Streszczenie treści zawartej na stronie nr. 1
Built-In LP Side Burner
BUILT-IN LP SIDE BURNER INSTALLATION/OWNER'S GUIDE
Installation/Owner’s Guide
GUÍA DEL PROPIETARIO DEL ASADOR DE GAS LICUADO DE PROPANO - PG 21
GUIDE DE L’UTILISATEUR DU GRILL À GAZ PL - PG 38
#56069
THIS APPLIANCE MAY BE PURCHASED SEPERATELY FOR YOUR WEBER BUILT-IN BARBECUE GRILL.
YOU MUST READ THIS OWNER’S GUIDE WARNING: Follow all leak-check
BEFORE OPERATING YOUR SIDE BURNER procedures carefully in this manual prior
to operation. Do this even if the appliances
Streszczenie treści zawartej na stronie nr. 2
2 DANGERS & WARNINGS DANGER Failure to follow the Dangers, Warnings and Cautions contained in this Owner’s Manual may result in serious bodily injury or death, or in a fire or an explosion causing damage to property. WARNINGS Do not store a spare or disconnected liquid propane cylinder under or near the barbecue and Side Burner. Improper assembly may be dangerous. Please follow the assembly instructions carefully. ® After a period of storage, and/or nonuse, the Weber gas barbecue and
Streszczenie treści zawartej na stronie nr. 3
W WA ARR RRA ANTY NTY,, G GA AR RA ANTÍA, NTÍA, G GA AR RA ANTIE NTIE 3 There are no other express warrants except as set forth herein and any applicable implied warranties WARRANTY of merchantability and fitness are limited in duration to the period of coverage of this express written ® Weber-Stephen Products Co. (Weber) hereby warrants to the ORIGINAL PURCHASER of this Weber Limited Warranty. Some regions do not allow limitation on how long an implied warranty lasts, so this gas applian
Streszczenie treści zawartej na stronie nr. 4
EXPLODED VIEW, DIAGRAMA DE DESPIECE, VISION ECLATEE 4 1 2 9 10 11 3 12 13 4 14 5 6 7 8 15 16 Before installing components, remove protective film from the stainless steel part. Antes de instalar el componentes, retire la película 17 protectora de la pieza de acero inoxidable. Avant d’installer le composants, retirez la pellicule protectrice de la pièce en acier inoxydable. ® WWW.WEBER.COM
Streszczenie treści zawartej na stronie nr. 5
EXPLODED VIEW LIST, LISTA DEL DIAGRAMA DE DESPIECE, LISTE DE LA VISION ECLATEE 5 1. Lid 7. Bushing 13. Igniter Button Tapa Pasamuros Botón encendedor Couvercle Douille Bouton de l’allumeur 2. Grate 8. Side Burner Box 14. Igniter Module Parrilla Caja del quemador lateral Módulo encendedor Grille Boîtier du brûleur latéral Module de l’allumeur 3. Side Burner 9. Side Burner Cap 15. Screw Anchor Quemador lateral Tapa del quemador lateral Ancla de tornillo Brûleur latéral Cache du brûleur latéra
Streszczenie treści zawartej na stronie nr. 6
6 INSTALLATION OPERATING “ISLAND” STRUCTURE CONFIGURATION OPTIONS Liquid Propane (LP) gas supply is easy to use and gives you more cooking control than There are many available options for locating the major components of your Island charcoal fuel. structure.Your major components are: • These instructions will give you the minimum requirements for assembling your 1) The Built in Grill ® Weber gas Side Burner. Please read the instructions carefully before using your 2) Gas supply enclosure ®
Streszczenie treści zawartej na stronie nr. 7
INSTALLATION 7 LOCATING YOUR BUILT-IN SIDE BURNER APPLIANCE When determining a suitable location for your Built-In Side Burner installation, give attention to concerns such as exposure to wind, proximity to traffic paths, and keeping ® any gas supply lines as short as possible. Never locate the Summit Built-In Side Burner B in a garage, breezeway, shed, under overhang, or other enclosed area. Locate the Side Burner and structure so there is enough room to safely evacuate the area in case of
Streszczenie treści zawartej na stronie nr. 8
8 INSTALLATION BUILT-IN GAS LINE LOCATIONS GENERAL CONSTRUCTION DETAILS ® • Summit Built-In Side Burner unit should be on site before construction begins. 1 • Provide access for a corrugated gas line depending on the location of the side burner in relation to your main gas supply and regulator position. • Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid possible damage to gas supply lines. Exercise caution when pulling gas lines through built-in structure. •
Streszczenie treści zawartej na stronie nr. 9
INSTALLATION 9 6) Secure the rear of the Side Burner box to counter top by adjusting bracket at back of Side Burner box. Tighten wing nuts. 7) Connect the 3/8 inch (9.52 mm) stainless steel corrugated gas line to the Side Burner valve located underneath the Side Burner. CAUTION: Before continuing installation- you must connect the Side Burner gas line to the main gas supply, then test all Side Burner gas connections for leaks. See “CONNECTING GAS SUPPLY” section and “GAS LEAK TESTING” sec
Streszczenie treści zawartej na stronie nr. 10
10 INSTALLATION/GAS INSTRUCTIONS 9) Install remaining components. TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION We recommend that this installation be done by a LICENSED professional. General Specifications for Piping Note - Contact your local municipality for building codes regulating outdoor gas grill installations. In absence of Local Codes, you must conform to the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54. • This appliance is designed to operate at 11 inches of water
Streszczenie treści zawartej na stronie nr. 11
GAS INSTRUCTIONS 11 3) The minimum size of the ventilation hole (s) should not be less than 1/4 inch. TEST CONNECTIONS 4) The ventilation openings in the sidewalls should not allow venting into All connections and joints must be thoroughly tested for leaks in accordance with local the empty or “hollow” area of the “island” . If a gas leak should occur or codes and all listed procedures in the latest edition of the National Fuel Gas Code ANSI the LP cylinder should vent in the LP cylinder e
Streszczenie treści zawartej na stronie nr. 12
12 CONNECTING GAS SUPPLY CONNECT GAS SUPPLY DANGER 1) Uncap the flare fitting from the optional side burner connection located inside the ® Use of any hose and regulator assembly other than that Summit Built-InTank Cabinet (#21280). 2) Connect the corrugated gas line to the side burner Connection. provided or recommended by Weber-Stephen Products Inc. could be dangerous, and may not provide adequate gas ® supply to the Summit Built-In gas grill, and could result in a fire or an explosio
Streszczenie treści zawartej na stronie nr. 13
CONNECTING GAS SUPPLY 13 TEST CONNECTIONS IMPORTANT LP CYLINDER INFORMATION All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.1/NFPA 54. DANGER ® NEVER store a spare LP Cylinder under or near Weber DANGER gas appliances. Do not use an open flame to check for gas leaks. Be sure NEVER fill the tank beyond 80% full. there are no sparks or open flames in the area while you Failure
Streszczenie treści zawartej na stronie nr. 14
14 CONNECTING GAS SUPPLY Some LP tanks have differing top collar assembles. (The top collar is the metal protective ring around the valve.) One series of tanks mount with the valve facing front (a). The other tanks mount with the valve facing away from the fuel scale (b). Weber recommends the use of cylinder manufacturer’s Manchester and Worthington, with a 47.6 lb water capacity. Other cylinders may be acceptable for use with the appliance provided they are compatible with the appliance re
Streszczenie treści zawartej na stronie nr. 15
GAS LEAK TESTING 15 Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak. CHECK SIDE BURNER COMPONENT Check: 1) Side burner lines to valve connections. 1 1 2) Side burner line to side burner orifice. 3) Side burner hose to side burner bulkhead. WARNING: If there is a leak at connection (1, 2 or 3), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If
Streszczenie treści zawartej na stronie nr. 16
GAS INSTRUCTIONS 16 Note: A refill will last about 18-20 hours of cooking time at normal use. The fuel scale SAFE HANDLING TIPS FOR LIQUID PROPANE GAS will indicate the propane supply so you can refill before running out. You do not have CYLINDERS to run out before you refill. • Liquid Propane (LP) gas is a petroleum product as are gasoline and natural gas. • Treat “empty” LP cylinders with the same care as when full. Even when the LP LP gas is a gas at regular temperatures and pressures.
Streszczenie treści zawartej na stronie nr. 17
OPERATING INSTRUCTIONS 17 SIDE BURNER LIGHTING INSTRUCTIONS Summary lighting instructions are inside the left hand cabinet door. DANGER Failure to remove the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up which can cause serious bodily injury or death. 1) Remove the Side Burner lid by pushing down slightly on one end while lifting from the other end. Store the Side Burner id in y
Streszczenie treści zawartej na stronie nr. 18
18 OPERATING INSTRUCTIONS MANUALLY LIGHTING THE SIDE BURNER DANGER Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up which can cause serious bodily injury or death. 1) Remove the Side Burner lid by pushing down slightly on either end. 2 2) Check that the side burner valves are turned OFF. (Push knobs in and turn clockwise to ensure that they are in the off positi
Streszczenie treści zawartej na stronie nr. 19
SIDE BURNER TROUBLESHOOTING 19 PROBLEM CHECK CURE Side Burner does not light. Is gas supply off? Turn supply on. The excess flow safety device, which is part To reset the excess flow safety device turn all burner control knobs and the cylinder of the barbecue to cylinder connection, may valve off. Disconnect the regulator from the cylinder. Turn burner control knobs to have activated. START/HI. Wait at least 1 minute. Turn burner control knobs to “OFF”. Reconnect the regulator to the cylind
Streszczenie treści zawartej na stronie nr. 20
20 GENERAL MAINTENANCE BURNER FLAME PATTERN ® The Weber gas side burner is manufactured to perform with the proper air and gas mixture. The correct flame pattern is shown. 1) Burner cap 2) Tips occasionally flicker yellow 3) Light blue 4) Dark blue 1 If the flames do not appear to be uniform throughout the burner Head, follow the burner cleaning procedures. 4 • Remove Side Burner Cap(a) and wash with a soft cloth and a soap and water solution. 3 • Brush debris from Burner Head(b) using a non