Streszczenie treści zawartej na stronie nr. 1
™
IntelliG 1200
Model 4024 and 4024H
GARAGE DOOR OPENER
OPERATION AND MAINTENANCE MANUAL
® ®
Includes INTELLICODE 2 Remote Control. Safe-T-Beam System must be installed to close door.
For use only with residential sectional or one piece overhead garage doors.
® ®
Homelink and Car2U compatible.
For Answers and Assistance:
1.800.354.3643
or visit www.geniecompany.com
WARNING: To reduce the risk of injury to persons or damage to property – Use this opener only with a one piece
or sectional door
Streszczenie treści zawartej na stronie nr. 2
SAFETY INFORMATION OVERVIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMATION CONVENTIONS USED IN THESE INSTRUCTIONS Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual. If you have questions or do not understand the information presented, call your nearest tr
Streszczenie treści zawartej na stronie nr. 3
OPENER FEATURES INTELLICODE® 2 Access Security System A new generation superior encryption system that enhances the security of the door opener by continuously changing the access code each time the remote is used. The door opener responds to each new code only once. An access code copied from a working system and tried again will not control the door opener. Wall Console, Series III Operates door opener from inside garage. The Wall Console has an Indicator Light with: Open/Close, Sure-Loc
Streszczenie treści zawartej na stronie nr. 4
TABLE OF CONTENTS Section ....................................................................................Page Safety Information .................................................................................................... 2 Opener Features & Safety Features ................................................................... 3 Table of Contents ....................................................................................................... 4 Installation Important Installa
Streszczenie treści zawartej na stronie nr. 5
Begin here after the opener's physical assembly and installation has been completed. There are no assembly or installation steps included in this manual. Contact your Genie® Professional Dealer for an installation poster, if required, or visit www.geniecompany.com to download a PDF file. The following mechanical assembly tasks must be completed before continuing. Powerhead and rail are bolted to each other (An illustration is shown on page 11) Example illustrations of the following ite
Streszczenie treści zawartej na stronie nr. 6
©2010 The Genie Company 12/2010 6 NOTICE I IF DOOR BECOMES OBSTRUCTED PULL DOWN ON HANDLE WARNING PROGRAMMING LIMITS & FORCE 1 (Continuing from Installation Poster if provided) � Make sure doorway is in view and clear of obstacles and people to avoid injury or damage to property. SETTING & TESTING LIMITS AND FORCE � DO NOT operate this unit from wall console before The OPEN (UP) and CLOSE (DOWN) Door Limit positions are controlled by making LIMITS and FORCE are set. Severe damage to the a
Streszczenie treści zawartej na stronie nr. 7
©2010 The Genie Company 12/2010 7 NOTICE I IF DOOR BECOMES OBSTRUCTED PULL DOWN ON HANDLE B) OPEN DOOR TRAVEL LIMIT PRESS and HOLD until door is FULLY OPEN then RELEASE 6 7 8 PRESS and PRESS and RELEASE RELEASE Watch door move Door Limits are set. Both LEDs flash Blue and go OFF. Continue with SEE long Blue LED Step 9 SET FORCE. NOTE: You can start and stop door flashing movement using either buttons until door is in correct open or closed position. 10 SET FORCE Force is set automa
Streszczenie treści zawartej na stronie nr. 8
©2010 The Genie Company 12/2010 8 CONTACT REVERSE TEST WARNING The Force and Limit settings on the previous page MUST be COMPLETED before Contact A moving door can cause serious injury or death. Reverse testing. 1. Keep people clear of opening while door is moving. 2. Do NOT allow children to play with opener, including 1. Test. wall console, remote, or wireless keypad. � Open garage door using wall console. 3. During programming, door opener could begin to run, – Place a 2" x 4" boa
Streszczenie treści zawartej na stronie nr. 9
©2010 The Genie Company 12/2010 9 PROGRAM INTELLICODE® 2 REMOTE TO POWERHEAD FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM 2 Bring remote(s) to powerhead location. WARNING Begin with Step 1 and continue through Step 7 for each button to be programmed. A moving door can cause serious injury or death. NOTE: The following instructions are for the remote(s) provided with this opener. This 1. Keep people clear of opening while door is moving. remote is preset for use with the IntelliCo
Streszczenie treści zawartej na stronie nr. 10
©2010 The Genie Company 12/2010 10 Homelink® programming OPTIONAL PROGRAMMING POWERHEAD TO Homelink®, Car2U®, or IntelliCode® 1 REMOTES and IntelliCode® 1 WIRELESS KEYPADS If your Homelink® has been previously programmed to an Genie® opener begin with Step 1 and continue through Step To complete any of these tasks you MUST have at least one Genie® IntelliCode® 2 remote 5 and 6 of the Homelink® section below. button already programmed to the powerhead present. If your Homelink® has not
Streszczenie treści zawartej na stronie nr. 11
REFERENCE - POWERHEAD & RAIL ASSEMBLED VIEW RÉFÉRENCE – VUE DE LA TÊTE D’ALIMENTATION & DU RAIL ASSEMBLÉ REFERENCIA - VISTA DEL CABEZAL ELÉCTRICO Y RIEL ENSAMBLADOS NOTE: Use wall console and safety sensors provided with this unit. Do NOT substitute wall console or safety sensors. REMARQUE: Utilisez la console sur le mur et les capteurs de sécurité fournis avec cet appareil. NE PAS substituer la console du mur ou les capteurs de sécurité. NOTA: Use la consola de pared y los sensores de segu
Streszczenie treści zawartej na stronie nr. 12
NOTICE IF DOOR BECOMES OBSTRUCTED I PULL DOWN ON HANDLE 3 TYPICAL SECTIONAL DOOR INSTALLATION FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM INSTALLATION TYPIQUE SUR UNE PORTE SECTIONELLE .................................POUR OBTENIR DE L’AIDE-1-800-35-GENIE INSTALACIÓN HABITUAL DE UNA PUERTA SECCIONAL ................................. PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE *If required direct wiring of power supply to opener must be installed by a licensed electrician. Power cord must
Streszczenie treści zawartej na stronie nr. 13
I IF DOOR BECOMES OBSTRUCTED PULL DOWN ON HANDLE TYPICAL ONE PIECE DOOR INSTALLATION ........... FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM INSTALLATION TYPIQUE D’UNE PORTE DE GARAGE D’UNE PIÈCE .............POUR OBTENIR DE L’AIDE-1-800-35-GENIE INSTALACIÓN HABITUAL DE PUERTA DE UNA SOLA PIEZA ................................... PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE *If required direct wiring of power supply to opener must be installed by a licensed electrician. Power cord must r
Streszczenie treści zawartej na stronie nr. 14
OVERVIEW OF POWERHEAD CONTROLS 4 This section describes the simple programming Programming Overview functions. Use this page to familiarize yourself with the There are four Powerhead program menus: buttons and LED indicators used to program the opener. Remote Program (Default menu) NOTE: These and buttons are for programming use only. Do NOT use these buttons to operate the opener. Limits Program Speed Program* Force Program* Programming steps for Limits and remotes are found on pages 6
Streszczenie treści zawartej na stronie nr. 15
OVERVIEW - REMOTES AND OPTIONS 5 LOST OR STOLEN REMOTE - CLEARING MEMORY WARNING Clearing remotes from powerhead memory will A moving door can cause serious injury or death. clear ALL programmed remotes and wireless 1. Keep people clear of opening while door is keypad. moving. 2. Do NOT allow children to play with opener, NOTE: Follow the PROGRAM REMOTE TO including wall console, remote, or wireless POWERHEAD steps to re-enter remaining or new keypad. remotes. See page 9. 3. Dur
Streszczenie treści zawartej na stronie nr. 16
ATTENTION If your garage door opener has a Serial Number sticker which looks like this, in which the first two numbers are 10 or higher, your opener is equipped with INTELLICODE®2. MODEL AC SR3 THE GENIE COMPANY FCC ID: B8Q AC SR3 Residential Door Operator IC: 2133A-CSD1D 120V. 60HZ. 5A S/N:10XXXXXXXXXXXX FOR HELP CALL 1-800-35GENIE OR WWW.GENIECOMPANY.COM Programming remote to previously installed If you have another garage door opener that does NOT have IntelliCode® 1 Genie® garage door o
Streszczenie treści zawartej na stronie nr. 17
TRANSMITTER COMPLIANCE STATEMENT Transmitters comply with all United States and Canadian legal requirements as of the date of manufacture. No warranty is made that they comply with all legal requirements of any other jurisdiction. If transmitters are to be used in another country, the importer must determine compliance with any local laws and regulations which may differ from United States and Canadian requirements prior to use. Los transmisores cumplen con todas las reglamentaciones legale
Streszczenie treści zawartej na stronie nr. 18
WARNING WARNING � Garage door hardware (springs, cables, brackets, Use wall console supplied with opener. Other pulleys, etc.) are under extreme pressure and approved wall consoles may be available. tension. Unapproved or incompatible wall consoles can � DO NOT attempt to repair or adjust door cause the opener to operate unexpectedly. springs or any hardware, and DO NOT OPERATE Safe-T-Beam® (STB) SYSTEM CHECK garage door automatically or manually if door is improperly balanced or
Streszczenie treści zawartej na stronie nr. 19
NOTICE IF DOOR BECOMES OBSTRUCTED PULL DOWN ON HANDLE CARRIAGE ENGAGE/DISENGAGE Use Release Handle to manually connect or release chain or belt bullet to Carriage. TO RELEASE CARRIAGE: CHANGE LIGHT BULBS 1. Pull handle DOWN then let go. 2. Manually move door until carriage releases from bullet. 3. Raise or lower door manually. WARNING � Observe all safety warning and precautions! Improper light bulb removal or replacement could result in Death or Serious Injury. � Disconnect pow
Streszczenie treści zawartej na stronie nr. 20
B/W W B/W W This opener has a Serial Number sticker in which the serial Open/Close Button numbers begin with 10 or higher. Open and closes door from inside garage ATTENTION Sure-Lock™ Button If your garage door opener has a Serial Number sticker which – LOCK disables controls looks like this, in which the first two numbers are 10 or higher, your opener will operate using this Series III wall control. after door is completely MODEL AC SR3 THE GENIE COMPANY closed FCC ID: B8Q AC SR3 R