Streszczenie treści zawartej na stronie nr. 1
TOA EX-16
INTERCOM SYSTEM
INSTALLATION HAND BOOK
TOA ELECTRIC CO., LTD.
KOBE, JAPAN
Streszczenie treści zawartej na stronie nr. 2
1. Introduction ...................................................... 1 1 2. Introduction of the EX-16 System............................... 1 2.1 Exchange................................................ 2.1.1 Features 2.1.2 Specifications 2.1.3 Further Details 2.1.4 System Block Diagram 2.2 Stations................................................... 7 2.2.1 Features 2.2.2 Specifications 2.3 Accessories ............................................ 8 2.3.1 Wall Mounting Panel (YC-100) 2.3.2 Talk
Streszczenie treści zawartej na stronie nr. 3
1. Introduction This is the installation manual for the exchange, stations and other components of TOA Intercom System EX-16. It includes an outline of the system, an explanation of installation, cable connection, inspection procedures and a troubleshooting guide. Careful study of this manual is recommended prior to installation of the system. This manual is only intended to give the information necessary for proper installation of the system. Prior to installation of the system, unpack the comp
Streszczenie treści zawartej na stronie nr. 4
2.1.2 Specifications The exchange is available with the following specifications. EX-16 Capacity: 16 lines max. (with paging function) Dimensions: 360(W) X 300(H) X 100(D)mm (14.2" X 11.8" X 3.9") Weight: 8.3 kg (18.3 lbs.) with 16 lines Exchange capacity can be increased within the given limits in units of 4 lines. Exchange Specifications Ambient Temperature Range: 32°~104° F (0°~40°C) Audio Input Level: +7dBm max. Audio Output Level: +30dBm max. Bandwidth: 200Hz~10KHz Crosstalk: -60dB/1.5KHz S
Streszczenie treści zawartej na stronie nr. 5
(a) Structure of Exchange and Names of Parts Line Amp Unit (LAU-16) Central Processing Unit (CPU-16) Terminal for Station EX-16 DIMENSIONS in mm Connector n Short Bar Power Transformer Terminal AC Fuse Holder DC Fuse Holder Power Indicator Voltage Selector Power Switch AC/DC Input Terminal — Power Supply Module (DSM-16) Mother Board 3
Streszczenie treści zawartej na stronie nr. 6
dial data input link control (b) CPU (Central Processing Unit) The Central Processing Unit is divided into two sections: common control and speech path. Common control: This section consists of a microcomputer and associated other circuits. It controls receiving dial data from stations, opening and closing of speech path, controlling of signal, paging and BGM switches in accordance with the exchange program. Speech path: This section consists of a voice switching circuit, signal generator, link
Streszczenie treści zawartej na stronie nr. 7
BGM/AII call/Link busy (c) LAU (Line Amplifier Unit) The Line Amplifier Unit consists of a power supply circuit for stations, transmitting and receiving circuits for voice signal, speech path switches, BGM switches and the dial data receiving circuits. One unit accepts up to 4 stations. A maximum of 4 LAU's can be installed. switch receiving transmitting switch circuit T R circuit control signal dial data in dial receiver out (d) DSM (Power Supply Module) The Power Supply Module consists of a po
Streszczenie treści zawartej na stronie nr. 8
(e) Integral Terminal for Connecting Stations The connection terminal for the exchange and stations is built into the exchange and connected to each LAU with a mother board. (Wiring of the terminal and the station will be explained in a separate section.) 2.1.4 System Block Diagram A block diagram of the EX-16 system is shown below. In a standard system, at least one LAU-16 is installed. The remaining units are optional. Each LAU-16 contains the necessary circuitry for four stations. Station Ter
Streszczenie treści zawartej na stronie nr. 9
2.2 Stations 2.2.1 Features The stations used in the Toa Intercom EX-16 have the following features: 1. Each station is provided with a male 4-pin plug (YC-102) for easy con- nection to cables. 2. Wiring from the exchange to each station is an independent 4-wire system. The fact that only 4 wires are necessary makes installation easier, and with a 4-pin jack (YC-101 or YC-103) at the end of each cable, connection can be made quickly with only a screwdriver. There are three types of stations avai
Streszczenie treści zawartej na stronie nr. 10
Station Specifications Permissible Loop Resistance: 300 ohms Input/Output Impedance: 600 ohms (balanced) Loudspeaker Output: 300mW maximum Handset Speaker Output: 100mW maximum 2.3. Accessories 2.3.1 Wall Mounting Panel (YC-100) The wall mounting panel is used for HFM-100 and HFS-100 when these stations are to be surface wall-mounted. 2.3.2 Talk-Back Unit (TKU-11) This unit, optional amplifier (10W max.) and speaker (Hi-Z) will allow high- volume paging with response from speaker. Conversations
Streszczenie treści zawartej na stronie nr. 11
1. Power Switch SPECIFICATIONS 2. Power Indicator Power Source: 100~120/200~240V AC 3. Output Volume Control Talk-Back Max. 30 dBm, Input: 4. Input Volume Control 5. Rubber Foot Amplifier Max. 10W, Hi-Z 6. AC Inlet Talk-Back Max. 10dBm, Output: 7. Voltage Selector Amplifier 0dBm, 8. 8-Pin Terminal Board 9. Output Jack Control: Voice Switching 10. Terminal Board Cover Voice Switch or Press-To-Talk Speech Control: S/N 55dB 204 X 202 X 98mm Dimensions: 2kg Weight: 9
Streszczenie treści zawartej na stronie nr. 12
3. Installation of the EX-16 System 3.1 Precautions for Installation 3.1.1 Exchange Pay particular attention to the following points: * The layout should allow easy servicing and inspection. * The exchange is compact and lightweight; however, it is important to ascertain the strength of the wall on which it will be placed. * The exchange should be grounded. When it is used in combination with other systems (for example, with a PA system) the exchange should be connected to the other components
Streszczenie treści zawartej na stronie nr. 13
3.1.2 Stations Particular attention should be given to the following points during installation. * A desk-type, wall-mounting-type or desk/wall-type should be chosen according to the user's need. * If the all-call paging or talk-back function is adopted, precautions should be taken to ensure against feedback due to interference between the station (microphone) and the paging or talk-back speaker; that is, they should be installed facing different directions or separated as far as possible from e
Streszczenie treści zawartej na stronie nr. 14
3.2 Cable Installation Wire type, number of wire pairs and number of individual wires are to be determined for individual sections of the wiring system according to the guidelines set down below. * 4-wire twisted pair cables are to be used for wiring between indoor terminal boards, intermediate terminal boards, main terminal boards, etc. * Outdoor wires should be used where wiring passes through inaccessible areas such as in ceilings or under floors. Indoor wires may also be used, however, in ca
Streszczenie treści zawartej na stronie nr. 15
3.4 Wiring General Information * Wiring should be done independent of public telephone lines. * The wiring conduit is often installed underground or embedded in building structures such as walls and floors, so care should be taken to draw up a wiring plan that has ample reserve for future extension of the system and that can be adapted to future remodelling or expansion of the building it is housed in. Wiring systems must be planned with ample wires, a conduit and with provisions for additions t
Streszczenie treści zawartej na stronie nr. 16
3.5 Piping * Where wiring is to be passed through a wall or the like, it should be protected by a hard PVC or metal tube. * If the number of connecting wires between an indoor terminal board and a station is small and the station's site is fixed so that it will not be moved frequently, install a box at that site and pull wiring through a metal or hard PVC tube as required by job or ordinance. * Use a floor duct if the number of connecting wires is large and the stations are likely to be moved fr
Streszczenie treści zawartej na stronie nr. 17
3.6 Connection between the station and the exchange Station 4-Pin Plug (YC-102) Plug in (Cover) 4-Pin Jack (YC-101) (YC-103: 4-Pin Jack for flush-mount) NOTE: Use 4" X 2" Switch Box for YC-103. Receiving Lines (not Polarity Specified) Transmitting Lines (not Polarity Specified) (Viewed from the station side) 15
Streszczenie treści zawartej na stronie nr. 18
Clipping Tool C (YC-105) Note: Connect the individual cables in order, starting with the top ter- minal. When using the clipping tool, be sure that the cutting edge is on the side of the wire to be cut off. Push down Cutting edge Clip Terminal Clip Terminal (Side View) 16
Streszczenie treści zawartej na stronie nr. 19
TERMINAL BOARD EX-16 WIRING INSTRUCTIONS 1 STATION CONNECTIONS or 2 TALK-BACK CONNECTIONS TKU-11 TERMINAL SPEAKER LINE INPUT 17
Streszczenie treści zawartej na stronie nr. 20
3.7 AC/DC Power Supply Connection A 5P terminal for AC and DC power supply is provided on the DSM-16. The power cable, YA-308 or YA-309, can be connected to the 5P terminal. Be sure to ground the exchange. Power Supply Cables 5P Terminal on DSM-16 YA-308 YA-309 3.8 Connection of the Input/Output Terminal A 6P terminal for the input/output signals of the EX-16 is provided on the DSM-16. 6P Terminal (DSM-16) BGM IN 50K UNBAL PAGING OUT 600 UNBAL 0dB REMOTE OUT MAX 125 VA 18