment • Install the Server - This section explains how to co
Streszczenie treści zawartej na stronie nr. 7
s viC er e i tionnforma The user should not attempt any maintenance or service on the unit beyond the proce- dures outlined in this document. Any initial hardware setup problem that cannot be resolved at your internal organiza- tion should be referred to an 8e6 Technologies solutions engineer or technical support representative. 8e6 Corporate Headquarters (USA) Local : 714.282.6111 Domestic US : 1.888.786.7999 International : +1.714.282.6111 8e6 Taiwan Taipei Local : 2397-0300 Domestic
Streszczenie treści zawartej na stronie nr. 8
p yreliminar s etup p C ro edures Unpack the Unit from the Carton Inspect the packaging container for evidence of mishandling during transit. If the packag- ing container is damaged, photograph it for reference. Carefully unpack the unit from the carton and verify that all accessories are included. Save all packing materials in the event that the unit needs to be returned to 8e6 Tech- nologies. The carton should contain the following items: • 1 Threat Analysis Reporter unit • 1 AC Power Cord,
Streszczenie treści zawartej na stronie nr. 9
Select a Site for the Server The server operates reliably within normal office environmental limits. Select a site that meets the following criteria: • Clean and relatively free of excess dust. • Well-ventilated and away from sources of heat, with the ventilating openings on the server kept free of obstructions. • Away from sources of vibration or physical shock. • Isolated from strong electromagnetic fields and noise caused by electrical devices such as elevators, copy machines, air conditio
Streszczenie treści zawartej na stronie nr. 10
Rack Mount the Server Rack Setup Precautions Warning: Before rack mounting the server, the physical environment should be set up to safely ac- commodate the server. Be sure that: • The weight of all units in the rack is evenly distributed. Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. • The rack will not tip over when the server is mounted, even when the unit is fully extended from the rack. • For a single rac
Streszczenie treści zawartej na stronie nr. 11
Rack Mount Instructions for HL Servers Rack Setup Suggestions • Determine the placement of each component in the rack before you install the rails. • Install the heaviest server components on the bottom of the rack first, and then work up. Identify the Sections of the Rack Rails You should have received two rack rail assemblies with the 8e6 server unit. Each of these assemblies consists of two sections: An inner fixed chassis rail that secures to the unit (A), and an outer fixed rack rail th
Streszczenie treści zawartej na stronie nr. 12
Locking Tabs: Both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully ex- tended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing. 8 8e 6 Threa Ta ysisnal r epor Ter Q uick s Tar T G uide
Streszczenie treści zawartej na stronie nr. 13
Install the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server chassis into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). When the server has been pushed completely into the rack, you should hear the locking tabs “clic
Streszczenie treści zawartej na stronie nr. 14
Install the Server into a Telco Rack If you are installing the 8e6 server unit into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will ex- tend out the front of the rack. A larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chassis, then the two rear brackets positioned wi
Streszczenie treści zawartej na stronie nr. 15
Rack Mount Instructions for SL Servers Rack Setup Suggestions • Determine the placement of each component in the rack before you install the rails. • Install the heaviest server components on the bottom of the rack first, and then work up. Install the Inner Slides 1. Locate the right inner slide, (the slide that will be used on the right side of chassis when facing the front panel of the chassis). 2. Align the four (4) square holes on the right inner slide against the hooks on the right side
Streszczenie treści zawartej na stronie nr. 16
Install the Slide Assemblies to the Rack 1. After you have installed the short and long brackets to the outer slides, you are ready to install the whole slide assemblies (outer slides with short and long brackets at- tached) to the rack. (See the previous page.) 2. Use M5 screws and washers to secure the slide assemblies into the rack as shown below: 8e 6 Threa Ta ysisnal r epor Ter Q uick s Tar T G uide
Streszczenie treści zawartej na stronie nr. 17
Install the Chassis into the Rack 1. Push the inner slides, which are attached to the chassis, into the grooves of the outer slide assemblies that are installed in the rack as shown below: 2. Push the chassis all the way to the back of the outer slide assemblies as shown be- low: 8e 6 Threa Ta ysisnal r epor Ter Q uick s Tar TG uide
Streszczenie treści zawartej na stronie nr. 18
Rack Mount Instructions for MSA Servers Optional: Install the Chassis Rails NOTE: If your chassis does not come with chassis rails, please follow the procedure listed on the last page of this sub-section to install the unit directly into the rack. CAUTION: Please make sure that the chassis covers and chassis rails are installed on the chassis before you install the chassis into the rack. To avoid personal injury and property damage, please carefully follow all the safety steps listed below:
Streszczenie treści zawartej na stronie nr. 19
3. Locate the three holes on each side of the chassis and locate the three correspond- ing holes on each of the inner rail. 4. Attach an inner rail to each side of the chassis and secure the inner rail to the chas- sis by inserting three Type G screws through the holes on each side of the chassis and the inner rail. (See the diagram below for a description of the Type G screw.) 5. Repeat the above steps to install the other rail on the chassis. 8e 6 Threa Ta ysisnal r epor Ter Q uick s Tar
Streszczenie treści zawartej na stronie nr. 20
Optional: Install the Traditional UP Racks After you have installed the inner rails on the chassis, you are ready to install the outer rails of rail assemblies to the rack. NOTE: The rails are designed to fit in the racks with the depth of 28” to 33”. • Determine the placement of each component in the rack before you install the rails. • Install the heaviest server components on the bottom of the rack first, and then work up. 1. In the package, locate a pair of front (short) and rear (long) b