RECOMMENDATIONS FOR PROPER PROTECTION The following recommendations for the location of fire and burglary detection devices help provide proper coverage for the protected premises. Recommendations for Smoke and Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below. Early-warning fire detection is best achieved by the installation of fire detection
Streszczenie treści zawartej na stronie nr. 3
Table of Contents •••••••••••••••••••••••••••••••••••••••••••••••••• SECTION 1. Introduction............................................................................................................................1–1 Description ........................................................................................................................................................1-1 Features........................................................................................................
Streszczenie treści zawartej na stronie nr. 4
SECTION 11. Final Power-Up ....................................................................................................................11–1 Earth Ground Connections ............................................................................................................................11-1 Wiring the AC Transformer ...........................................................................................................................11-1 AC Power-Up ................................
Streszczenie treści zawartej na stronie nr. 5
SECT ION 1 Introduction •••••••••••••••••••••••••••••••••••••••••••••••••• In This Section Description Features •••••••••••••••••••••••••••••••••••••••••••••••••• Description The VISTA–10SE is a control that supports up to 22 hardwired and wireless zones, plus remote keypads. Features Basic Hardwired Zones Provides 6 basic hardwired zones having the following characteristics: • Zones 1-6 response time is 300–500 milliseconds. • Zone 3 programmable fast response time is 10–15 milliseconds. •
Streszczenie treści zawartej na stronie nr. 6
VISTA-10SE Installation and Setup Guide Security Codes One Master code for entire system (User 2). Installer code is User 1. 4 secondary user codes (Users 3–6). One duress code (User 8). Duress Code: An emergency code that, when used to disarm or arm the system, will send a . silent duress message to the central station Keypad Panic Keys • Up to 3 programmable panic key functions are provided. • Designated as Zones 7, 95, 96. • Activated by wired and wireless keypads. • Reported separate
Streszczenie treści zawartej na stronie nr. 7
Section 1 - Introduction Alarm Output • Provides a 12VDC, 2 AMP output that can drive the compatible sounders listed in the EXTERNAL SOUNDERS section (assumes a fully charged battery is connected). • Steady output for burglary/panic, or temporal pulse sounding output for fire notification, as required by UL. • Uses current-limiting circuitry for protection. Auxiliary Power Output • Provides 12VDC, 500mA maximum. Uses current limiting circuitry for protection. • This output interrupts for smoke d
Streszczenie treści zawartej na stronie nr. 8
VISTA-10SE Installation and Setup Guide 1-4
Streszczenie treści zawartej na stronie nr. 9
SECT ION 2 Installing the Control •••••••••••••••••••••••••••••••••••••••••••••••••• In This Section Mounting the Control and RF Receiver Circuit Mounting the Cabinet Board in the Cabinet Installing the Lock Standard Phone Line Connections Mounting the Control's Circuit Board Alone in the Cabinet •••••••••••••••••••••••••••••••••••••••••••••••••• Mounting the Cabinet Mount the control cabinet to a sturdy wall using fasteners or anchors (not supplied), in a clean, dry area that is not r
Streszczenie treści zawartej na stronie nr. 10
VISTA-10SE Installation and Setup Guide Mounting the Control's Circuit Board Alone in the Cabinet To mount the circuit board alone in the cabinet, follow these steps: 1. Hang two mounting clips* (provided) on the raised cabinet tabs (see Detail B in Figure 2 below). 2. Insert the top of the circuit board between the rows of slots at the top of the cabinet as shown in Detail A. 3. Position the base of the board onto the mounting clips and secure both to the cabinet with the supplied screws (see D
Streszczenie treści zawartej na stronie nr. 11
Section 2 - Installing the Control HOLES FOR ANTENNAS CABINET AND GROUNDING LUGS CIRCUIT BOARD BOARD RECEIVER CIRCUIT BOARD SUPPORTING DETAIL A (See Detail D) SLOTS SIDE VIEW + + OF BOARD SUPPORTING SLOTS MOUNTING CLIP CONTROL CIRCUIT BOARD MOUNTING CLIP DETAIL B SIDE VIEW SCREW OF MOUNTING (2) CLIP ANTENNA (2) GROUNDING LUG (2) CABINET DETAIL C RCVR BRD SIDE VIEW OF MOUNTING + + CLIP ANTENNA MOUNT (2 PLACES) DETAIL D ANTENNA AND GROUNDING LUG INSTALLATION V10SE-004-V0 Figure 3. Mounting the PC
Streszczenie treści zawartej na stronie nr. 12
VISTA-10SE Installation and Setup Guide INCOMING TELECOM LINE HANDSET 17 18 19 20 21 TERMINALS ON CONTROL EARTH GROUND INCOMING TELECOM LINE PLUG TIP RJ31X JACK PREMISES RING PHONES DIRECT CONNECT CORD V10SE-024-V0 Figure 4. Standard Telephone Line Connections 2-4 BROWN (TIP) GREY (RING) GREEN (TIP) RED (RING) GROUND TIP RING
Streszczenie treści zawartej na stronie nr. 13
SECT ION 3 Remote Keypads •••••••••••••••••••••••••••••••••••••••••••••••••• In This Section Keypads That May Be Used Supplementary Power for Additional Keypads Wiring to the Keypads Preliminary Checkout Procedure Mounting the Keypads •••••••••••••••••••••••••••••••••••••••••••••••••• This section lists the wired keypads that may be used and provides instructions for wiring and mounting the keypads. A preliminary checkout procedure is also provided to ensure that the connected keypads
Streszczenie treści zawartej na stronie nr. 14
VISTA-10SE Installation and Setup Guide Wiring Run Chart for Devices* Drawing Aux Power From the Control (12V+ & 12V–) TOTAL CURRENT DRAWN BY ALL DEVICES CONNECTED TO A SINGLE WIRE RUN Wire Size 50mA or less 100mA 300mA 500mA #22 500 ft (152m) 250 ft (76m) 80 ft (24m) 50 ft (15m) #20 750 ft (228.6m) 380 ft (116m) 130 ft (39.6m) 80 ft (24m) #18 1300 ft (396m) 650 ft (198m) 220 ft (67m) 130 ft (39.6m) #16 1500 ft (457m) 1000 ft (305m) 330 ft (100.5m) 200 ft (70m) * Includes keypads, RF receivers,
Streszczenie treści zawartej na stronie nr. 15
Section 3 - Installing Remote Keypads Keypads powered from supplies that do not have a backup battery will not function when AC power is lost. Therefore, be sure to power at least one keypad from the Control's auxiliary power output. Connect the additional keypads as shown in Figure 6, using the keypad wire colors shown. Be sure to observe the current ratings for the power supply used. Make connections directly to the screw terminals as shown in Figure 6. Make no connection to the keypad blue wi
Streszczenie treści zawartej na stronie nr. 16
VISTA-10SE Installation and Setup Guide If the “Ready” message is not displayed on any of the keypads in the system, or a “Not Ready” message is displayed, check the keypad wiring connections, and make sure each of the 6 basic hardwired zones has a 1000 ohm resistor connected across its terminals. Do not remove the EOL resistors until you are ready to make connections to the hardwired zones, to allow for testing later in the manual. If an OC or OPEN CIRCUIT display is present on the keypad, data
Streszczenie treści zawartej na stronie nr. 17
SECT ION 4 Basic Hardwired Zones 1–6 •••••••••••••••••••••••••••••••••••••••••••••••••• In This Section Installing the Hardwired Zones Programming Hardwired Zones •••••••••••••••••••••••••••••••••••••••••••••••••• Installing the Hardwired Zones Common Characteristics for Zones 1–6 • Response time from 300 - 500 milliseconds (400 milliseconds nominal). • Zone 3 can be programmed (in field ✱ 52) for normally-closed sensor fast response (10mSec max) to an open (suitable for vibration type conta
Streszczenie treści zawartej na stronie nr. 18
VISTA-10SE Installation and Setup Guide 3. To meet NFPA 72 requirements, you must use a supervisory module to supervise power (e.g., System Sensor No. A77-716B Relay module). + 5 AUX PWR OUTPUT _ BLK + RED TERMINALS _ 4 4-WIRE SMOKE EOL OR COMBUSTION POWER DETECTORS SUPERVISION + + RELAY MODULE _ _ A77-716B VIOLET 1000 OHMS TO HI SIDE OF + EOLR HEAT HEAT ZONE 5 DETECTOR DETECTOR _ V10SE-010-V0 TO LO SIDE Figure 7. 4-wire Smoke Detector Connections (Zone 5) Compatible System Sensor 4-Wire Smoke/
Streszczenie treści zawartej na stronie nr. 19
SECT ION 5 Wireless Expansion (5800 System) •••••••••••••••••••••••••••••••••••••••••••••••••• In This Section About Wireless Expansion About Jam Detection and Reporting Installing the 5881/5882 Receiver 5800 Series Transmitters Installing the 5800TM Module Installing 5800 Series Transmitters •••••••••••••••••••••••••••••••••••••••••••••••••• About Wireless Expansion The VISTA-10SE supports up to 16 wireless zones that may be used exclusively or in addition to hardwired zones 1 throu
Streszczenie treści zawartej na stronie nr. 20
VISTA-10SE Installation and Setup Guide Installing the 5881/5882 Receiver RF System Installation Advisories Follow the guidelines below when installing the RF receiver. (Disregard if the receiver is mounted in the control cabinet.) • Place the RF receiver in a high, centrally located area for best reception. • Do not locate the receiver or transmitters on or near metal objects. This decreases range and/or block transmissions. • Do not locate the receiver in an area of high RF interference (revea