Streszczenie treści zawartej na stronie nr. 1
45137
Wireless Alarm System
™
Silent Alert
User’s Manual
Choice
Choice
ALERT
ALERT™
™
Control all Sensors
& accessories from
one location
Streszczenie treści zawartej na stronie nr. 2
Table of Contents Important Safeguards 4 Introduction 4 Adding a Silent Alert to the system 5-6 Testing the Silent Alert or your system 6 Installation 7 Low battery indicator 9 Battery warnings 9 FCC Warning 8
Streszczenie treści zawartej na stronie nr. 3
Before connecting or operating the Silent Alert, please read these instructions carefully and save this manual for future reference. Congratulations ™ The GE Choice Alert Wireless Alarm System is one of the most affordable and expandable wireless alarm systems available. You’ll discover the system offers many features typically found in custom installed Alarm systems. The Choice Alert system is reliable and easy-to-use. With Choice Alert you can select from a line of Sensors and Acces
Streszczenie treści zawartej na stronie nr. 4
Important safeguards PreCautions 1. Do not attempt to disassemble the Silent Alert, unless described in the user’s manual. There are no user serviceable parts. . Handle with Care – Avoid striking or shaking. Improper use or storage could damage the Silent Alert. Modifying or tampering the device or its internal components can cause a malfunction and void the Silent Alert’s warranty. . If you feel the Silent Alert or any part of the Choice Alert system is not operating correctly or as
Streszczenie treści zawartej na stronie nr. 5
The Silent Alert will only activate once an alarm is actually sounded. It will not activate during the entry and exit delay times. It cannot be turned-off unless it receives a disarm code from the Control Center it is linked with, or the batteries have been removed. Once activated it will continue to blink for several days. It cannot be disarmed even if the Control Center is unplugged or destroyed. Parts Check List Identify all the parts before proceeding. The Silent Alert is designed
Streszczenie treści zawartej na stronie nr. 6
been triggered. You can add any number of Silent Alert LED indicators to the Choice Alert System. To add a Silent Alert to the system, you will need to link it with the Control Center. Adding a Silent Alert™ In order to link the Silent Alert to the Crontrol Center, you will need to have the Silent Alert and Control Center near each other. Step 1 - Open the Silent Alert by gently inserting a small blade screwdriver into the tab slot on one end and gently pry upwards. This action rele
Streszczenie treści zawartej na stronie nr. 7
three seconds. Step 4 - Release all buttons. The Control Center will sound two beeps and flash the green power indicator, this Input DC 12V indicates a test signal was sent to the Silent - + Mute Alert. When the Silent Alert receives the test Learn Signal, the LED indicator will stop flashing, Alert indicating it has been linked with your Chime Off Control Center. Reattach the Silent Alert to the base. Anytime the alarm is triggered (in Armed HOME or AWAY), and the siren sounds, the C
Streszczenie treści zawartej na stronie nr. 8
If the mounting surface is rough or porous, you will need to use the rubber gromments and screws (included). Secure the plate to the desired location with the screws. Smooth surface Porus uneven surface Test the Silent Alert Step 1 - After the Silent Alert has been successfully linked with the Control Center, press and hold the Mute button on the Control Center for three seconds. This action sends a test signal. Step 2 - When the Silent Alert receives the test signal from the C
Streszczenie treści zawartej na stronie nr. 9
Step 3 - While pressing the Learn button, re-install the batteries. The LEDs will flash rapidly and then stop. This indicates the Silent Alert has been removed from the system. Step 4 - Release all buttons Low Battery Indicator When the voltage level of batteries reach low levels, one LED will begin to flash once every 5 seconds. This indicates that the batteries need to be replaced. Model # Description Battery Type Battery Life* 45129 Control Center (4) “AAA” 24 months 4513
Streszczenie treści zawartej na stronie nr. 10
FCC Warning Any unauthorized changes or modifications to the equipment would void the user’s warranty and may conflict with both state and federal laws. The Choice Alert system complies with part 15 of the FCC rules. Operation is subject to the following conditions: 1) The Choice Alert system may not cause harmful interference. ) The Choice Alert system may accept any interference received including interference that may cause undesired operation. NOTE: This equipment has been tested
Streszczenie treści zawartej na stronie nr. 11
WARNING Limitations of Alarm Products This product should be tested periodically to make sure it is working properly. The product, if used properly, may reduce the risk of burglary, robbery, or other adverse events. However, JASCO is not an insurer, this product is neither insurance nor a guarantee that such an event will be prevented, and users should protect themselves with proper insurance. JASCO makes no representation that this product cannot be compromised or circumvented, that it w
Streszczenie treści zawartej na stronie nr. 12
is a trademark of the General Electric Company and is used under license to Jasco Products Company LLC, 10 E. Memorial Road, Oklahoma City, OK 73114. This Jasco product comes with a 45137-1 1 year limited warranty. Visit 01/09/08 www.jascoproducts.com for details.