TABLE OF CONTENTS 1. SPECIFICATIONS ...................................................................................... 1 2. PANEL FUNCTIONS ................................................................................... 2 3. OPERATING INSTRUCTION..................................................................... 4 3.1. Normal Operation................................................................................... 5 3.2. Using the Mechanical Adaptor (Option RM1502)..............
Streszczenie treści zawartej na stronie nr. 4
Streszczenie treści zawartej na stronie nr. 5
1. SPECIFICATIONS Speed (Non-contact): Range Resolution Accuracy RPM 10.00 - 99999 0.01/0.1/1 0.04% ±2 dgts rps(Hz) 0.200 - 2000.0 0.001/0.01/0.1 0.04% ±2 dgts Speed (Contact) Range Resolution Accuracy RPM / (/ 20.00 - 29999 0.01/0.1/1 0.04% ±2 dgts symoblizes "Contact" m/min 2.000 - 2999.9 0.001/0.01/0.1 0.04% ±2 dgts ft/min 6.00 - 10000 0.01/0.1/1 0.04% ±2 dgts yard/min 4.00 - 3000 0.01/0.1/1 0.04% ±2 dgts Event Counter: Range Max. Input Frequency 0 - 99999 10KHz. with 5% duty cycle External T
Streszczenie treści zawartej na stronie nr. 6
2. PANEL FUNCTIONS 2 2
Streszczenie treści zawartej na stronie nr. 7
2.1. Reflecting tape Attach a reflecting tape to the surface of the unit to be measured 2.2. Reflecting signal light beam It is recommenced that the reflecting surface is perpendicular to the emitting/receiving unit for best measurement. 2.3. Emitting/Receiving Unit The red light emits from the left side of the tachometer. And a receiving sensor is installed in the right side to receive light signal from the reflecting surface. 2.4. LCD The lower row of the LCD is a 5 digit number to display RP
Streszczenie treści zawartej na stronie nr. 8
2.10. Start Measurement Symbol 2.11. Hours:Minutes Clock 4 4
Streszczenie treści zawartej na stronie nr. 9
3. OPERATING INSTRUCTION 5 5
Streszczenie treści zawartej na stronie nr. 10
3.1. Normal Operation a. Install four 1.5V AA size batteries. b. Cut off a piece of reflective tape of size 1.0 cm x 1.4 cm (optimal size) c. Wipe off oil or stains from the surface where reflective tape will be adhered. d. Stick the self-adhesive reflective tape on the object whose rotational speed is to be measured. The reflective tape should be attached as close to the outer edge of the object to be measured as possible. e. Press the START button to turn on tachometer. f. Point the photoelec
Streszczenie treści zawartej na stronie nr. 11
3.2. Using the Mechanical Adaptor (Option RM1502) a. Select proper rubber head. b. Attach the mechanical adaptor to the unit.and fasten the screw. c. Press the unit button (left button) to select RPM / ( instead of RPM only). The auxiliary LED will be turned on while the main LED will be turned off. d. Press against the shaft of the object to be measured. e. Do not press against the shaft too hard to avoid hazard. WARNING: Do not exceed the speed limit of 29999 rpm when using mechanical adaptor
Streszczenie treści zawartej na stronie nr. 12
3.3. Measurement of Surface Speed(m/min, ft/min, or yd/min) a. Attach the mechanical adaptor (option RM-1502) to the unit. b. Press the unit button to select desired unit. The auxiliary LED will be turned on while the main LED will be turned off. c. Slightly touch against the surface to be measured. 8 8
Streszczenie treści zawartej na stronie nr. 13
3.4. Use as an Event Counter with External Light Source a. Press the unit button several times to select the unit of "No. O" (counts). The "O" symbol is used to instruct users that external light source is required. b. When the symbol "No. O" appears, the tachometer reset the upper clock to 00:00 and start counting the pulses it detects. (Auto-power- off is automatically disabled) c. To stop counting, press the START button once. d. To reset counts to zero, press the function(right) button. 3.5.
Streszczenie treści zawartej na stronie nr. 14
3.6. External Signal(TTL) Input (RM1501) Instead of receiving signal from light source, users can input external TTL signal (High: > 4.5V, Low: 0V) through pin 8 of RS232C connector with pin 5 as signal ground. NOTE: It is strongly recommended that the emiting/receiving unit be covered to avoid undesired light signal coming in. 3.7. Digital Pulse Signal Output (RM1501) Users can output digital pulse signal through pin 8 of RS232C connector with pin 5 as signal ground to oscilloscope.
Streszczenie treści zawartej na stronie nr. 15
3.8. Measuring Slow Rotating Objects If the rotating speed of the object which you are measuring is very slow, it is recommended that you use a tripod to hold the tachometer in place and use multiple pieces of tape for more accurate result. If multiple pieces of tape are used, each piece of tape should be located at a equal distance to each other on the object. Any number of pieces of tape are acceptable. But you need to divide the reading by the number of pieces to obtain the correct result. C
Streszczenie treści zawartej na stronie nr. 16
seconds, and the max/min/ave symbols will disappear in LCD. 3.10. Turning On/Off Tachometer Press any button will turn on the power of tachometer. To turn off the power of tachometer, press and hold the START button until word "OFF" is displayed in LCD. Then release the START button. 3.11. Disable Auto-Power-Off Function If tachometer is in auto-power-off mode, only the minutes will be displayed. And tachometer will be turned off in 30 minutes. To disable the aut
Streszczenie treści zawartej na stronie nr. 17
3.12. REPLACING THE BATTERIES a. When the symbol (low battery) appears in the LCD, it is time to replace the batteries. b. Remove the screw of the battery cover and remove the battery cover. c Replace the old batteries with 4 new batteries. Do not mix different type of batteries together. d. Replace the battery cover and fasten the screw. 13 13
Streszczenie treści zawartej na stronie nr. 18
4. Protocol of RS-232C Serial Interface (RM-1501) Ten bytes are sent out through RS-232C connector to PC. The definitions of each byte are as followings: Byte 1: Leading byte 0x0D Byte 2: Decimal point of LCD display bit0: dp1 (0000.0), if 1 bit1: dp2 (000.00), if 1 bit2: dp3 (00.000), if 1 Byte 3: Flags for current status bit0: low battery, if 1 bit1: Max. value overflow, if 1 bit2: Counter overflow, if 1 bit3: Auto-power-off disable, if 1 bit4: Min. value overflow, if 1 bit5: Ave. value overf
Streszczenie treści zawartej na stronie nr. 19
TM 5. Installation of Window Application Software (RM-1501) 5.1. For Windows 3.1 TM TM A. Start Microsoft Windows B. Insert disk in drive A (or B) C. From Program Manager, select File menu and choose Run D. Type a:\setup (or b:\setup) and press Enter key 5.2. For Windows 95 TM A. Start Windows 95 B. Insert disk in drive A (or B) C. Press START button, then select Run D. Type in a:\setup (or b:\setup) and press Enter key 15 15
Streszczenie treści zawartej na stronie nr. 20
TM 6. Description of Windows Application Program (RM-1501) Main Window: When the program is executed, the program automatically search for connected tachometer or available serial port. If no serial port is available, then a message of "No communication port" will be displayed, and the program exits . Once communication port is setup, a main window will be displayed on the screen as below: Sample: Sampling time. Option: Display option of anemometer. Normal, MAX, MIN, AVE Unit: rpm, m/min, ft/mi