Streszczenie treści zawartej na stronie nr. 1
Lighting Systems Baselyte-BSL28
Page of 8 4 Light T5 HO Indirect
Weight = 3.0 lb./ft
Ordering Information
Family Distribution Lamp Type No. of Lamps Housing Module Length Wiring Voltage Ballast Finish
BSL 3 H 04 EN
H = T5 HO 04 = 4 Light
3 = Indirect EN = Solid 04 = 4’ C = Custom Color
E = Standard
1 = cct. D = Dual 20V
08 = 8’ W = Standard
<0% THD
2 = 2cct. & 277V
12 = 2’ White
F = Standard
3 = cct. w/EC/NL 1 = 20V
<0% THD
4 = 2cct. w/EC/NL 2 = 277V
w/fusin
Streszczenie treści zawartej na stronie nr. 2
Lighting Systems Baselyte-BSL28 Page 2 of 8 4 Light T5 HO Indirect Performance COEFFICIENTS OF UTILIZATION COEFFICIENTS OF UTILIZATION Candlepower Curve Candlepower Summary Coefficients of Utilization CANDLEPOWER SUMMARY % EFFECTIVE CEILING CAVITY REFLECTANCE ZONE CANDLEPOWER % EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 DEG. 0 22.5 45 67.5 90 80 70 50 % WALL REFLECTANCE 180 4753 4753 4753 4753 4753 % WALL REFLECTANCE 50 30 10 50 30 10 50 30 10 175 4727 4734 4754 4768 4772 50 30 10 50 3
Streszczenie treści zawartej na stronie nr. 3
Lighting Systems Baselyte-BSL28 Page 3 of 8 4 Light T5 HO Indirect Mounting Options Mount Type: T-Bar 15/16” (On-Grid)* 1-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’ 3 Conductor BSLM6102P13 BSLM6104P13 BSLM6108P13 BSLM6112P13 4 Conductor BSLM6102P14 BSLM6104P14 BSLM6108P14 BSLM6112P14 7 Conductor BSLM6102P17 BSLM6104P17 BSLM6108P17 BSLM6112P17 • 65 lbs maximum load • Canopy: Diameter of 3 3/4“x 7/32” BSLM6102N BSLM6104N BSLM6108N BSLM6112N Non-Power Mount •
Streszczenie treści zawartej na stronie nr. 4
Lighting Systems Baselyte-BSL28 Page 4 of 8 4 Light T5 HO Indirect Mount Type: T-Bar Fixed Position (1/4-20 Threaded Rod) 1-Power Mount 2-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’ 3 Conductor BSLM2102P13 BSLM2104P13 BSLM2108P13 BSLM2112P13 4 Conductor BSLM2102P14 BSLM2104P14 BSLM2108P14 BSLM2112P14 • Meets UBC, OSHPD and DSA seismic requirements 2-Power Mount • Canopy: Diameter of 5 /4“x 3/4” (power) BSLM2102P23 BSLM2104P23 BSLM2108P23 BSLM2112P23 3 Co
Streszczenie treści zawartej na stronie nr. 5
Lighting Systems Baselyte-BSL28 Page 5 of 8 4 Light T5 HO Indirect Mount Type: Non-Accessible Ceilings (concrete, gypsum etc.) 1-Power Mount 2-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’ 3 Conductor BSLM1102P13 BSLM1104P13 BSLM1108P13 BSLM1112P13 4 Conductor BSLM1102P14 BSLM1104P14 BSLM1108P14 BSLM1112P14 • Meets UBC, OSHPD and DSA seismic requirements 7 Conductor BSLM1102P17 BSLM1104P17 BSLM1108P17 BSLM1112P17 /4 3/4 • Canopy: Diameter of 5 “x ” (power)
Streszczenie treści zawartej na stronie nr. 6
Lighting Systems Baselyte-BSL28 Page 6 of 8 4 Light T5 HO Indirect Wiring Options: 1 Circuit 1 Circuit Type 1: cct. Type 8: cct. w/cct. thru wire Type H: cct. w/2cct. thru wire Type 7: cct. w/dimming All lamps wired on one circuit. 1 Circuit with Emergency Circuit/Night Light (EC/NL) Type 3: cct. w/EC/NL One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal circuit and EC/NL circuit wired to fixture ends. All la
Streszczenie treści zawartej na stronie nr. 7
Lighting Systems Baselyte-BSL28 Page 7 of 8 4 Light T5 HO Indirect Wiring Options: 2 Circuit Center/Outer Switching 2 Circuit Center/Outer Switching Type 2: 2cct. Type 9: 2cct. w/cct. thru wire Type I: 2cct. w/2cct. thru wire Fixture wired for two circuit. Lamps wired for center/outer switching. 2 Circuit Center/Outer Switching with Emergency Circuit/Night Light (EC/NL) Type 4: 2cct. w/EC/NL One 4’ section in two circuit fixture (center/outer switching) to be wired on
Streszczenie treści zawartej na stronie nr. 8
Lighting Systems Baselyte-BSL28 Page 8 of 8 4 Light T5 HO Indirect Wiring Options: 2 Circuit A/B Switching (alternate 4’ sections) 2 Circuit A/B Switching (alternate 4’ sections) Type B: 2cct. Type A: 2cct. w/cct. thru wire Type S: 2cct. w/2cct. thru wire Fixture wired for two circuit. Lamps wired for A/B switching in alternate 4’ sections. 2 Circuit A/B Switching (alternate 4’ sections) with Emergency Circuit/Night Light (EC/NL) Type C: 2cct. w/EC/NL One 4’ section i