GV2 Series Control Panels
Owner's Manual
EN Supplement
Streszczenie treści zawartej na stronie nr. 2
GV2 Series Control Panels | Owner's Manual Supplement System Requirements Minimum system requirements for Classification in accordance with ANSI/SIA CP-01-2000: • UL Listed and Classified control unit Model D9412GV2, D7412GV2, or D7212GV2 • UL Listed and Classified keypad Model D1256, D1257, D1260, D1255, D1255R, or D1255 RW • UL Listed Local Bell The minimum firmware requirements for SIA CP-01 compliance are: Control Panel Firmware Version D9412GV2 7.05 or later D7412GV
Streszczenie treści zawartej na stronie nr. 3
GV2 Series Control Panels | Owner's Manual Supplement Contents 1.0 Introduction....................................................................... 5 2.0 General Commands........................................................... 5 2.1 Two-Man Rule............................................................................ 5 2.1.1 Description................................................................................. 5 2.1.2 Using the Two-Man Rule ...............................
Streszczenie treści zawartej na stronie nr. 4
GV2 Series Control Panels | Owner's Manual Supplement 2.10.1 Description ............................................................................... 18 2.10.2 Using DEL USER ? ................................................................. 18 2.11 Add/Change User - [COMMAND 56] ....................................... 19 2.11.1 Description ............................................................................... 19 2.11.2 Using Add User ? .......................................
Streszczenie treści zawartej na stronie nr. 5
GV2 Series Control Panels | Owner's Manual Supplement 1.0 Introduction This document supplements the Security System Owner’s Manual (P/N: 71-06633-000) with the features for the GV2 Series. The instructions for the commands listed in this document replace those commands in the Security System Owner’s Manual. Refer to the Owner’s Manual for the operation of your new security system and its other basic features. Place this supplement inside the Security System Owner’s Manual. 2
Streszczenie treści zawartej na stronie nr. 6
GV2 Series Control Panels | Owner's Manual Supplement 2.2 Early Ambush 2.2.1 Description Early Ambush adds an extra step to the disarming process by requiring the entry of an additional passcode to confirm that the area is secure. The second passcode can be same as the first or different, depending upon the configuration. The first entry disarms the area and the second entry stops an automatic timer from sending a duress event. I have this feature. I do not have this feature. 2
Streszczenie treści zawartej na stronie nr. 7
GV2 Series Control Panels | Owner's Manual Supplement 2.3 Easy Exit Control 2.3.1 Description The GV2 Series control panels change from one armed state to another armed state without disarming. The Easy Exit Control feature decreases the number of keystrokes and simplifies system operation. This feature is available by default and is always on. 2.3.2 Using Easy Exit Control Switching armed states from Master to Perimeter: 1. Ensure that the keypad shows idle master armed text. 2. Pr
Streszczenie treści zawartej na stronie nr. 8
GV2 Series Control Panels | Owner's Manual Supplement 2.4 Passcode Follows Scope 2.4.1 Description The Passcode Follows Scope feature is an optional arming and disarming restriction that can be enabled on keypads with access to multiple areas. When this feature is set to No, the keypad restricts Passcode Arming and Passcode Disarming to the home area of the keypad. When set to Yes, this feature allows users to arm or disarm all the areas to which they and the keypad have access. This
Streszczenie treści zawartej na stronie nr. 9
GV2 Series Control Panels | Owner's Manual Supplement 2.5 Passcode-Controlled Menu 2.5.1 Description When enabled, the system prompts users to enter a passcode before viewing the keypad menu. The system shows the user the menu options allowed according to their authority level, thereby providing users only pertinent commands and functions. I have this feature. I do not have this feature. 2.5.2 Using Passcode Controlled Menus On a D1255 Keypad with the Passcode Controlled Menu e
Streszczenie treści zawartej na stronie nr. 10
GV2 Series Control Panels | Owner's Manual Supplement 2.6 Walk Tests 2.6.1 Description The D9412GV2, D7412GV2, and D7212GV2 have three Walk Test menus that allow the user to test various points that are within the scope of the keypad without sending a report to the central station. Test each smoke detector according to the manufacturer’s instructions. Table 1: Walk Test Menu Access Test Type Command Menu Function Name Point Types Sequence Tested WALK TEST ? Walk [COMMAND]
Streszczenie treści zawartej na stronie nr. 11
GV2 Series Control Panels | Owner's Manual Supplement 4. Press the [ENT] key to activate the selected walk test function. The keypad shows the number of testable points within the scope of the keypad: ### PTS TO TEST 5. Press the [NEXT] key to see VIEW UNTESTED? 6. Press the [ENT] key to view the untested points. The keypad shows the total number of untested points within the keypad scope: ### PTS UNTESTED. 7. Press the [NEXT] key to view the first point’s name. 8. Press the [ENT] ke
Streszczenie treści zawartej na stronie nr. 12
GV2 Series Control Panels | Owner's Manual Supplement 5. Press the [View untested Pts >] soft key to see ### PTS UNTESTED. 6. Press the [Next Pt >] soft key to view the first or next untested point: [Point Text] Area #, Pt # [Point State] HW Next PT> The point state can be NORMAL, OPEN, SHORT, or MISSING. 7. Activate the point’s sensor and observe the state change. 8. Repeat Steps 5 through 7 until all points are tested
Streszczenie treści zawartej na stronie nr. 13
GV2 Series Control Panels | Owner's Manual Supplement 2.8 Access Level Control 2.8.1 Description Use this function to manually enable or disable access authority levels assigned to users. This function can be used to disable a user’s access level temporarily instead of deleting and adding the user. I have this feature. I do not have this feature. 2.8.2 Using ACCESS LEVEL CTL? On a D1255 Keypad 1. Activate the door’s custom functions. Refer to Section 2.7.2 Using Door Activate
Streszczenie treści zawartej na stronie nr. 14
GV2 Series Control Panels | Owner's Manual Supplement 4. Press the [Change Level ? >] soft key. ACCESS LEVEL CTL appears, indicating that you are affecting the authority levels of cards or tokens and not passcodes. 5. ENTER LEVEL: appears. Enter the access authority level number and press [ENTER]. 6. If the access level is currently disabled, LEVEL # ENABLE? appears. If the access level is currently enabled, LEVEL # DISABLE? appears. Press [ENTER] to accept the choice. 7. Repeat Ste
Streszczenie treści zawartej na stronie nr. 15
GV2 Series Control Panels | Owner's Manual Supplement 7. The first sub-function that appears is CYCLE DOOR?. You can cycle through the three sub-functions by pressing [PREV] and [NEXT]. On a D1260 Keypad 1. Ensure that the display shows idle disarmed text. 2. Press the [COMMAND] key. The display shows SYSTEM COMMAND. 3. Press [4] and [6]. You can use the function list in place of steps 2 and 3 to start this function. 1. Press the [Menu>] soft key to enter the function list.
Streszczenie treści zawartej na stronie nr. 16
GV2 Series Control Panels | Owner's Manual Supplement 2. Enter the number of the door to cycle then press [ENT]. This door cycles and the display changes to reflect the new status of the doors. For example, to cycle Door 3, at the CYCLE DOOR 1 2 3 4 5 6 7 8 prompt, press [3], then press [ENT]. The display shows CYCLE DOOR 1 2 C 4 5 6 7 8. This indicates that all doors are in a normal state, except for Door 3, which is cycled. 3. Press [ESC] to leave this sub-function, or enter anothe
Streszczenie treści zawartej na stronie nr. 17
GV2 Series Control Panels | Owner's Manual Supplement 3. Enter the number of the door to secure then press [ENT]. This door secures, and the display changes to reflect the new status of the doors. For example, to secure Door 5, press [5], then press [ENT] at the following prompt: SECURE DOOR 1 2 3 4 5 6 7 8 The display shows SECURE DOOR 1 2 3 4 X 6 7 8. This indicates that all doors are in a normal state, except for Door 5, which is secured. 4. Press [ESC] to leave this sub-function
Streszczenie treści zawartej na stronie nr. 18
GV2 Series Control Panels | Owner's Manual Supplement 2.10 Delete User [COMMAND 53] 2.10.1 Description Use this function to delete a personal passcode from your system without assistance from your security company. You must know the user number for the passcode you want to delete. I have this feature. I do not have this feature. 2.10.2 Using DEL USER ? 1. Ensure that the display shows idle disarmed text. 2. Press the [COMMAND] key. The display shows SYSTEM COMMAND. 3. Press [5
Streszczenie treści zawartej na stronie nr. 19
GV2 Series Control Panels | Owner's Manual Supplement 2.11 Add/Change User - [COMMAND 56] 2.11.1 Description Use this function to add or change a passcode or card without assistance from your security company. Before adding or changing a passcode or card, you must know which user numbers are available, the authority level you want to assign to the new user, and the areas in which the passcode or card are valid. I have this feature. I do not have this feature. 2.11.2 Using Add U
Streszczenie treści zawartej na stronie nr. 20
GV2 Series Control Panels | Owner's Manual Supplement For systems with access control, the following prompts are available: ADD CARD?, CHANGE CARD?, and SUB USER ID?. Refer to Systems With Access Control on page 20 for details. The system does not accept a passcode that is within two digits of an existing passcode. This is to avoid conflicts with duress passcodes. For example, if passcode 123 is already programmed in the system, the system does not accept 121, 122, 124, or 1