Streszczenie treści zawartej na stronie nr. 1
Audio
Distribution
Network
ADN CU1
Quick guide
Streszczenie treści zawartej na stronie nr. 2
KA_ADN-CU1_546415_0911_SP13.book Seite 1 Donnerstag, 1. September 2011 11:00 11 Contents Contents Information on this quick guide ................................................................................ 2 The ADN CU1 central unit ............................................................................................ 2 Delivery includes .......................................................................................................... 3 Components required for operation ...
Streszczenie treści zawartej na stronie nr. 3
KA_ADN-CU1_546415_0911_SP13.book Seite 2 Donnerstag, 1. September 2011 11:00 11 Information on this quick guide Information on this quick guide Please make sure to read the “Safety information” supplement included separately with the product. This supplement contains important information on the safe operation of the product as well as the manufacturer’s declaration and warranty notes. A detailed instruction manual for the overall ADN conference system can be found • on the Internet at www.s
Streszczenie treści zawartej na stronie nr. 4
KA_ADN-CU1_546415_0911_SP13.book Seite 3 Donnerstag, 1. September 2011 11:00 11 Delivery includes Delivery includes 1 ADNCU1 central unit 1 mains cable (EU, UK or US version), length 1.8 m 1 quick guide 1 “Safety information” supplement 1 including, among other things, the “Conference Manager” software, the “ADN Cable Calculator” software and the instruction manual for the overall conference system as PDF Components required for operation Central unit/ Number Description Cat. No. Function Pow
Streszczenie treści zawartej na stronie nr. 5
KA_ADN-CU1_546415_0911_SP13.book Seite 4 Donnerstag, 1. September 2011 11:00 11 Product overview ADN CU1 central unit Product overview ADN CU1 central unit 1 23 45 ESC IN –– AUDIO –– OUT PORT II PORT I 100-240V~ 50/60Hz 240W 2x 52.8V 1.75A D 6 7 8 9 @ A B C E F 15 A Front view B Rear view 1 On/off switch 6 IN audio input 7 OUT audio output 2 Standard display key 8 PORT II socket (RJ 45) for connection 3 Display panel of conference units 4 Jog dial 9 PORT I socket (RJ 45) for connection
Streszczenie treści zawartej na stronie nr. 6
KA_ADN-CU1_546415_0911_SP13.book Seite 5 Donnerstag, 1. September 2011 11:00 11 Product overview ADN CU1 central unit Overview of the ADN CU1 display panel After switch-on, the central unit’s display shows progress bars (for the booting routine “Booting” and the self test “Selftest”) and then the standard display: I G H Direct Access 30 Units 22 O P N M L K J Text/icon Possible display/function G Conference mode Current conference mode: “Direct Access”, “Override”, “Push To Tal
Streszczenie treści zawartej na stronie nr. 7
PORT I KA_ADN-CU1_546415_0911_SP13.book Seite 6 Donnerstag, 1. September 2011 11:00 11 Structuring and controlling the conference system Structuring and controlling the conference system Structuring the conference system The ADN conference system is suitable for conferences with up to 400 conference units. For safe operation of the conference system, make sure that all conference units are supplied with a voltage of at least 35 V! The voltage supplied depends on the number of connected confe
Streszczenie treści zawartej na stronie nr. 8
PORT II 1 PORT II 2 KA_ADN-CU1_546415_0911_SP13.book Seite 7 Donnerstag, 1. September 2011 11:00 11 Structuring and controlling the conference system Large conference system with simple cabling For setting up a large conference system with the maximum number of conference units (i.e. up to 400), you require one ADN CU1 central unit for controlling the con- ference and additional ADN PS power supplies for powering the conference units. The conference units are interconnected in cable strings a
Streszczenie treści zawartej na stronie nr. 9
PORT II 1 PORT II 2 KA_ADN-CU1_546415_0911_SP13.book Seite 8 Donnerstag, 1. September 2011 11:00 11 Structuring and controlling the conference system Large conference system with redundant ring topology The redundant ring topology ensures that, should one conference unit or system cable fail or be manipulated, all other conference units of the cable ring will continue to function reliably. For setting up a large conference system with redundant ring topology, you require one ADN CU1 central u
Streszczenie treści zawartej na stronie nr. 10
KA_ADN-CU1_546415_0911_SP13.book Seite 9 Donnerstag, 1. September 2011 11:00 11 Preparing the ADN CU1 central unit for use The “Conference Manager” software can be run in two different ways: 1. As a program on the central unit’s built-in PC. You have to connect a screen, keyboard, and mouse to the central unit (see page 13). ADN CU1 2. As a program on a Windows PC. Conference Manager software You have to install the “Conference Manager” software on the PC and integrate the PC together with t
Streszczenie treści zawartej na stronie nr. 11
KA_ADN-CU1_546415_0911_SP13.book Seite 10 Donnerstag, 1. September 2011 11:00 11 Setting up the conference system Setting up the conference system CAUTION Product damage due to an unsuitable power supply! If you connect standard network devices with RJ 45 plugs (e.g. switches or network cards) to the connection sockets PORT I and PORT II, the network devices can be damaged due to an unsuitable power supply. Only connect ADN C1 and ADN D1 conference units to the connection sockets PORT I and
Streszczenie treści zawartej na stronie nr. 12
KA_ADN-CU1_546415_0911_SP13.book Seite 11 Donnerstag, 1. September 2011 11:00 11 Setting up the conference system Setting up a small conference system with only the central unit For a small conference system, you do not require ADN PS power supplies. Connecting conference units The following describes how to connect one cable string to the ADN CU1 central connected in a cable string to the unit. If necessary, repeat these steps for a second cable string. ADN CU1 central unit 8 9 Use a syste
Streszczenie treści zawartej na stronie nr. 13
KA_ADN-CU1_546415_0911_SP13.book Seite 12 Donnerstag, 1. September 2011 11:00 11 Setting up the conference system Connecting ADN PS power supplies to the ADN CU1 central unit For conference systems comprising more than 40 conference units or when the conference units are connected in a redundant ring topology, you require ADN PS power supplies. A max. of 15 ADN PS power supplies can be used in a conference system. 8 9 Use a system cable to connect the PORT II socket or PORT I socket of the
Streszczenie treści zawartej na stronie nr. 14
KA_ADN-CU1_546415_0911_SP13.book Seite 13 Donnerstag, 1. September 2011 11:00 11 Setting up the conference system A Connect the USB mass storage device to one of the two USB sockets . If necessary, connect the mains unit of the USB mass storage device. IN –– AUDIO –– OUT PORT II PORT I HDD 100-240V~ 2x 52.8V 1.75A 50/60Hz 240W A Preparing to use the “Conference Manager” software Running the software installed To use the “Conference Manager” software installed on the central unit, you
Streszczenie treści zawartej na stronie nr. 15
KA_ADN-CU1_546415_0911_SP13.book Seite 14 Donnerstag, 1. September 2011 11:00 11 Using the ADN CU1 central unit Using the ADN CU1 central unit Switching the conference system on/off To switch the conference system on: On the ADN CU1 central unit and the ADN PS power supplies, set the on/off ADN CU1 1 switch to position “I”. ESC The central unit switches on and its display panel lights up. The power supplies switch on and their status LEDs light up. To switch the conference system off: 1 1
Streszczenie treści zawartej na stronie nr. 16
KA_ADN-CU1_546415_0911_SP13.book Seite 15 Donnerstag, 1. September 2011 11:00 11 Configuring the conference system Configuring the conference system Overview of the operating menu “XLR Out” “Conference Menu” submenu submenu XLR Out Status Conference Mode XLR Out Vo lume Microphone Limit XLR Out Equalizer Request Limit Talk Time Status Talk Time Limit “XLR In” Premonition Time Limit submenu Reaction on Talktime Exceed Blink on Request Re-Init XLR In Status Clear Request List on Cancel XL
Streszczenie treści zawartej na stronie nr. 17
KA_ADN-CU1_546415_0911_SP13.book Seite 16 Donnerstag, 1. September 2011 11:00 11 Configuring the conference system Display Function of the menu item Option/display “Main Menu” “Conference Menu” Calls up the “Conference Menu” submenu – “Audio Menu” Calls up the “Audio Menu” submenu – “System Menu” Calls up the “System Menu” submenu – “*Languages” Adjusts the language “Deutsch”, “English”, “Espanol”... “Settings” Calls up the “Settings” submenu – “Conference Menu” “Conference Mode” Adjusts the
Streszczenie treści zawartej na stronie nr. 18
KA_ADN-CU1_546415_0911_SP13.book Seite 17 Donnerstag, 1. September 2011 11:00 11 Configuring the conference system Display Function of the menu item Option/display “Audio Menu” “XLR Out” Calls up the “XLR Out” submenu – “XLR In” Calls up the “XLR In” submenu – “Floor/Loudspeakers” Calls up the “Floor/Loudspeakers” submenu – “Audio Gain Reduction” The sum signal of all active conference units is output via “0.0 dB per Mic” ... the floor channel (“Floor/Loudspeakers”). The “Audio “ −3.0 dB per
Streszczenie treści zawartej na stronie nr. 19
KA_ADN-CU1_546415_0911_SP13.book Seite 18 Donnerstag, 1. September 2011 11:00 11 Configuring the conference system Display Function of the menu item Option/display “Floor/Loudspeakers” menu “Floor/Loudspeakers Volume” Adjusts the floor channel volume (“Floor/Loudspeakers”) Floor/Loudspeaker Volume 16 16 No “00” ... “32” “Floor/Loudspeakers Equalizer” Adjusts the tone color of the floor channel Floor/Loudspeaker Equalizer +02 dB –03 dB +05 dB No “ −12 dB” ... “+12 dB” “Feedback Suppression” me
Streszczenie treści zawartej na stronie nr. 20
KA_ADN-CU1_546415_0911_SP13.book Seite 19 Donnerstag, 1. September 2011 11:00 11 Configuring the conference system Display Function of the menu item Option/display “Start Self-Test” Performs a self-test on the conference system “Yes”/“No“ “Reset Break Indication” Resets the error counter (“Break Count”) in the “Bus “Yes”/“No” Statistic” menu item “Reset Error Indication” Resets the display for data bus errors (“Error Indication”) “Yes”/“No” in the “Bus Statistic” menu item “Versions” menu “Ha