Streszczenie treści zawartej na stronie nr. 1
Undercounter
FL-2291
Ovens
Rev. 3 (5/08) Page 1 of 10
5925 Heisley Road • Mentor, OH 44060-1833
INSTALLATION, OPERATION and MAINTENANCE
MANUAL for Cres Cor
TM
AQUATEMP HUMIDITY
UNDERCOUNTER OVENS
2000 WATTS
CO151XWUA5B
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Streszczenie treści zawartej na stronie nr. 2
Undercounter FL-2291 Ovens Rev. 3 (5/08) Page 2 of 10 5925 Heisley Road • Mentor, OH 44060-1833 TABLE OF CONTENTS SUBJECT PAGE INSTALLATION INSTRUCTIONS…........................…...…………….....…………...............3 OPERATING INSTRUCTIONS…………………………..……………...……..…….…..........4 Illustration, Figure 1………………………………..…………….....……………….......4 MAINTENANCE INSTRUCTIONS How to Clean the Unit………………………………....………….....………………......5 Trouble Shooting Guide……………………………...…………....………………….6, 7 Repl
Streszczenie treści zawartej na stronie nr. 3
Undercounter FL-2291 Ovens Rev. 3 (5/08) Page 3 of 10 5925 Heisley Road • Mentor, OH 44060-1833 INSTALLATION INSTRUCTIONS VENTING YOUR OVEN: 1. The purpose of ventilating hoods is to direct and 3. Most jurisdictions consider our low-temperature capture smoke, grease-laden vapors, heat, odors, ovens (maximum temperature is 350°F/177°C) as or fumes. low-heat appliances not requiring vent hoods. 2. Low temperature equipment (maximum 4. Installation must conform with local codes. The temperatu
Streszczenie treści zawartej na stronie nr. 4
95 90 20 0 80 Undercounter FL-2291 Ovens Rev. 3 (5/08) Page 4 of 10 5925 Heisley Road • Mentor, OH 44060-1833 OPERATING INSTRUCTIONS 1 5 7 2 4 6 3 TM 5 Roast-N-Hold + 160 250 230 270 4 6 130 190 210 MEDIUM 290 FLASHING - TIMIMG 7 ( I ) ON 190 3 310 100 220 160 LOW 8 140 180 PROOF 170 330 R 190 120 HIGH 200 2 LOW 100 HOURS MINUTES 70 250 F 9 WATER 210 150 350 F 80 60 220 20 DRY MOIST F 1 10 C START OFF ( 0 ) STOP TIME SELECT POWER HOLD COOK / RETHERM HUMIDITY TIMER 8 9 Figure 1: Control Panel PA
Streszczenie treści zawartej na stronie nr. 5
Undercounter FL-2291 Ovens Rev. 3 (5/08) Page 5 of 10 5925 Heisley Road • Mentor, OH 44060-1833 MAINTENANCE INSTRUCTIONS HOW TO CLEAN THE UNIT MAINTENANCE: WATER PAN MAINTENANCE: CABINET Drain, wipe and fi ll water pan daily. (Clear vinyl 1. Wipe the inside of cabinet after daily use. drain-hose is provided.) 2. Leave doors slightly open to fully dry interior. 1. Push hose onto drain nozzle under the base. 2. Turn knob to open the drain. HOW TO CLEAN THE UNIT: To fully Dry Out: Cleaning Hints:
Streszczenie treści zawartej na stronie nr. 6
Undercounter FL-2291 Ovens Rev. 3 (5/08) Page 6 of 10 5925 Heisley Road • Mentor, OH 44060-1833 MAINTENANCE INSTRUCTIONS: TROUBLE-SHOOTING GUIDE WARNING IF UNIT GETS TOO HOT OR WON’T SHUT OFF, DISCONNECT POWER AT BRANCH PANEL. DO NOT UNPLUG CORD! If hot unit is NOT working, fi rst check the following causes: 1. Cord is unplugged from wall outlet. 3. Switch is turned off. 2. Circuit breaker/fuse to wall outlet is blown. 4. Thermostat is turned off, or is set too low. PROBLEM POSSIBLE CAUSE SOLU
Streszczenie treści zawartej na stronie nr. 7
Undercounter FL-2291 Ovens Rev. 3 (5/08) Page 7 of 10 5925 Heisley Road • Mentor, OH 44060-1833 MAINTENANCE INSTRUCTIONS: TROUBLE-SHOOTING GUIDE, continued HOW TO ADJUST DOOR LATCH: 1. For vertical adjustment: (up and down movement) a. Loosen (2) screws located in magnetic strike b. Move strike up or down for alignment to magnet on latch. c. Tighten screws to secure. 2. For horizontal adjustment: (greater or lesser magnetic draw) a. Loosen (4) screws in door latch. b. Move latch forward or ba
Streszczenie treści zawartej na stronie nr. 8
95 90 20 0 80 Undercounter FL-2291 Ovens Rev. 3 (5/08) Page 8 of 10 5925 Heisley Road • Mentor, OH 44060-1833 REPLACEMENT PARTS: Include all information on nameplate when ordering parts. 1 5 7 2 4 6 3 TM 5 Roast-N-Hold + 160 250 230 270 4 6 130 190 210 MEDIUM 290 FLASHING - TIMIMG 7 ( I ) ON 190 3 310 100 220 160 LOW 8 140 180 PROOF 170 330 R 190 120 HIGH 200 2 LOW 100 HOURS MINUTES 70 250 F 9 WATER 210 150 350 F 80 60 220 20 DRY MOIST F 1 10 C START OFF ( 0 ) STOP TIME SELECT POWER HOLD COOK /
Streszczenie treści zawartej na stronie nr. 9
Undercounter FL-2291 Ovens Rev. 3 (5/08) Page 9 of 10 5925 Heisley Road • Mentor, OH 44060-1833 REPLACEMENT PARTS: Include all information on nameplate when ordering parts. 15 17 18 19 13 12 16 25 27 24 21 20 14 26 22 23 Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Streszczenie treści zawartej na stronie nr. 10
Undercounter FL-2291 Ovens Rev. 3 (5/08) Page 10 of 10 5925 Heisley Road • Mentor, OH 44060-1833 WIRING DIAGRAM Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com V HIGH TEMP V 16 17 FLOAT SWITCH 5-20P 18 BLUE HIGH LIMIT 120V; 20A WHITE HEATER WATER BLACK BLACK 11 ORANGE 120V/925W ORANGE W RED PN# 0811-271 RED G GREEN (DELTROL) (MAGNECRAFT) RELAY RELAY GREEN 13 1 21 20 19 21 22 BLUE 1 21 t° 7 5 8 9 10 5 4 6 7 HEATER 4 14 POWER 3 14 SENSOR WATER 12 1 2 SWITCH 3 WATER