Streszczenie treści zawartej na stronie nr. 1
®
HS5000/HS5001
High Security/Harsh Environment
Enclosure
Installation/Operation Manual
C489M-A (1/96)
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827
Streszczenie treści zawartej na stronie nr. 2
TABLE OF CONTENTS Section Page 1.0 WARNINGS ........................................................................................................................................1 2.0 SCOPE ...............................................................................................................................................2 3.0 DESCRIPTION ...................................................................................................................................2 3.1 POWER REQU
Streszczenie treści zawartej na stronie nr. 3
LIST OF ILLUSTRATIONS Figure Page 1 HS5000 Wiper/Washer/Heater Connections ...................................................................................3 2 Wiring Diagram for HS5001 Heaters ...............................................................................................3 3 HS5000/HS5001 Exploded Assembly Drawing...............................................................................5 4 HS5000/HS5001 Dimension Drawing ...................................................
Streszczenie treści zawartej na stronie nr. 4
(This page intentionally left blank.) iv Pelco Manual C489M-A (1/96)
Streszczenie treści zawartej na stronie nr. 5
INSTALLATION/OPERATION MANUAL HS5000/HS5001 HIGH SECURITY/ HARSH ENVIRONMENT ENCLOSURE 1.0 WARNINGS Prior to installation and use of this product, the following 4. After replacement/repair of this unit’s electrical WARNINGS should be observed. components, conduct a resistance measurement between line and exposed parts to verify the exposed 1. Installation and servicing should only be done by parts have not been connected to line circuitry. Qualified Service Personnel and conform to all Local co
Streszczenie treści zawartej na stronie nr. 6
2.0 SCOPE 3.1 POWER REQUIREMENTS HS5000 The information contained within this manual covers Heater: 20 watts the HS5000/HS5001 High Security/Harsh Environment Wiper: 3 watts Camera Enclosure. Washer: 30 watts Installation should be in accordance with all applicable HS5001 local and national electric codes, utilizing approved With heater unit installed: materials only. 120/230/24 VAC heater ----------- 40 watts 12VDC ------------------------------20 watts 3.0 DESCRIPTION (available if used wit
Streszczenie treści zawartej na stronie nr. 7
4.0 INSTALLATION 4.2 HS5001 HEATER CONNECTION Before installing the HS5000/HS5001, make certain that Heater connections for all models used with the HS5001 the mounting surface is able to support the full load of are wired the same. Refer to Figure 2 for proper wiring the enclosure plus all other equipment such as camera, connections. lens, etc. The heaters are all thermostatically controlled. They NOTE: The fasteners required to secure the are activated ON at 40°F (4.44°C) and are activated e
Streszczenie treści zawartej na stronie nr. 8
4.5 ENCLOSURE MOUNTING 4.3 CAMERA/LENS INSTALLATION Secure the enclosure to the mounting surface with suit- To install the camera/lens, perform the following steps: able fasteners (not supplied). 1. Remove the lid by removing the eight (8) 10-32 x 5.0 CARE AND MAINTENANCE 1/2" socket head cap screws. Regularly scheduled maintenance will help prolong the 2. Remove two (2) 6-32 x 3/8" socket head cap operational life and appearance of the equipment. screws from the rear of the PC board. This wi
Streszczenie treści zawartej na stronie nr. 9
6.0 EXPLODED ASSEMBLY DRAWING Figure 3. HS5000/HS5001 Exploded Assembly Drawing Pelco Manual C489M-A (1/96) 5
Streszczenie treści zawartej na stronie nr. 10
7.0 MECHANICAL PARTS LIST The following parts list corresponds to the exploded assembly drawing in Figure 3. Item Quantity Description Part Number 1 1 Gear, shaft, drilled HS50004055COMP 2 1 Heater blanket, 2" x 2" 24V, 40 W (not shown) EHHK10087 3 1 Bolt, 1/4" x 1-1/2" (not shown) HS500010000 4 1 Stone guard (not shown) HS500010005 5 1 Base plate HS50004001COMP 6 1 Side plate, right HS50004002COMP 7 1 Side plate, left HS50004003COMP 8 1 Window frame plate HS50004004COMP 9 1 Plate, lid HS500040
Streszczenie treści zawartej na stronie nr. 11
8.0 SPECIFICATIONS Input Voltage: HS5000 12 VDC HS5001 120/230/24VAC; optional 12VDC input if using 24VAC heater unit. Cable Entry: Two (2) .75" (1.91 cm) conduit holes Window: .5" (12.7 mm) thick, impact and abrasion resistant Lexan Camera Mounting: Removable camera sled with isolation mounts (4) Maximum Camera/Lens: Length 5.00" (12.7 cm) Width: 2.00" (5.08 cm) Height: 2.50" (6.35 cm) Construction: Aluminum, 6061-T6 3/8" thick plate Mechanical Fastening Finish: Polyester powder coat Dimension
Streszczenie treści zawartej na stronie nr. 12
9.0 WARRANTY AND RETURN INFORMATION WARRANTY RETURNS Pelco will repair or replace, without charge, any merchandise proved In order to expedite parts returned to the factory for repair or credit, please defective in material or workmanship for a period of one year after the date call the factory at (800) 289-9100 or (559) 292-1981 to obtain an of shipment. authorization number (CA number if returned for credit, and RA number Exceptions to this warranty are as noted below: if returned for repair).