Streszczenie treści zawartej na stronie nr. 1
VEC022APC
Jump-Start System
260 PSI AIR COMPRESSOR • 12 VOLT DC POWER SUPPLY
OWNER’S MANUAL
& WARRANTY INFORMATION
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION,
MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USING, READ AND UNDERSTAND
ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S
BATTERY MANUFACTURER GUIDELINES. FAILURE TO DO SO COULD RESULT IN INJURY AND/
OR PROPERTY DAMAGE.
4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312
TEL: 954-584-4446 •
Streszczenie treści zawartej na stronie nr. 2
CONTENTS 1. INTRODUCTION ....................................................................................... 5, 6 2. USING VECTOR JUMPER AS A JUMP-START SYSTEM ................................ 7 2.1 Easy, Step-by-Step Jump-starting Instructions ................................... 8 3. CHARGING/RECHARGING ........................................................................ 9 3.1 110/120 Volt AC Charging ................................................................ 9 3.2 12 Volt DC Char
Streszczenie treści zawartej na stronie nr. 3
SAFETY INFORMATION WARNING: (Warning statements identify conditions or practices that may result in personal injury or loss of life) 1) When working with lead acid batteries, always make sure immediate assistance is available in case of accident or emergency. 2) Always use protective eyewear when using this product: contact with battery acid may cause blindness and/or severe burns, be aware of first aid procedures in case of accidental contact with battery acid. 3) There is a risk of explosive g
Streszczenie treści zawartej na stronie nr. 4
IMPORTANT: Although this unit is delivered in a partially charged state, you must fully charge it with the supplied 110/120 Volt AC charger for a full 24 hours before using it for the first time. You cannot overcharge the unit using the AC charger method. 1) Use only the supplied cords/adapters for recharging this unit. Do not recharge for more than 3-4 hours maximum using 12 Volt DC method. Recharge unit after each use. 2) All On/Off switches should be in the OFF position when the unit is charg
Streszczenie treści zawartej na stronie nr. 5
1. INTRODUCTION Congratulations on selecting the VECTOR® JUMP-STARTER, AIR COMPRESSOR and 12 VOLT DC POWER SUPPLY. This compact jump-starter is unique in the amount of energy it can supply for its size. The internal battery is a high density sealed, lead-acid battery that stores and delivers energy comparable to full sized ordinary jump-starters. Please read this guide carefully before use to ensure optimum performance and avoid damage to the unit or items that you are using it with. A standard
Streszczenie treści zawartej na stronie nr. 6
1 9 3 2 3 12 13 10 5 6 7 4 8 15 11 16 14 FIGURE 1A (FRONT VIEW) FIGURE 1B (REAR VIEW) 1. Reverse connection indicator 2. Good connection indicator 3. 12 Volt DC Accessory Socket with 20 amp overload protection 4. Battery Level Push Button 5. LED Charging/Battery Level Indicators 6. Heavy-Duty Welding Quality Jumper Cables 7. Heavy-Duty Copper Clamps 8. Exclusive Quick-Release Clamp Holsters 9. 110/120 Volt UL approved AC/DC Charging Adapter 10. 12 Volt DC/DC Charging Adapter 11. Built-in CCFL Em
Streszczenie treści zawartej na stronie nr. 7
2. USE AS A JUMP-START SYSTEM WARNING: 1. Before using this system to jump-start any vehicle or boat, read and understand all instructions, safety tips, warnings, cautions and first aid information provided in this manual and on the product labeling. Additional important information may also be provided by the vehicle’s battery system manufacturer. 2. Be aware of first aid procedures before attempting jump-start procedure. 3. Always wear protective eyewear when working with a lead acid-type batt
Streszczenie treści zawartej na stronie nr. 8
2.1 EASY, STEP-BY-STEP JUMP-STARTING INSTRUCTIONS This jump-starter is equipped with an automatic safety switch that only allows jump-start energy to flow when proper connections are made to battery and frame. The automatic switch works in conjunction with an audible reverse polarity alarm and a large red LED. If inadvertent reverse polarity occurs, the alarm will sound and the red LED will light. Disconnect the black clamp (negative clamp) first, then the red clamp. Reconnect properly and a gr
Streszczenie treści zawartej na stronie nr. 9
• Always use protective eyewear when using this product: contact with battery acid may cause blindness and/or severe burns • Keep out of children’s reach • ALWAYS store battery clamps in built-in holsters when not in use and never touch battery clamps together, this can cause dangerous sparks, power arcing and/or explosion FIRST AID: • SKIN: If battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly with soap and water. If redness, pain, or irritation occurs,
Streszczenie treści zawartej na stronie nr. 10
3.2 12 VOLT DC CHARGING 1. Insert one end of the DC/DC charging adapter into a 12 Volt DC accessory receptacle on the vehicle or boat. 2. Insert the plug at the other end of this charging adapter into the 12 Volt DC accessory socket receptacle on the front of the unit. 3. Charge the unit until the green FULL indicator lights when Charge Switch Indicator Button is pressed. DO NOT EXCEED 3-4 HOURS MAXIMUM. 4. When charging is completed, remove the power cord and store in a safe place. 3.3 ESTIMATE
Streszczenie treści zawartej na stronie nr. 11
5. EMERGENCY WORKLIGHT The Worklight is controlled by an On/Off switch. Make sure the lamp is turned OFF when the unit is being recharged or stored. The lamp is efficient and will operate up to 114 hours on a full charge. The CCFL lamp’s operating life is 100,000 hours. 6. AIR COMPRESSOR/TIRE INFLATOR IMPORTANT: Read Instructions Carefully To Avoid Possible Injury Or Property Damage. The built-in 12 Volt DC air compressor is the ultimate compressor for all vehicles, trailer tires and recreationa
Streszczenie treści zawartej na stronie nr. 12
6.2 TIRE INFLATION OR PRODUCTS WITH A VALVE STEM 1. Place connector (chuck) on valve stem. 2. Push connector toward valve stem and close thumb latch. 3. Make sure connector is pushed onto valve stem as far as possible before closing thumb latch. 4. Check pressure with the pressure gauge. 5. When desired pressure is reached, turn OFF Compressor Power Switch. 6. Open thumb latch and remove connector from valve stem. 7. Store compressor hose and tire fitting in storage compartment. IMPORTANT: Alwa
Streszczenie treści zawartej na stronie nr. 13
7. REPLACEMENT PARTS For replacement parts (bulbs, batteries, fuses, etc.), contact Vector Customer Service: (954) 584-4446 or toll-free (866) 584-5504. 7.1 CCFL CCFL lamp is designed for 100,000 hours of operation. It is not user replaceable. 7.2 BATTERY REPLACEMENT It is recommended that the unit be returned to Vector Customer Service for battery replacement: Contact (954) 584-4446 or toll-free (866) 584-5504. WARNING: • Do not dispose of the battery in fire as this may result in an explosion
Streszczenie treści zawartej na stronie nr. 14
TWO YEAR LIMITED WARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, Ltd., regarding this product. There is no other warranty, other than those described herein. This Vector Manufacturing, Ltd. product is warranted, to the original purchaser only, to be free of defects in materials and workmanship for two years from the date of purchase without additional charge. The warranty does not ex
Streszczenie treści zawartej na stronie nr. 15
15 Manual 022APC 15 12/20/02, 8:40 PM
Streszczenie treści zawartej na stronie nr. 16
© 2002 VECTOR MANUFACTURING, Ltd. FT. LAUDERDALE, FL 33312 MADE IN CHINA 112202 16 Manual 022APC 16 12/20/02, 8:40 PM