Streszczenie treści zawartej na stronie nr. 1
COMPACT 155 Mbit/s
ADD-DROP MULTIPLEXER
MULTIPLEXEUR ADD-DROP
à 155 Mbit/s COMPACT
ADR 155C
Installation and User Guide
Guide d'Installation et d'Utilisation
N56717020101
Issue : April 2000
Edition : Avril 2000
Streszczenie treści zawartej na stronie nr. 2
Streszczenie treści zawartej na stronie nr. 3
COMPACT 155 Mbit/s ADD-DROP MULTIPLEXER MULTIPLEXEUR ADD-DROP à 155 Mbit/s COMPACT ADR 155C Installation and User Guide Guide d'Installation et d'Utilisation N56717020101 Issue : April 2000 Edition : Avril 2000
Streszczenie treści zawartej na stronie nr. 4
LIST OF CHANGES REPERTOIRE DES MISES A JOUR (A new edition replaces any previous versions) (Une nouvelle édition annule et remplace la précédente) No/N° Date/Date Change description/Description de la Page/Page mise à jour 0101 April 2000/ Creation of original user guide/ All pages/ Avril 2000 Création du document à l'édition originale Toutes pages Remarque importante : La version logicielle actuelle n'offre pas la fonction RIP décrite dans ce guide. Important remark : The current software versio
Streszczenie treści zawartej na stronie nr. 5
COMPACT 155 Mbit/s ADD-DROP MULTIPLEXER ADR 155C Installation and User Guide Installation and User Guide - N56717020101 Reproduction and communication in any form prohibited without the written permission of ( Page A0-1
Streszczenie treści zawartej na stronie nr. 6
PORTS SECURITY LEVEL Port safety level for the 19" subrack access The connectors are identified on the front panels of the equipment (cards or motherboard). Connectors Function Security level 1 PWRA/PWRB Power supply SELV PWR Power supply SELV Motherboard SYNC G.703 2 Mbit/s synchronization Ports SELV E1 INPUT & E1 OUTPUT G.703 2 Mbit/s Ports SELV MNGT Other equipment connection SELV COMM VT100 local supervision SELV ETH Ethernet LAN remote supervision SELV LOOPS Loops and remote signaling SELV
Streszczenie treści zawartej na stronie nr. 7
CONTENTS CHANGE LIST 0-2 SECTION A : Installation and user guide ...................... A0-1 to AA-6 PORTS SECURITY LEVEL A0-2 CONTENTS A0-3 to A0-4 1. INSTALLATION AND COMMISSIONING ........................................................... A1-1 to A1-28 1.1 - General A1-1 1.2 - Subrack installation A1-3 1.3 - Connecting ports A1-4 1.3.1 - Connecting Power Supply A1-4 1.3.2 - Connecting on motherboard A1-7 1.3.3 - Connecting on the ADR IC1.x card A1-13 1.3.4 - Connecting on ADR LAN1 card A1-1
Streszczenie treści zawartej na stronie nr. 8
Figure 2-1 Synchronization from the 2 MHz external sync input (T3) A2-10 Figure 2-2 Synchronization from the 2 MHz port A2-10 Figure 2-3 Remote loopback function (registering alarms on central site) A2-11 Tables 2-1 to 2-6 Configuration parameters A2-2 to A2-7 Tables 2-7 to 2-8 Commands A2-8 to A2-9 Tables 2-9 to 2-10 Alarms and severity A2-13 to A2-14 3. SPARE PARTS....................................................................................................... A3-1 to A3-2 4. SPECIFICATI
Streszczenie treści zawartej na stronie nr. 9
1 - INSTALLATION AND COMMISSIONING 1. INSTALLATION AND COMMISSIONING 1.1 - General The ADR 155C is an optical STM-1 add-drop multiplexer used to build STM-1 point-to-point links, STM-1 rings, or mesh networks with conduct (SNC) or line (MSP) protection, so performing the conveyance of links at 2 Mbit/s, Ethernet, STM-1. The ADR 155C can be used as: STM-1 terminal multiplexer with maximum capacity of 63 VC12 and capability of 1+1 protection, STM-1 repeater, capability of regenerating 2 VC4,
Streszczenie treści zawartej na stronie nr. 10
2 2 1 - INSTALLATION AND COMMISSIONING P B A V D M C ADR 155C Subrack Left uprights of rack ADR 155C ADR 155C ETSI RACK 19" SUBRACK 66 ( 3 7 66 ( 3 7 2 2 Two M6x12 Two M6x12 1 1 HM screw HM screw Two M6 Two M6 cage nuts cage nuts 19" rack mounting ETSI rack mouting Figure 1-1- ADR155C Subrack Installation Installation and User Guide - N56717020101 Page A1-2 No reproduction or communication without the written consent of SAGEM SA 76,2 mm 2U 76,2 mm 2U 87 738 87 28 ( <1& <1& 87 738 87 28 <1& (
Streszczenie treści zawartej na stronie nr. 11
1 - INSTALLATION AND COMMISSIONING 1.2 - Subrack installation The ADR 155C subrack can be installed in 19" rack or ETSI frame (see Figure 1-1). It consists of: a motherboard located in the lower part (item M), four non-dedicated slots (items A to D), designed to accommodate the traffic cards, a slide located on the left of the subrack designed to accommodate the ventilation module (item V), a power supply (item P). All connections are performed on front panel, either on the subrack, or o
Streszczenie treści zawartej na stronie nr. 12
1 - INSTALLATION AND COMMISSIONING 1.3 - Connecting ports The connections to be performed on the equipment depend on the configuration chosen: On the power supply card: poser supply ports: "PWR" or "PWRA" and/or "PWRB", On the subrack motherboard strip: management ports : "COMM", "ETH" and/or "MNGT" Remote indication, remote control and station alarm port : "LOOPS" 2Mbit/s G.703 synchronization port : "SYNC" 21x2Mbit/s G.703 traffic ports: "E1 INPUT" and "E1 OUTPUT". Depending on the t
Streszczenie treści zawartej na stronie nr. 13
1 - INSTALLATION AND COMMISSIONING Description of power supply ports POWER - 48V 2A MAX "PWR" Jack type connector F4AL250V Fuse 4A Quick fuse low power shutdown 250V PWRA and PWRB 1 - 48 B1 5 2 - 48 B1 6 OB1 9 3 - Reserved 7 OB1 6 4 - 48 B2 8 OB2 1 5 - 48 B2 9 OB2 ADR-155C Figure 1-2 – Connecting power supply ports "PWRA"/"PWRB" power supply interface: Input voltage : One or two Safety Extra Low Voltage (SELV) ty
Streszczenie treści zawartej na stronie nr. 14
1 - INSTALLATION AND COMMISSIONING LOOPS 8 1 9 15 1 : Break B 2 : Make B 9 : Common B 3 : Common A 10 : Break A 4 : Gnd 11 : Make A 5 : R-MON 4 N 12 : R-MON 4 P (OB) "SYNC" 6 : R-MON 3 N 13 : R-MON 3 P (OB) 5 1 7 : R-MON 2 N 14 : R-MON 2 P (OB) 8 : R-MON 1 N 15 : R-MON 1 P (OB) 6 9 Schematic diagram 1 : GND of a dry loop 2 : TX1_TIP 6 : TX1_RING 3 : RX1_TIP 7 : RX2_TIP M 4 : RX2_RING 8 : RX1_RING CB 5 : RESERVED 9 : RESERVED "E1 OUTPUT"and "E1 INPUT" 15 1 30 16 Green "
Streszczenie treści zawartej na stronie nr. 15
1 - INSTALLATION AND COMMISSIONING 1.3.2 - Connecting on motherboard 1.3.2.1 - Remote indication, remote control and station alarm port ("LOOPS") "LOOPS" Interface: Ports 4 remote indication inputs for floating contacts (Local user inputs), biased to -48 V internally, active when closed and with electrical isolation (loop current = from 1 to 10 mA), 2 dry loop outputs (common, normally closed and normally open) (Local user outputs) for station alarm or remote control use (maximum current = 1
Streszczenie treści zawartej na stronie nr. 16
1 - INSTALLATION AND COMMISSIONING NOTE: Two LEDs are linked to the "ETH" port: • LED, "Activity", green colour : Trafic status indicator, • LED, "Link", yellow colour : Link status indicator. 1.3.2.2 - Management and Administration ports "COMM" Interface: Ports RS232, connecting VT100 standard console or emulation Bit rate 19200 bauds (8 data bits, no parity bit and 1 stop bit), Connector Female 9-way HE5 5 1 9 6 Pin N° Signal name Comments 1 DCD Connected to DSR 6 DSR Data Set Ready (to DCE)*
Streszczenie treści zawartej na stronie nr. 17
1 - INSTALLATION AND COMMISSIONING "MNGT" Interface: Port V.11 synchronous (differential) interconnection possible with other SAGEM equipment ADR155C, FOT 155C, through serial synchronous links used in codirectional mode at 64 kbit/s or master contra-directional mode (rate defined by the ADR 155C) Bit rate 64 kbit/s, Connector Female 9-way HE5. 5 1 9 6 Pin N° Signal name Polarity Comments 1 GND Ground (no connected) 6RXPB (+) Input for data received over the P interface and sampled on the rising
Streszczenie treści zawartej na stronie nr. 18
1 - INSTALLATION AND COMMISSIONING 1.3.2.3 - G.703 2 Mbit/s Synchronization port "SYNC" Interface Ports Two G.703 2MHz external synchronization inputs (T3) and one G.703 2MHz clock output (T4) compliant with ITU-T G.703 Recommendation (§ 10.3 for input port, § tab.10 for output port) Bit rate 2,048 Mbit/s ± 50 ppm, Impedance 120 Ω balanced, Connector Female 9-way HE5 (120 Ω). 5 1 6 9 Pin N° Signal name Comments 1 GND Ground 6 TX1 RING (T4-) Output T4-1 (cold point) 2 TX1 TIP (T4+) Output T4-1
Streszczenie treści zawartej na stronie nr. 19
1 - INSTALLATION AND COMMISSIONING Pin N° Ports Signal name C omments 16 GND ground 31 1 TX(RX) 1B Output (Input) 2 Mbit/s (hot point) 1 TX(RX) 1A Output (input) 2 Mbit/s (cold point) 17 2 TX (RX) 2B Output (Input) 2 Mbit/s (hot point) 32 TX(RX) 2A Out put (input) 2 Mbit/s (cold point) 2 3 TX (RX) 3B Out put (Input) 2 Mbit/s (hot point) 18 TX(RX3A Output (input) 2 Mbit/s (cold point) 33 4 TX(RX) 4B Output (Input) 2 Mbit/s (hot point) 3 TX(RX) 4A Out put (input)
Streszczenie treści zawartej na stronie nr. 20
1 - INSTALLATION AND COMMISSIONING STM1 transmission port STM1 reception port ADR IC1 STATUS EOW AUX TR REC " " " EOW and AUX LED STATUS 81 Green Red 9 15 ON OFF Card in service 1 : NC ON ON Card in alarm 2 : TA 9 : TB OFF OFF Hardware default (fuse) 3 : TOF PA 10 : TOF PB OFF ON Card out of service 4 : RA 11 : RB Flashing Autotest default 5 : ROF PA 12 : ROF PB 6 : R64 A 13 : R64 B 7 : T64 A 14 : T64 B 8 : GND 15 : NC Version 1 STM1 transmission port STM1 reception port A