Streszczenie treści zawartej na stronie nr. 1
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
Invitium Battery System
GETTING STARTED
Model BAT-24CM
About the Battery System
Locate Battery Housing
Identify Connector Ports
OPERATIONS MANUAL
Install Battery Fuses
USING THE BATTERY
Charge Battery
Planar Systems, Inc.
Set Up Power Management
MAINTAINING THE BATTERY
Replace Battery
Troubleshooting
APPENDIXES
Battery Disposal
Specifications
Streszczenie treści zawartej na stronie nr. 2
Planar Systems, Inc. © 2004. All rights reserved. QUICK LINKS Information in this document has been carefully checked for accuracy; however, no guarantee is Contents America Sales given to the correctness of the contents. This document is subject to change without notice. Planar Planar Systems, Inc. Index provides this information as reference only. Reference to other vendors’ product does not imply 1195 NW Compton Drive any recommendation or endorsement. Beaverton, O
Streszczenie treści zawartej na stronie nr. 3
QUICK LINKS Contents Contents Index Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Regulatory Compliance Product Information About the Invitium Battery System . . . . . . . . . . . . . . . . . . . . . . . 1 Warranty Locate the Battery Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GETTING STARTED Identify the Connector Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 About the Ba
Streszczenie treści zawartej na stronie nr. 4
QUICK LINKS Product Information Contents Warning Index Safety guidelines • Equipment is not suitable for use The Invitium battery system is designed to ensure both the highest level of Regulatory Compliance in the presence of a flammable product quality and safety for the user. To maintain both quality and safety, anesthetic mixture with air, Product Information follow the guidelines and instructions in this manual. oxygen, or nitrous oxide. • Use th
Streszczenie treści zawartej na stronie nr. 5
QUICK LINKS Cleaning guidelines Contents The Invitium battery system continues to operate normally while being cleaned in a fashion normal for a hospital environment. Use a damp, mildly soapy cloth to clean Index the exterior chassis. Drip protection is provided in accordance with the IPX1 rating, defined in the IEC/EN60529 standard. Regulatory Compliance Product Information Service support Warranty Other than battery installation and replacement, the Invitium battery system
Streszczenie treści zawartej na stronie nr. 6
QUICK LINKS About the Invitium Battery System Contents About the battery models As a component of the Planar Invitium medical workstation, the Invitium battery Index The model number scheme for the system is designed specifically for point-of care use. It is modular, compact, and battery system is BAT-xxyy, where xx ergonomically suited for effective utilization in the medical environment. Regulatory Compliance is the amp-hour rating of the battery The battery syst
Streszczenie treści zawartej na stronie nr. 7
QUICK LINKS Locate the Battery Housing Contents In operation The Invitium battery system ships already installed on the Invitium cart. The power Index Check that all cords and cables are cord, USB cable, and output power cable are connected, and the output power fuse securely connected before you turn is installed. You need to install the two battery fuses before operation. Regulatory Compliance on the Invitium workstation. Do not block the vent holes on Product Informatio
Streszczenie treści zawartej na stronie nr. 8
QUICK LINKS Identify the Connector Ports Contents All external connections to the battery system are located on the rear of the battery Legend Index enclosure. The design of the enclosure minimizes liquid ingress. 1 Standard IEC 120–250V AC input power Regulatory Compliance 2 A, 250 V replaceable Product Information 2 USB serial port Communication channel Warranty between the power supply and its host computer GETTING STARTED 3 12V DC 6 A output power About the Battery Sy
Streszczenie treści zawartej na stronie nr. 9
QUICK LINKS Install the Battery Fuses Contents About the battery fuses You need the two battery fuses and a screwdriver for this installation. Index The Invitium battery system requires To install a battery fuse two 6 A fuses. These are available Regulatory Compliance from any hardware store. 1 Push the fuse in until you feel the connection. Product Information Securing the fuse connection Use the screwdriver to turn the fuse Warranty holder approximately a quarter to
Streszczenie treści zawartej na stronie nr. 10
QUICK LINKS Charge the Battery Contents This section provides basic information on battery operations. See specifications on Index battery charging, charging controller board, and power consumption efficiency for more information. Regulatory Compliance Product Information Battery charging Plug the battery system into an AC power source for charging. Warranty GETTING STARTED Charge time About the Battery System The charging controller board is capable of independently ch
Streszczenie treści zawartej na stronie nr. 11
QUICK LINKS Battery discharging Contents You discharge the battery by (1) disconnecting the battery system from the AC power source and (2) powering the load. Index When the battery has been discharged for a long period of time, it reaches a point Regulatory Compliance at which it needs to cut off power to its load. The battery system communicates to the host computer and requests a safe shutdown or hibernation. Product Information Warranty Thermal protection The univers
Streszczenie treści zawartej na stronie nr. 12
QUICK LINKS Set Up the Power Management System Contents All communications occur through the USB serial interface. These are displayed Easier power management Index through the Windows Power Options Properties dialog box on the host computer. Unlike earlier Invitium battery systems, this system has no charge Regulatory Compliance To set up power management indicator panel. 1 Open the Control Panel and click the Power Options tool. Product Information The charge level ind
Streszczenie treści zawartej na stronie nr. 13
2 Click the Alarms tab on the Power Options Properties dialog box. QUICK LINKS Contents Low battery alarm Index User-selectable alarm that is audible or silent. The alarm is triggered when Regulatory Compliance the battery charge level reaches its low battery limit. Product Information Warranty Critical battery alarm User-selectable alarm that is audible or silent. The alarm is triggered when GETTING STARTED the battery charge level reaches its About the Battery
Streszczenie treści zawartej na stronie nr. 14
4 Select the notification you want, one of the two types or both. Click OK. QUICK LINKS Contents Alarm action Index An alarm action to hibernate or shut down can be selected in the Power Regulatory Compliance Options Properties menu. Product Information Alarm notification Warranty You must select a notification for the alarm you choose. Selecting an alarm action or running a program GETTING STARTED is optional. About the Battery System To set an alarm action: Locate Battery Housi
Streszczenie treści zawartej na stronie nr. 15
5 Open the Power Meter tab to check the power status of each battery. QUICK LINKS • Click the check box to see the details on a battery. Contents • Click a battery icon for more information. Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Locate Battery Housing Identify Connector Ports Install Battery Fuses USING THE BATTERY Charge Battery Set Up Power Management MAINTAINING THE BATTERY Replace Battery Troubleshooting APPENDIXES Battery Disposal
Streszczenie treści zawartej na stronie nr. 16
QUICK LINKS Replace the Battery Contents Replacement tips To remove the battery system from the cart The Invitium battery system weighs Index 1 Loosen the two screws on the front of the cart. 25 pounds. Handle it carefully. Regulatory Compliance 2 Loosen the screw on the back, and tuck the cables to the side. The unit is heavily weighted toward the front of the cart. As Product Information you remove it from the cart, you Warranty feel its heaviness. Once the unit is completely out of GETT
Streszczenie treści zawartej na stronie nr. 17
To replace the battery QUICK LINKS Contents 1 Loosen the two screws and remove the retaining bracket. Replacement tips Use only Yuasa NP 12-12 or Index B&B EP 12-12 batteries. Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Locate Battery Housing 2 Detach the four battery terminal cable connectors and move them to the side. Identify Connector Ports Install Battery Fuses USING THE BATTERY Charge Battery Set Up Power Management MAINTAINING THE BATTERY R
Streszczenie treści zawartej na stronie nr. 18
To reinstall the battery system into the cart QUICK LINKS Contents 1 Push the battery system all the way into the housing area. 2 Plug in the power cord, USB cable, and power output cable. Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Locate Battery Housing Identify Connector Ports 3 Reinsert the two battery fuses. Install Battery Fuses 4 Reinsert the three screws, one in the back and two in the front. USING THE BATTERY Charge Battery Set Up Po
Streszczenie treści zawartej na stronie nr. 19
QUICK LINKS Troubleshooting Contents Index Problem Possible Cause Possible Solution Regulatory Compliance The battery system not functioning, AC power is not connected. Make sure power cord is connected properly no output power, does not charge Product Information Input fuse needs to be replaced. Replace fuse in input connector. Replace when connected to AC power. with UL recognized fuse 2 A, 250 VAC, Warranty fast acting, size 5 mm x 20 mm. GETTING STARTED Over-temperature protection is acti
Streszczenie treści zawartej na stronie nr. 20
QUICK LINKS Battery Disposal Contents Industrial batteries contain lead and sulfuric acid, which are both considered Index “hazardous substances.” If batteries are improperly disposed of, for example, thrown in the trash or illegally dumped, these substances can eventually leak out and Regulatory Compliance contaminate the surrounding soil and groundwater supply. Product Information It is a federal law to properly dispose of lead-acid batteries once they can no longer be Warranty used. Once