Streszczenie treści zawartej na stronie nr. 1
5H102-48 and 5H103-48
Fast Ethernet Installation Guide
FAST ENET
FAST ENET
5H103-48
5H102-48
RESET RESET
COM COM
CPU CPU
1X 12X
GROUP
GROUP
SELECT SELECT
G
G R
O
R
GROUP GROUP U GROUP GROUP
O
P
U
P
1
1
1X
11X
13X 24X
G
G R
R O
U
O
P
U
P
2
2
13X
23X
25X 36X
G
G
R
R O
O U
P
U
P
3
3
25X
35X
37X
48X
G
G
R
R
O
O U
U P
P
4
4
37X
47X
35861_00
9033586
Streszczenie treści zawartej na stronie nr. 2
Streszczenie treści zawartej na stronie nr. 3
ELECTRICAL HAZARD: Only qualified personnel should perform installation procedures. NOTICE Enterasys Networks and its licensors reserve the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL ENTERASYS NETWORKS
Streszczenie treści zawartej na stronie nr. 4
FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against ha
Streszczenie treści zawartej na stronie nr. 5
ENTERASYS NETWORKS, INC. PROGRAM LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between You, the end user, and Enterasys Networks, Inc. (“Enterasys”) that sets forth your rights and obligations with respect to the Enterasys software program (“Program”) in the package. The Program may be contained in firmware, chips or other media. UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME B
Streszczenie treści zawartej na stronie nr. 6
5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was developed solely at private expense; (ii) contains “restricted computer software” submitted with restricted rights in accordance with section 52.227-19 (a) through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Enterasys and/or its suppliers. For Department of Defense units, the Product is considered commercial computer s
Streszczenie treści zawartej na stronie nr. 7
DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Enterasys Networks, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. Jim Sims European Representative Address: Enterasys Networks Ltd. Nexus House, Newbury Business Park London Road, Newbury Berkshire RG14 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EC Directive 73/23/EEC EN 55022 EN 55024
Streszczenie treści zawartej na stronie nr. 8
vi
Streszczenie treści zawartej na stronie nr. 9
Contents Figures ............................................................................................................................................ix Tables.............................................................................................................................................. x ABOUT THIS GUIDE Using This Guide.............................................................................................................xi Structure of This Guide ....................
Streszczenie treści zawartej na stronie nr. 10
3 INSTALLATION 3.1 Unpacking the Module .................................................................................... 3-2 3.2 Installing the Module into the 5C105 Chassis ................................................. 3-3 3.3 Connecting to the Network..............................................................................3-5 3.3.1 Connecting UTP Cables to the 5H102-48.......................................3-5 3.3.2 Connecting UTP Cables to the 5H103-48............................
Streszczenie treści zawartej na stronie nr. 11
Figures Figure Page 1-1 The 5H102-48 and 5H103-48 Modules ........................................................................... 1-2 3-1 Installing a Module into the 5C105 Chassis .................................................................... 3-4 3-2 Connecting a Twisted Pair Segment to the 5H102-48 ....................................................3-6 3-3 Crossover Cable RJ45 Pinouts ....................................................................................... 3-7 3-4 Str
Streszczenie treści zawartej na stronie nr. 12
Tables Table Page 3-1 Contents of Module Carton...........................................................................................3-2 4-1 LANVIEW LEDs............................................................................................................ 4-3 4-2 Troubleshooting Checklist ............................................................................................ 4-5 A-1 COM Port Pin Assignments..........................................................................
Streszczenie treści zawartej na stronie nr. 13
About This Guide Welcome to the 5H102-48 and 5H103-48 Fast Ethernet Installation Guide. This guide describes the Fast Ethernet modules and provides information concerning network requirements, installation, and troubleshooting. For information about how to use Local Management to configure and manage the module, refer to the MATRIX E5 Series Modules (5H1xx and 5G1xx) Local Management User’s Guide. Important Notice Depending on the firmware version used in the module, some features described
Streszczenie treści zawartej na stronie nr. 14
Related Documents Chapter 2, Network Requirements, outlines the network requirements that must be met before installing the module. Chapter 3, Installation, provides instructions on how to install the module, and connect segments to the modules. Chapter 4, Troubleshooting, describes the function of the LANVIEW LEDs, which can help to quickly diagnose network/operational problems. Appendix A, Specifications, contains information on functionality and operating specifications, connector pinouts
Streszczenie treści zawartej na stronie nr. 15
Document Conventions DOCUMENT CONVENTIONS The guide uses the following conventions: NOTE: Calls the reader’s attention to any item of information that may be of special importance. TIP: Conveys helpful hints concerning procedures or actions. CAUTION: Contains information essential to avoid damage to the equipment. ELECTRICAL HAZARD: Warns against an action that could result in personal injury or death due to an electrical hazard. WARNING: Warns against an action that could result in personal i
Streszczenie treści zawartej na stronie nr. 16
Getting Help GETTING HELP For additional support related to the product or this document, contact Enterasys Networks using one of the following methods: World Wide Web http://www.enterasys.com/ Phone (603) 332-9400 Internet mail support@enterasys.com FTP ftp://ftp.enterasys.com Login anonymous Password your email address To send comments or suggestions concerning this document, contact the Technical Writing Department via the following email address: TechWriting@enterasys.com Make sure to incl
Streszczenie treści zawartej na stronie nr. 17
1 Introduction This chapter introduces the 5H102-48 and 5H103-48 Fast Ethernet modules. Important Notice Depending on the firmware version used in the module, some features described in this document may not be supported. Refer to the Release Notes shipped with the module to determine which features are supported. The 5H102-48 module (Figure 1-1) features 48 10BASE-T/100BASE-TX switched ports connected through 48 RJ45 front panel connectors. The 5H103-48 module (Figure 1-1) features 48 10BAS
Streszczenie treści zawartej na stronie nr. 18
Figure 1-1 The 5H102-48 and 5H103-48 Modules FAST ENET FAST ENET 5H102-48 5H103-48 RESET RESET COM COM COM Port CPU CPU 1X 12X System LED System LED GROUP GROUP SELECT SELECT Group Group G G R O R Select Select GROUP GROUP GROUP GROUP O U P U Switch Switch P 1 1 Port Port 1X Status Status 11X LEDs LEDs 13X 24X Group Group Select Select LEDs G LEDs G R R O O U U P P 2 2 13X 23X Network Network Ports Ports 25X 1-48 36X 1-48 G G R R O O U U P P 3 3 25X 35X 37X 48X G G R R O O U U P P 4 4 37X 47X 35
Streszczenie treści zawartej na stronie nr. 19
Connectivity 1.1 CONNECTIVITY The module connects to Ethernet networks or workstations through the front panel connectors. The ports support Unshielded Twisted Pair (UTP) cables with an impedance between 85 and 111 ohms at lengths up to 100 meters. The ports are IEEE 802.3 10BASE-T and 100BASE-TX compliant. 1.2 HALF-DUPLEX/FULL-DUPLEX AUTO-NEGOTIATION The fixed front panel ports on the module have the ability to auto-negotiate the ports’ mode of operation (half-duplex or full-duplex) between
Streszczenie treści zawartej na stronie nr. 20
Port/VLAN Redirect Function 1.5 PORT/VLAN REDIRECT FUNCTION The port redirect function, also referred to as “Port Mirroring,” is a troubleshooting tool used to map traffic from a single source port to a single destination port within the module. This feature allows frames, including those with errors, to be copied and sent to an analyzer or RMON probe. The analyzer or RMON probe will see the data as if it were directly connected to the LAN segment of the source port. The VLAN redirect functi