200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 1
Owner’s Manual
®
APS PowerVerter
1111 W. 35th Street
Chicago, IL 60609 USA
Alternative Power Sources
Customer Support: (773) 869-1234
www.tripplite.com
(120V, 60 Hz)
Voltage- and Frequency-Controlled
Peak Power, High Efficiency
Español: pg. 16
Introduction: p. 2 - 3
Safety: p. 4
Configuration & Connection: p. 5-10
Features: p. 10 - 11
Maintenance & Service: p. 12
Warranty: p. 12
Troubleshooting: p. 13
Specifications: p
Streszczenie treści zawartej na stronie nr. 2
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 2 Introduction Congratulations! You’ve purchased the most advanced, feature-rich integrated inverter/battery charger on the market. Your APS provides your equipment with utility-supplied AC power when it is available, and during blackouts, overvoltages and brownouts, your APS automatically switches over to an external battery source to power connected equipment with voltage and frequency- controlled AC power. In addition to r
Streszczenie treści zawartej na stronie nr. 3
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 3 Advanced, 3-Stage Battery Charger Stage 2 Absorption Your APS recharges your battery faster than conventional chargers because its three-stage charger pro- Stage 3 file (Bulk, Absorption and Float) are Float optimized, regardless of the type of battery you use (Wet or Gel).* In addi- tion, the advanced charging system protects against over-charge and over-discharge to ensure a longer service life from your battery. *The
Streszczenie treści zawartej na stronie nr. 4
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 4 Safety This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite APS Systems. APS Location Warnings Install your APS indoors, away from excess moisture or heat, dust or direct sunlight. Your APS is NOT waterproof. Contact with water can cause the unit to short circuit and could cause personal injury due to electric shock. Never immer
Streszczenie treści zawartej na stronie nr. 5
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 5 Configuration CONFIGURATION DIP SWITCH SETTINGS DIP SWITCH GROUP A (All models) BATTERY TYPE / VOLTAGE POINT Using a small tool, set the 4 “Battery Type / Voltage Point” Configuration DIP Switches, Group A (located on the front panel of your APS; see Diagram 1, p. 32) to select battery type and set the voltage range outside of which your APS will switch to battery power. Select Battery Type (DIP Switch #1, Group A) CAUTIO
Streszczenie treści zawartej na stronie nr. 6
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 6 Load Sharing (DIP Switches #1, Group B & #2, Group B) Your APS features a high-output battery charger that can draw a significant amount of power from your line power source when charging at its maximum rate. If an APS is supplying its full AC power rating to its connected load at the same time as it is charging, it could trip its line source circuit breaker. Tripping this breaker will cut off AC power to your load and st
Streszczenie treści zawartej na stronie nr. 7
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 7 Limit Battery Charger (APS 1012 and APS 2012 only) (DIP Switch #4, Group B) To prevent overheating smaller batteries, the charger on these UPS systems is initially set to deliver only a fraction of its maximum power rating to connected batteries. If you are using either of these APS systems with a larger battery or battery system (over 100 amp-hours at 12 volts for the APS 1012, over 200 amp-hours at 12 volts for the APS
Streszczenie treści zawartej na stronie nr. 8
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 8 Mounting (Optional*) (See Diagram 2, p. 32). User must supply all fasteners and brackets and verify their suitability for use with the intended mounting surface. Turn your APS PowerVerter and connected equipment OFF before mounting. Install two 8 mm (1/4 in.) fasteners (A) into a rigid horizontal surface using the measurements in the diagram. Leave the heads of fasteners raised slightly above the surface in order to engag
Streszczenie treści zawartej na stronie nr. 9
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 9 vehicular battery connection. Choose the Basic Connection if you are running light hand tools or other small appliances for a brief period of time (see Diagram 7, p. 34). Choose the Advanced Connection if you are using your APS to power heavy loads for extended periods of time (see Diagram 8, p. 34). The Advanced Connection incorporates a battery isolator and separate battery system to provide battery power to your APS whil
Streszczenie treści zawartej na stronie nr. 10
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 10 Set Operating Mode Switch continued Switch to “CHARGE ONLY” when you are not using connected equipment. (WARNING! APS will not provide battery backup!) ADVANTAGES: A) Continues to charge battery when power is present, and B) Turns OFF the APS’s inverter, preventing battery drain during blackouts or brownouts. Switch to “OFF” to completely turn off the APS and connected equipment or to reset the APS after it has shut
Streszczenie treści zawartej na stronie nr. 11
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 11 8. “BATTERY HI/MED/LO” (All models) These three lights will turn ON in several sequences to show the approximate charge level and voltage of your connected battery bank and alert you to several fault conditions: BATTERY CHARGE INDICATION (Approximate) Indicator Capacity Green 91% - Full Green & yellow 81% - 90% Yellow 61% - 80% Yellow & red 41% - 60% Red 21% - 40% All three lights off 1% - 20% Flashing red 0% (Inverter shu
Streszczenie treści zawartej na stronie nr. 12
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 12 Maintenance & Service Maintenance Your APS model requires no maintenance but should be kept dry at all times. Periodically check all cable connections both at the unit and at the battery. Clean and tighten connections as necessary. Service If returning your APS to Tripp Lite, please pack the APS carefully, using the ORIGINAL PACKING MATERIAL that came with the unit. Enclose a letter describing the symptoms of the problem.
Streszczenie treści zawartej na stronie nr. 13
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 13 Troubleshooting Try these remedies for common APS problems before calling for help. Call Tripp Lite Customer Service at (773) 869-1234 before returning your APS for service. SYMPTOM PROBLEMS CORRECTIONS APS does not provide APS not properly connected to Connect APS to utility power. AC output (AC input present) utility power. Circuit breaker is tripped. Reset circuit breaker. APS shutdown due to excessive Turn APS “OFF”. W
Streszczenie treści zawartej na stronie nr. 14
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 14 Specifications (Corded Models) CORDED MODELS: APS 1012 APS 1024 Weight: 26.4 lbs. 26.4 lbs. INVERTER Continuous power (@ 20° C): 900 W 1000 W Surge power (5 seconds): 1800 W 2000 W Efficiency (Full Load): 90% 90% Minimum DC Fuse Rating: 225A 125A DC Input Current @ Nominal V DC Full Load 95 A 47 A No Load 2.2 A* 1.3 A* Nominal Input Volts: 12 VDC 24 VDC DC Input Voltage Range: 10-15 VDC 20-30 VDC Nominal Output Volts: 1
Streszczenie treści zawartej na stronie nr. 15
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 15 Specifications (Hardwired Models) HARDWIRED MODELS: APS 2012 APS2424 Weight: 38.0 lbs. 41.0 lbs. INVERTER Continuous power (@ 20° C): 2000 W 2400 W Surge power (5 seconds): 4000 W 4800 W Efficiency (Full Load): 90% 90% Minimum DC Fuse Rating: 500A 300A DC Input Current @ Nominal V DC Full Load 192 A 112 A No Load 2.5 A* 1.5 A* Nominal Input Volts: 12 VDC 24 VDC DC Input Voltage Range: 10-15 VDC 20-30 VDC Nominal Output
Streszczenie treści zawartej na stronie nr. 16
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 16 Manual de Operación ® APS PowerVerter 1111 W. 35th Street Fuentes Alternativas de Energía Chicago, IL 60609 USA Servicios a Clientes: (773) 869-1234 (120V, 60 Hz) www.tripplite.com Con Voltaje y Frecuencia Controlada Energía de Cresta - Alta Eficiencia Introducción: p. 17 - 18 Seguridad: p. 19 Configuración y Conexión: p. 20 - 25 Características: p. 25 - 27 Mantenimiento y Servicio: p. 27 Garantía: p. 28 Resolució
Streszczenie treści zawartej na stronie nr. 17
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 17 Introducción ¡Felicitaciones! Usted ha adquirido el inversor / cargador de batería integrado más avanzado y con más características en el mercado. Este modelo APS suministrará a sus equipos energía de CA mientras ésta esté presente. Durante un apagón, caída o subida de voltaje, esta unidad cambia automáticamente a la batería externa para suministrar energía de CA de voltaje y frecuencia controlada. Salida de Alta Efic
Streszczenie treści zawartej na stronie nr. 18
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 18 Cargador Avanzado Etapa 2 Absorción de 3 Etapas para Baterías Este sistema APS recargará sus baterías más Etapa 3 rápido que otros cargadores convencionales Alimentación debido a que su perfil de recarga de 3 etapas por Flotador (Alimentación en Masa, Absorción y Alimentación por Flotador) provee óptimo rendimiento independientemente del tipo de baterías que usted utilice (Húmeda o de Gel).* Además, el sistema avanzado d
Streszczenie treści zawartej na stronie nr. 19
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 19 Seguridad Este manual contiene advertencias e instrucciones importantes que deben seguirse durante la instalación, operación y almacenaje de todos los Sistemas APS de Tripp Lite. Precauciones Sobre la Ubicación del APS Instale este sistema bajo techo, lejos de calor o humedad excesivos, polvo o luz solar directa. Deje suficiente espacio alrededor del APS para permitir ventilación adecuada. No instale este sistema APS
Streszczenie treści zawartej na stronie nr. 20
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 20 Configuración Regulación de los Interruptores DIP de Configuración GRUPO A DE INTERRUPTORES DIP (Todos los modelos) TIPO DE BATERÍAS / PUNTOS DE VOLTAJE Usando una herramienta pequeña, ajuste los 4 Interruptores DIP de Configuración, Grupo A: “Battery Type / Voltage Point” (tipo de baterías / punto de voltaje) ubicados en el panel frontal del sistema APS (vea el Diagrama 1, página 32) para seleccionar el tipo de baterías