Streszczenie treści zawartej na stronie nr. 1
™
Home Cinema Power Protection with PureFilter Technology
Power Console PF30
User Manual
AP20500ea3M
AP20500ea3M-BLK
Streszczenie treści zawartej na stronie nr. 2
Belkin Power Console Table of Contents P age In tr oduction ......................................................................................... 2 S af e t y Pr ec autions ............................................................................ 3 P ack age C on t en t s .............................................................................. 4 P o w er C ons ole F e at ur e s .................................................................... 5 Hook up and Ins t
Streszczenie treści zawartej na stronie nr. 3
Belkin Power Console Introduction Thank you for purchasing the Belkin Power Console. The Power Console is designed to clean, protect, and efficiently distribute power to your valuable home cinema system. The Belkin Power Console ensures that every movie you watch and every album you hear is as clean and clear as possible. The Power Console is packed with innovative features to provide you with the best home cinema experience. Ordinary household AC power that is delivered to your home is p
Streszczenie treści zawartej na stronie nr. 4
Belkin Power Console Safety Precautions W arning – E ar thing This product must be plugged directly into an earthed AC power socket. Do not plug or “daisy-chain” this product into other electrical products such as surge protectors, power strips, or UPSes. Do not plug this product into an extension cable. Failure to plug this product directly into an earthed socket may result in personal injury or damage to your equipment, and void your Belkin Connected Equipment Warranty. Call a licensed
Streszczenie treści zawartej na stronie nr. 5
Belkin Power Console Safety Precautions W arning – P o w er C able S af e t y Do not route the Power Console’s AC power cable near heat sources. This could damage the power cable and cause it to malfunction, creating a shock hazard. Do not route the Power Console’s AC power cable in heavy foot-traffic areas where it could create a trip hazard (hallways, doorways, across room). If the power cable is frayed, ripped, cut, or damaged in any way, please discontinue use immediately and ref
Streszczenie treści zawartej na stronie nr. 6
Belkin Power Console Power Console Features 1. S wit ched B ut t on - turns on and off the power to the Power Console’s “switched” sockets 2. C en tr al LED Displa y - monitors the Power Console’s vital functions 3 . V ideo Filt er - ensures optimum reduction of line noise and interference to your video components (single-stage analog filter) 4 . A udio Filt er - ensures optimum reduction of line noise and interference to your audio components (single-stage analog filter) TM
Streszczenie treści zawartej na stronie nr. 7
Belkin Power Console Hookup and Installation S t ep 1 Moun ting y our P o w er C ons ole ( Op tional) The Belkin Power Console can be mounted to a standard AV equipment rack or inside a cabinet equipped with an equipment rack. A. Remove the mounting brackets from the box. B. Mak e sure that the Power Console is unplugged. C. Align the bracket with the front of the Power Console for flush installation in the rack. D. Attach the bracket to the side of the Power Console (Fig.
Streszczenie treści zawartej na stronie nr. 8
Belkin Power Console Hookup and Installation S t ep 2 C onnect V ideo C omponen t s t o the V ideo Filt er The Belkin Power Console contains an isolated video filter that is optimised to clean and condition the power to all of your video components. The video filter also isolates your video components from connected audio and high-current audio components. A. Attach Belkin power cable labels to each component’s power cable before you plug the cable into the sockets on the Pow
Streszczenie treści zawartej na stronie nr. 9
Belkin Power Console Hookup and Installation S t ep 3 C onnect A udio C omponen t s t o the A udio Filt er The Belkin Power Console contains an isolated audio filter that is optimised to clean and condition the power to all of your audio components. The audio filter also isolates your audio components from connected video and high-current audio components. A. Attach Belkin power cable labels to each component’s power cable before you plug the cable into the sockets on the Power
Streszczenie treści zawartej na stronie nr. 10
Belkin Power Console Hookup and Installation S t ep 4 C onnect High-C urr en t A udio Filt er (8- S ec ond Dela y ) The HiCurrent socket is specifically designed to filter out AC line noise while delivering maximum current to power-hungry amplifiers and other high-current audio components. No t e: The HiCurrent socket is equipped with an eight-second delay. This allows your high-current amplifiers to turn on last and turn off first, avoiding that annoying and potentially damagi
Streszczenie treści zawartej na stronie nr. 11
Belkin Power Console Hookup and Installation S t ep 5 C onnect y our P a y -P er - V ie w /Phone Line Your Belkin Power Console comes equipped with Pay-Per-View/phone- line protection with a built-in splitter. These are standard BT RJ11 phone ports and are labeled “Phone”. A. Connect one end of your telephone cable to the wall port to which you normally connect your phone line. Connect the other end of your telephone cable to the Power Console phone port labeled “IN”. B. Connect
Streszczenie treści zawartej na stronie nr. 12
Belkin Power Console Hookup and Installation S t ep 6 C onnect y our C able TV / S at ellit e C o axial Line s Your Belkin Power Console comes with two pairs of F-type coaxial-cable connections, and one pair of aerial-cable connections to protect your system from dangerous electrical disturbances that can travel down your cable/satellite/aerial-signal lines. You will need additional coaxial cables to connect the Power Console to your home cinema components. A. S at ellit e (D
Streszczenie treści zawartej na stronie nr. 13
Belkin Power Console Hookup and Installation S t ep 7 C onnect y our Br o adb and E therne t Line Your Belkin Power Console comes equipped with broadband Ethernet-line protection. These are standard RJ45 Ethernet ports and they are labeled “Network”. A. C onnect one end of an RJ45 network patch cable to a network port (either directly to a router or wired network wall port). Connect the other end of the network patch cable to the network port labeled “IN”. B. Connect one end of
Streszczenie treści zawartej na stronie nr. 14
Belkin Power Console Operation C en tr al LED C on tr ol P anel The Belkin Power Console is equipped with an LED display that monitors the vital functions of the Power Console. A. S wit ched ON Indic at or Ligh t – indicates that the “Switched” sockets are receiving power. B. W iring OK Indic at or Ligh t – indicates whether the AC socket to which the Power Console is connected is wired properly, or cross-wired. If the “Wiring OK” indicator does not light, then the live an
Streszczenie treści zawartej na stronie nr. 15
Troubleshooting P o w er C ons ole is no t pr o viding po w er . • Check to ensure that the Power Console is plugged into a properly earthed AC wall socket. Some sockets require a wall switch to be turned on in order to deliver power to the socket. • Too many devices may be plugged into the Power Console, which are overloading the unit and tripping the overload circuit breaker. The Power Console is not designed to handle current loads larger than 10 Amps or 2400 watts. Try unplugging
Streszczenie treści zawartej na stronie nr. 16
Belkin Power Console Troubleshooting W iring OK indic at or ligh t is no t lit . • Check to make sure that the Power Console is plugged into an earthed AC wall socket. Do not use any plug adapters. • This indicates that the live and neutral (L–N) wires are reversed. Unplug the Power Console and consult an electrician. F or all o ther t echnic al que s tions or tr ouble shoo ting is sue s , ple as e c on t act B elkin C us t omer S er vic e 00 800 2 2 3 5 5460 . Glossa
Streszczenie treści zawartej na stronie nr. 17
Belkin Power Console Belkin Connected Equipment Warranty Belkin Limited warrants to the original consumer or other end-user of any Belkin Power Console for the life of the product, that the Belkin Power Console shall be free of defects in design, assembly, material or workmanship and will repair or replace, at its option, any defective Belkin Power Console free of charge. Belkin Limited will repair or replace, at its option, any equipment (“connected equipment”) that is damaged by a tra
Streszczenie treści zawartej na stronie nr. 18
Belkin Power Console Belkin Connected Equipment Warranty All warranties provided herein are null and void if the Belkin Power Console has been improperly installed, altered in any way, tampered with, or if the connected equipment was not used under normal operating conditions or in accordance with any labels or instructions. All Belkin Power Consoles must be plugged directly into the power source and must not be “daisy-chained” together in serial fashion with other power strips, UPSes, oth
Streszczenie treści zawartej na stronie nr. 19
Belkin Power Console Belkin Connected Equipment Warranty To file a claim against the Belkin Connected Equipment Warranty, you must take the following steps: 1. You must have an original receipt with date of purchase. 2. Contact a Belkin Limited Customer Service Representative at 00 800 2 2 3 5 5460 within 15 days of the Occurrence. Be prepared to provide the following information: a. The part number of the Belkin Power Console. b. The equipment that was connected to the Belkin Powe
Streszczenie treści zawartej na stronie nr. 20
Belkin Ltd. Belkin SAS Belkin GmbH Express Business Park 130 rue de Silly Hanebergstrasse 2 Shipton Way, Rushden 92100 Boulogne-Billancourt, 80637 Munich NN10 6GL, United Kingdom France Germany +44 (0) 1933 35 2000 +33 (0) 1 41 03 14 40 +49 (0) 89 143405 0 +44 (0) 1933 31 2000 fax +33 (0) 1 41 31 01 72 fax +49 (0) 89 143405 100 fax Belkin Iberia Belkin Italy & Greece Belkin B.V. C/ Anabel Segura, 10 planta baja, Of. 2 Via Carducci, 7 Boeing Avenue 333 28108, Alcobendas, Madrid Milano 20123 1119