Streszczenie treści zawartej na stronie nr. 1
USA 1-800-944-9044 Canada 1-800-265-8352
www.frigidaire.com www.frigidaire.ca
LI30KC / 316902495
May/13
Streszczenie treści zawartej na stronie nr. 2
PRODUCT RECORD AND REGISTRATION Thank you for choosing Frigidaire. CONTENTS Important Safety Instructions ............................... 3 This Use & Care Guide is part of our commitment to List of materials ................................................... 5 customer satisfaction and product quality throughout the Electrical requirements ......................................... 5 service life of your new appliance.We view your purchase Location requirements ...............................
Streszczenie treści zawartej na stronie nr. 3
IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using this appliance. Save these instructions for future references WARNING Approved for residential appliances TO REDUCE THE RISK OF FIRE, ELECTRIC For residential use only SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Do not attempt to install or operate your appliance until A.Use this unit only in the manner intended by the you have read the safety precautions in this manual. manufacturer. If you have questions, contact t
Streszczenie treści zawartej na stronie nr. 4
IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING To Reduce The Risk Of Fire Or Electric Shock, Do TO REDUCE THE RISK OF INJURY TO PERSONS, Not Use This Hood With Any External Solid State IN THE EVENT OF A RANGE TOP GREASE FIRE, Speed Control Device. OBSERVE THE FOLLOWING: a)SMOTHER FLAMES wi th a close - fit ting l id, cookie sheet, or other metal tray, then turn off the gas WARNING burner or the electric element. BE CAREFUL TO PREVENT BURNS. If the flames do TO REDUCE THE RISK OF A RA
Streszczenie treści zawartej na stronie nr. 5
LIST OF MATERIALS LIST OF MATERIALS ELECTRICAL REQUIREMENTS Parts included in your hood Observe all governing codes and ordinances. • 4 - 0 . 4 5 x 1 . 3 c m m o u n t i n g s c r e w s Ensure that the electrical installation is adequate and in • 3¼” x 10” (8.3 x 25.4 cm) r ectangular metal v ent conformance with National Electrical Code, ANSI/NFPA system. 70 (latest edition), or CSA Standards C22.1-94, Canadian NOTE: An optional 7” round duct kit is available. You can Ele
Streszczenie treści zawartej na stronie nr. 6
LOCATION REQUIREMENTS Cabinet Dimensions IMPORTANT Observe all governing codes and ordinances. • It is the installer’s responsibility to comply with instal lation clear ances specified on the model/serial rating plate. The model/serial rating plate is located B inside the range hood on the left side (See page 2 for location). Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents. • Cabinet opening dimension
Streszczenie treści zawartej na stronie nr. 7
VENTING REQUIREMENTS Roof Venting Wall Venting • Vent system must terminate to the outdoors. B • Do not terminate the vent system into an attic or other enclosed area. A • Do not use a 4” (10.2 cm) laundry-type wall cap. A • Use a 3¼” x 10” (8.3 x 25.4 cm) r ectangular metal B vent. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended. • The length of vent system and number of elbows should be k ept to a minimum to pr o vide efficient C C performance. F or
Streszczenie treści zawartej na stronie nr. 8
VENTING REQUIREMENTS ¼” x 10” (8.3 cm x 25.4 cm) Vent System PREPARE THE LOCATION Vent Piece NOTE 3¼” x 10” (8.3 cm x 25.4 cm) 5.0 ft 90° elbow (1.5 m) Before making cutouts, make sure there is proper clearance within the ceiling or wall. 3¼” x 10” (8.3 cm x 25.4 cm) 12.0 ft flat elbow (3.7 m) 1.Disconnect power. . S elect a flat surf ace f or assembl ing the r ange hood. 3¼” x 10” (8.3 cm x 25.4 cm) 0.0 ft Place covering over that surface. wall cap (0.0 m) . Lift the range
Streszczenie treści zawartej na stronie nr. 9
PREPARE THE LOCATION To wire through top: Style 2 - Cut Openings for 3¼” x 10” (8.3 cm x . Mark a line distance (A) from the right of the .4 cm) Rectangular Vent System centerline on the underside of the cabinet. Mark the 7 point on this line that is ⁄8” (2.2 cm) from back wall. Roof Venting Drill a 1¼” (3.2 cm) diameter hole (B) through the cab T o mak e a 4” x 10½” (10.16 cm x 26. 7 cm) r ectangular net at this point. cutout on the underside of cabinet top and bottom: 1.Mark
Streszczenie treści zawartej na stronie nr. 10
PREPARE THE LOCATION Style 3 - Cut Openings for 3¼” x 10” (8.3 x 25.4 Install Vent System cm) Rectangular Vent Transition to Round Vent 1.Install vent through the vent opening in upper cabinet or wall. Complete venting system according to the Roof Venting selected venting method. See “Venting Requirements” To make a circular vent opening on the underside of the section. cabinet top: . Use caulking to seal exterior w al l or r oof opening 1.Mark a centerline on the underside of the top o
Streszczenie treści zawartej na stronie nr. 11
INSTALLING THE HOOD Use ¹⁄8” (3 mm) drill bit and drill 4 pilot holes as shown. Power Supply Cable Installation NOTE: Make the drill holes on the thin area of the slot. 1.For direct wire installations, run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances. A. Drill pilot hole There must be enough wiring from the fused disconnect A (or cir cui t br eak er) bo x to mak e the connection in the . I nstal l the 4 - .45
Streszczenie treści zawartej na stronie nr. 12
INSTALLING THE HOOD MAKE ELECTRICAL CONNECTION INSTALL RANGE HOOD (Recirculating version) WARNING 1.Lift the range hood up under cabinet and determine Electrical Shock Hazard final location b y centering beneath cabinet. Mark on Disconnect power before servicing. the underside of cabinet the location of the 4 keyhole Replace all parts and panels before operating. mounting slots on the range hood (See slots Failure to do so can result in death or electrical shock. dimensions on pag
Streszczenie treści zawartej na stronie nr. 13
RANGE HOOD USE . Remove the power supply knockout from the top RANGE HOOD USE or rear of the vent hood (depending on the incoming The range hood is designed to remove smoke, cooking location of your home power supply cable) and vapors and odors from the cooktop area. For best results, install a UL listed or CSA approved ½” strain relief. start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all A smoke and odors from the kit
Streszczenie treści zawartej na stronie nr. 14
RANGE HOOD CARE A Cleaning 4. R eplace scr ew in the fi l ter retainer. WARNING . T o clean gr ease fi l ter , soak To Reduce The Risk Of Fire Or Electrical shock the fi l ters in hot w ater using disconnect from power supply before cleaning. a mild detergent. Rinse well and shake to dry. Or place in upper rack of dishwasher A. Filter screw IMPORTANT to clean. Clean the hood and grease filters frequently NOTE: Do not use ammo- according to the following instructions. Repla
Streszczenie treści zawartej na stronie nr. 15
TROUBLESHOOTING Problem Possible Causes Solutions After installation, 1. The power line and the cable locking 1. Check the power connection with the unit is the unit doesn’t connector is not connecting properly. connected properly. work. 2. The wires from the switches are disconnected 2. Make sure the wires on the switches are or loose. connected properly. Light works, 1. The motor is defective, possible seized. 1. Change the motor. but motor is not 2. The thermally protected system detects if
Streszczenie treści zawartej na stronie nr. 16
Warranty Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will repair or replace any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions. In addition, the glass cooktop or radiant surface limited warranty. During the 2nd through 5th years from your original date of purchase, Electrolux will provide
Streszczenie treści zawartej na stronie nr. 17
printed in Mexico