Streszczenie treści zawartej na stronie nr. 1
SeaEra Toilet
OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this
product. Equipment damage, injury to personnel or death could result from improper installation.
Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment,
injury or death to
Streszczenie treści zawartej na stronie nr. 2
Press push-button switch and hold until all waste is cleared from the toilet bowl. No special toilet paper is required. Water should appear in the bowl within ten seconds. If not, see troubleshooting section. Hard objects or stringy substances (paper towels, feminine hygiene products, filter cigarettes, etc.) must not be thrown into the toilet as they will cause damage. Always shut off seacock(s) before leaving the boat unattended. Young children should NOT be left unsupervised around t
Streszczenie treści zawartej na stronie nr. 3
MAINTENANCE C.P. Cleaning Instructions IMPORTANT: Do not use cleaners that contain ammonia, ethyl acetate, phosphoric acid or concentrated chlorine bleach. These may cause damage to the toilet. Using C.P. a bio-enzymatic toilet bowl cleaner (available from Raritan Engineering) will keep the bowl clean and fresh smelling. Recommend Visual Inspection ✔ For leaks at toilet and hose connections ✔ Hose clamps ✔ Condition of hoses ✔ Seacocks ✔ Condition of wires and connections ✔ In-Line Strainer (
Streszczenie treści zawartej na stronie nr. 4
IMPORTANT • Improper winter lay up is a major cause of marine toilet failure. Use only nontoxic antifreeze. Flush toilet several times to clear waste from system. Dispose of all antifreeze in accordance with local and federal regulations. Winterize holding tanks, plumbing, treatment systems (MSD’s), etc. independently following manufacturer’s instructions. Pressurized Freshwater Models Pressurized Freshwater Model Parts Required 1" (25mm) or 1 1/2" (38mm) I.D. discharge Nontoxic hose,
Streszczenie treści zawartej na stronie nr. 5
WINTERIZING Integral and Remote Intake Pump Models Parts Required Sea Water Model (Integral Pump) 3/4" (19mm) I.D. intake hose approximately 3 feet Nontoxic (1m) long. Antifreeze 1" (25mm) or 1 1/2" (38mm) I.D. discharge hose approximately 3 feet (1m) long. Two buckets Nontoxic antifreeze approximately 1 quart (1 liter) Steps 1. Close the intake and discharge seacocks. 2. Turn off power to unit. 3. Disconnect and drain intake hose, discharge hose and In-Line Strainer. 4. Connect short hoses to t
Streszczenie treści zawartej na stronie nr. 6
Pressurized Freshwater or Remote Sea Water Model Integral Sea Water Model 19 3/4" (52.1cm) Household 14 3/8" (36.5cm) Household 19 3/4"(50.2cm) Household 17 1/2" (44.5cm) Marine 13" (33cm) Marine 16 3/4"(42.6cm) Marine 14 7/8" 14 7/8" (37.8cm) (37.8cm) Household Household 14 1/2" 14 1/2" (36.8cm) (36.8cm) Marine Marine 13 3/8" (34cm) 6 5/8" (16.8cm) 11 1/8" (28.3cm) Plumbing Maximum suction of Intake pump 4 Ft. (1.2m) from Intake Pump. CONVERSIONS (Maximum height above waterline) 2 Wire - AWG to
Streszczenie treści zawartej na stronie nr. 7
INSTALLATION Parts Included Additional Parts Required Four stainless steel mounting bolts or lag All Complete Toilets screws (minimum 1/4" [6mm]) and washers Toilet Bowl 1" (25mm) or 1 1/2" (38mm) I.D. discharge hose Seat and Cover 3/4" (19mm) I.D. reinforced intake hose Lower Base Assembly 3/4" (19mm) and 1" (25mm) or 1 1/2" (38mm) Motor Cover hose clamps (two for each connection below Push Button Switch waterline) Sea Water Model Wire 3/4" Hose Barb - straight fitting (2) Terminals
Streszczenie treści zawartej na stronie nr. 8
90° Rotation of Toilet Bowl Toilet bowl can be rotated 90° on the base, for installing in confined locations. NOTE: SeaEra Models with Integral Pump: Replace existing hose from the intake pump to the toilet bowl with a longer hose. 1. Determine which direction bowl is to be mounted. 2. Remove hose at back of toilet (Sea Water Model with Integral Pumps ONLY). 3. Remove four vinyl caps at the base of toilet bowl. 4. Remove four nuts and shoulder washers. 5. Carefully remove toilet bowl from base.
Streszczenie treści zawartej na stronie nr. 9
INSTALLATION Mounting Water Solenoid Valve (Pressurized Freshwater Models Only) 1. Locate valve on a solid flat surface in an area that is dry and well ventilated. 2. Mark and drill holes for water solenoid mounting bracket. NOTE: Hole size will depend on type of bolts/screws used (1/4" [6mm] size bolt/screws are recommended). 3. Mount bracket. From Pressurized 4. Install fittings provided (PLA7) on valve’s inlet Freshwater and outlet ports. Source 5. Attach valve to bracket. hoses must be ins
Streszczenie treści zawartej na stronie nr. 10
Pressurized Freshwater Model PLUMBING Installed Above Waterline WARNING: Hazard of Flooding Vacuum Toilets mounted at or below the waterline SeaEra Breaker Toilet must have a vented loop installed in the Water discharge line. The top of the vented loop Solenoid must be a minimum of 4" (10cm) above Valve Waterline Waterline the waterline at the boats greatest angle Discharge of heel (see vented loop manufacturer’s Shut off Holding Tank instructions). Valve Sea Water Models must also have a vent
Streszczenie treści zawartej na stronie nr. 11
INSTALLATION Intake Lines From Pressurized Freshwater Source Pressurized Freshwater Models (Shut Off Valve) Install a shut off valve in intake line before water solenoid valve. 1. Connect hose from shut off valve to inlet port of water solenoid valve. IN NOTE: To avoid malfunction of water solenoid due to debris in water, installation of Freshwater OUT Strainer (190601) is recommended. 2. Connect hose from outlet port of water solenoid valve to inlet port of vacuum breaker. To Inlet Port of Vacu
Streszczenie treści zawartej na stronie nr. 12
WIRING Pressurized Freshwater Wiring WARNING: Hazard of Shock and Fire Always use proper wire, wire connectors and fuse/circuit breaker. See Specification Push Button Chart. Switch Secure wire properly. 3 Amp Do not connect appliances to toilet circuit. Fuse Make sure power is off before proceeding. Use proper wire terminals for all wire Solenoid Fuse or connections. Orange Circuit Valve POS (+) 1. Determine proper wire size by measuring Breaker Black distance from: NEG (-) NEG POS
Streszczenie treści zawartej na stronie nr. 13
TROUBLESHOOTING TROUBLESHOOTING WARNING: HAZARD OF ELECTRIC SHOCK - Before beginning any work on the SeaEra, be sure that all power to the unit has been turned off. WARNING: HAZARD OF FLOODING - Make sure seacocks are in the CLOSED or OFF position before working on toilet. NOTE: The following information reflects the most probable causes and solutions to problems although not every possible cause and solution is provided. Any questions regarding servicing or operation of the SeaEra should be dir
Streszczenie treści zawartej na stronie nr. 14
SeaEra PARTS LIST Part No. Description Part No. Description 1108A Macerator Nut 162100W Upper Housing Assembly 162200W Middle Housing Assembly 1222AW 90° Discharge Fitting 162300W Lower Housing Assembly 1226 Mounting Screw (4) 163000 Inline Strainer 1226B 1/4-20 Hex Nut (4) 164000 Push Button Switch 1234 Bowl Gasket 31-102 Shaft Seal 1236AW Bowl Spud Assembly 41-260 Bowl Elbow (Freshwater Models Only) 1236E Bowl Elbow C254 Joker Valve 1237 Marine-size Bowl CH38 1/4-20 Threaded Stud (4) 1244 Hous
Streszczenie treści zawartej na stronie nr. 15
EXPLODED PARTS SeaEra Exploded Parts View 1244 or 1237 SOLENOID VALVE CWPS*A PLA7 1236AW PLA7 VCAP 1226B CWPSMB RNI ATMOSPHERIC 1234 VACUUM BREAKER PLAVB0-5 1236E PLA6 CH38 PLA5 161135 or 161140 PLA7 161105 C254 161130 161107 164000 161125 1108A 161123 HW1 M23A 161120 F164 1226 31-102 1222AW 161115 161110 F005 1660* 1610* 162325A 163000 F020 162305 162320 162310 162410 162300W 162315 162420 162425 162225 162135 162415 162200W 162425 162420 190601 - Recommended for use with F144 162425 Freshwater
Streszczenie treści zawartej na stronie nr. 16
LIMITED WARRANTY Raritan Engineering Company warrants to the original purchaser that this product is free of defects in materials or workmanship for a period of one year from the product’s date of purchase. Should this product prove defective by reason of improper workmanship and/or materials within the warranty period, Raritan shall, at its sole option, repair or replace the product. 1. TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with a detailed description