Streszczenie treści zawartej na stronie nr. 1
Bell System (Telephones) Ltd.
BSX
Isolated Audio Door Entry System
2 to16 Way, 1 or 2 Door
Installation & Operation Manual
This manual applies to the following BSX Systems: –
BSX 8 – Up to 8 flats 1 Door
BSX 8-2 – Up to 8 flats 2 Doors
BSX 16 – Up to 16 flats 1 Door
BSX 16-2 – Up to 16 flats 2 Doors
The systems are for use with :-
801 Audio Phone
BSLX Audio Phone
PD-142 Issue 1 March 2013
Streszczenie treści zawartej na stronie nr. 2
BSX Isolated Audio Entry System BSX 8 System 801 Audio Phone BSLX Audio Phone PD-142 Issue 1 Installation and Operating Manual Page 2 of 32
Streszczenie treści zawartej na stronie nr. 3
BSX Isolated Audio Entry System TABLE OF CONTENTS INTRODUCTION ................................................................................................................. 5 FEATURES: ...................................................................................................................................................... 5 BASIC SYSTEM OPERATION ............................................................................................ 6 MAKING A CALL .....................
Streszczenie treści zawartej na stronie nr. 4
BSX Isolated Audio Entry System PD-142 Issue 1 Installation and Operating Manual Page 4 of 32
Streszczenie treści zawartej na stronie nr. 5
BSX Isolated Audio Entry System Introduction The BSX2 Door Entry Telephone System is designed for low rise blocks of flats in both the public and private housing sectors. It provides the means for visitors to call an individual resident within the building and to establish two-way speech communication (full duplex) with them. The resident is allowed full control over the callers’ access to the building entrance by means of an electric lock or lock release. The BSX2 control Unit provides
Streszczenie treści zawartej na stronie nr. 6
BSX Isolated Audio Entry System Basic System Operation Making a Call The Entrance panel has a push button for each flat in the building, engraved with the associated flat number. A caller pushes the required button and the phone will start to ring in the flat; this ringing tone will also be heard at the panel. The ringing will continue for 30 Seconds* or until the phone handset is picked up. Once the handset is picked up the resident can talk to the caller for up to 60S*. During this
Streszczenie treści zawartej na stronie nr. 7
BSX Isolated Audio Entry System Equipment & Design Considerations Summary of Equipment Required Quantity Equipment Model Description 1 Control Cabinet BSX8 One entrance, 1 to 8 phones BSX16 One entrance, 9 to 16 phones BSX8-2 Two entrances, 1 to 8 phones BSX16-2 Two entrances, 9 to 16 phones 1-16 (1 per flat) Telephones 801 Standard model 801S Basic model with privacy switch BS-LX Full Feature Model Including Privacy and Door Monitor 1 per Door Entrance Panel VRPn, Vandal Resistant P
Streszczenie treści zawartej na stronie nr. 8
BSX Isolated Audio Entry System when the slide switch is in the mute position the ringer will not sound and the resident will be unaware of calls until the switch is returned to the normal position. Model BS LX Phone The BS LX phone has both Door Status Indication and a sophisticated Ringer Mute facility. Residents may mute the ringing of the BS LX by pushing the mute button on the phone; a red LED illuminates as a reminder. Pushing the same button again will cancel the mute function. Pho
Streszczenie treści zawartej na stronie nr. 9
BSX Isolated Audio Entry System Exit (Egress) Button An exit button is used to unlock the door for the pre-set lock operating time. The input on the controller is designed only for use with a normally open push button. DDA Panels The BSX system can meet the requirements of the Disability Discrimination Act (DDA). Several options are available if required. In the flat the availability of extension sounder and strobe accessories is the main provision. Connection to other more specialist
Streszczenie treści zawartej na stronie nr. 10
BSX Isolated Audio Entry System Power Supply Capability/Limitations Type Rating Description Used on 1 door systems with either fail secure 2A Continuous or fail safe lock releases up to 1A. Cab3 3A Peak Sufficient spare capacity to supply a 200 coded access controller and/or a Pax1 proximity reader. Used on 2 door systems with either fail secure 4A Continuous or fail safe lock releases up to 1A. Cab5 5A Peak Sufficient spare capacity to supply a 200 coded access controller and/or
Streszczenie treści zawartej na stronie nr. 11
BSX Isolated Audio Entry System Installation Important: ● Review the section headed ‘Safety Information’ on Page 31. ● Ensure that ‘Design Considerations’ on Page 7 have been understood. ● Refer to the wiring diagrams from Page 27 onwards. General The major components of the system are fitted with high quality pluggable screw terminal blocks. This enables all the connections to the system to be fully completed, whilst easily isolating individual pieces of equipment during testing and c
Streszczenie treści zawartej na stronie nr. 12
BSX Isolated Audio Entry System Engaged lamp output The engaged lamp output is on when the other door is busy (ringing or talking to a flat). The output can be used drive a busy indicator. Electric Door Release When installing lock releases please allow a little movement on the door, as operation will be impaired if fitted too tight. The Control PCB provides a single pair of outputs for electric lock releases or maglocks. A switch on the control PCB selects fail safe or fail secure, re
Streszczenie treści zawartej na stronie nr. 13
BSX Isolated Audio Entry System Exit Button The exit button input is for a normally open contact button. When pressed the Lock output will activate and the tone will sound for the Lock Time as set on the switches, see BSX2 Controller Settings on Page 14. If the exit input is triggered for longer than the lock time then the lock output will continue to operate until the input is removed. The tone will however stop after the lock time. ‘Exit +’ is the input and ‘Exit –’ is internally con
Streszczenie treści zawartej na stronie nr. 14
BSX Isolated Audio Entry System BSX2 Controller Settings These settings affect only calls etc. for that door PCB. Apart from SW1-5 both PCB’s in a two door system should have the same settings. The two doors can have different settings, though in practice should not as it causes user confusion. See Page 28 for the PCB layout Lock Time DIP SW1(1-2) 1 2 Offset Off Off 3 Seconds* SW1 On Off 5 Seconds On Off (QWDFGHJK) Off On 10 Seconds On On 20 Seconds SW1 Individual Funct
Streszczenie treści zawartej na stronie nr. 15
BSX Isolated Audio Entry System BS-LX Phone Settings 801xx Phone setting The 801 has a jumper for ring volume with low and high settings. The jumper is at the top left of the PCB, has 3 pins and is marked Lo/Hi. The 801S and 801PS have a switch at the right hand side to disable/mute the ringer. PD-142 Issue 1 Installation and Operating Manual Page 15 of 32
Streszczenie treści zawartej na stronie nr. 16
CLO CK YEAR BSX Isolated Audio Entry System The TS2000-BST Time-Clock Module This section describes the operation and programming of the TS2000 Time Clock module for use with the Tradesman’s facility. CAUTION The unit is intended for 12V AC / DC operation only, and must not be connected to the Mains supply or used to switch Mains voltages. Operation N.B. Before programming or setting the clock for the 1st time press the Reset button. Programming may be carried out without 12V power app
Streszczenie treści zawartej na stronie nr. 17
BSX Isolated Audio Entry System Reviewing the Programs Press each time to toggle through the 8 on and off settings. Clearing the Programs The only way of removing a program (e.g. 2 On to Off is no longer required) is to reset the time clock using the Reset button and reprogramming On-Off-Auto Press to toggle through On/Auto/Off modes as indicated by the Timer Status Bar. On mode turns the relay On permanently. Off mode turns the relay Off permanently. AUTO mode keeps the current On or
Streszczenie treści zawartej na stronie nr. 18
BSX Isolated Audio Entry System Testing & Commissioning Safety Before switching on the mains spur, ensure that the connection is correctly made and that the cabinet is correctly earthed as per the section entitled ‘Safety Information’ on Page 31 (Inside back page). Leave the battery disconnected for now. Apply mains power to the control unit and turn on at the power supply switch. Basic Functional test These tests require two people and assume the system is idle, watch out for buttons
Streszczenie treści zawartej na stronie nr. 19
BSX Isolated Audio Entry System Adjusting the 61 Speech Unit The Model 61 Speech Unit has 2 volume controls:- A (Speaker symbol): controls the speech level from phone to panel. B (Microphone symbol): controls the speech level from panel to phone. Initially set both controls to mid-position and adjust each in turn for optimum speech clarity. It should be noted that if either or both controls are turned too high there will be a howling sound caused by acoustic feedback. This problem may a
Streszczenie treści zawartej na stronie nr. 20
BSX Isolated Audio Entry System Troubleshooting Common Faults A very high percentage of calls to our technical support number, regarding new installations, are resolved to faulty wiring. The reasons for these are various: - Broken cores, especially short links, sometimes broken inside the insulation! Connectors clamped onto the insulation instead of copper. Wire in the wrong side of a rising clamp connection, the clamps need to be unscrewed far enough to stop the wire going “underneat