Streszczenie treści zawartej na stronie nr. 1
Oxygen Series
Oxygen 8 v2, Oxygen 49, Oxygen 61
User Guide
Streszczenie treści zawartej na stronie nr. 2
English Oxygen Keyboard Line User Guide 1 › Introduction Congratulations on purchasing an Oxygen keyboard from M-Audio. The Oxygen keyboards offer diverse controls and all the programming features and functions you will need to develop your MIDI studio. The Oxygen keyboards come with 25, 49, or 61 full-size, velocity-sensitive keys and eight fully assignable knobs, with 6 fully assignable Transport buttons. The 49- and 61-note models also include 9 fully assignable buttons and 9 assignable
Streszczenie treści zawartej na stronie nr. 3
General The product has the following general features: < USB bus powered < Compatible with Enigma librarian and parameter editor for storing and organizing setups < MIDI Data from controllers • MIDI control number • RPN/NRPN • Program, Bank LSB, Bank MSB • Pitch Bend • GM/GM2/XG SysEx Messages < MIDI Data from buttons: • Note on • Note on/off toggle • MIDI CC on/off toggle • RPN/NRPN • Program, Bank LSB, Bank MSB presets • MIDI Machine Control fu
Streszczenie treści zawartej na stronie nr. 4
Oxygen Keyboard Line User Guide 5 › Driver Installation and Powering the Keyboard Power and Connection via USB You can power the keyboard via USB or an optional external power supply. Use only one method at a time. 1. Check that the on/off switch on the back of the unit is set to “off” 2. Plug in the USB cable provided with the Oxygen keyboard to a free USB port on your computer 3. Plug in the other end of the USB cable to the USB input on the Oxygen keyboard and turn the Oxygen keyboard on
Streszczenie treści zawartej na stronie nr. 5
3. Octave +/- and Transpose Buttons: The Octave buttons allow you to shift the octave of the keyboard up or down to extend the range of the key bed. The left button is for the Octave down function, and the right button is for the Octave up function. The top to bottom range available via the Octave up and down function is 11 octaves. 1. Press Octave + one time for each up octave shift on the keyboard 2. Press Octave – one time for each down octave shift on the keyboard Transpose is a second
Streszczenie treści zawartej na stronie nr. 6
Oxygen Keyboard Line User Guide Back Panel Descriptions 1. DC Power Supply Port: For connection of a 12V DC 250-300mA power supply. (The power supply is an optional accessory and is not included in the package.) 2. USB 1.1 Port: USB 1.1 upstream (Type B) port 3. MIDI Output: The external MIDI Out port is used to connect external MIDI devices such as sound modules, hardware sequencers, and synthesizers. The port will accept a standard 5 pin DIN-type connector. 4. Sustain Pedal Input: The Sus
Streszczenie treści zawartej na stronie nr. 7
7 › Introduction to MIDI Programming Functions Introduction Before you begin exploring the MIDI section of the manual, please refer to the beginning of this guide and read the installation information. It is necessary to install the Oxygen and ensure it is working properly before you begin to work with the MIDI functions. Testing Your Oxygen keyboard with Your Computer Software We recommend that you verify that your software application is properly communicating
Streszczenie treści zawartej na stronie nr. 8
Oxygen Keyboard Line User Guide 8 › Function Buttons Defined Advanced The Advanced Functions feature will put the keyboard into Edit mode, and the keys on the key bed will then call up the assigned programming function written on the panel above them. When the Advanced Function button is pressed, and the keyboard enters edit mode, the LED screen will show three dots along the bottom of the display. Mute The Mute function mutes all MIDI output from the rotary dials, or faders on your Oxygen
Streszczenie treści zawartej na stronie nr. 9
9 › Keybed Functions Defined Control Assign The Control Assign function assigns a MIDI controller message (MIDI CC) to a selected controller. To assign a MIDI CC to a selected controller: 1. Press the Advanced Function button. 2. Press the Control Assign key. 3. Enter the MIDI CC value with the numeric keys. 4. Press the Enter key. The controller that is affected by the Control Assign function is always the last used controller. By default, controller 1 is selected. However, it is poss
Streszczenie treści zawartej na stronie nr. 10
Oxygen Keyboard Line User Guide Control Select The Control Select function selects a MIDI controller for parameter editing. Use the Control Select function to select a MIDI controller before assigning a MIDI CC number to that controller. To select a MIDI controller for editing, move the knob or fader that you want to edit. The last used controller is always the controller that is currently selected for editing. The second method to select a MIDI controller for editing: 1. Press the Advanced
Streszczenie treści zawartej na stronie nr. 11
Data 2 The Data 2 function is located on the key bed. The function of Data 2 depends on the MIDI CC that is currently assigned to the controller that is to be edited. Please refer to Appendix A where each assignable MIDI CC is listed, along with the Data 1, 2 and 3 functions. When editing Data 2 values, the range of values that can be selected is 0-127. It is possible to limit the range of the rotary dials and faders on your Oxygen keyboard. To assign minimum value to a knob or fader: 1. P
Streszczenie treści zawartej na stronie nr. 12
Oxygen Keyboard Line User Guide Velocity Curve The Velocity Curve Select button selects the velocity curve that the keyboard will use to regulate each MIDI note. Oxygen controllers offer 12 different velocity curve settings, 9 curves, and 3 fixed curves. The 3 fixed curves give velocities of 64, 100 and 127. On the Oxygen keyboard: 1. Press the Advanced Function button. 2. Press the Velocity key. 3. Type the number of the desired velocity curve using the key pad, and press the Enter key. Drawbar
Streszczenie treści zawartej na stronie nr. 13
Memory Dump The Memory Dump function sends out a Sys Ex memory dump from your Oxygen keyboard. The memory dump will send out Sys Ex data for the 10 preset memories on the Oxygen line to allow for storing the memories in external software. 1. Press the Advanced Function button. 2. Press the Memory Dump key. A stored Memory Dump can be played back to the Oxygen, and it will automatically read the preset settings from the file. The Memory Dump is standard memory data. This means it is possible
Streszczenie treści zawartej na stronie nr. 14
Oxygen Keyboard Line User Guide 10 › Advanced Programming Functions Introduction to Programming Options MIDI CC (continuous controller) numbers are part of the General MIDI specification and are typically used to control the real-time changing of parameters in musical equipment. For a complete list of standard MIDI controller numbers from 0 to 131, please see Appendix A. As mentioned in Section 6, many of the controls on the Oxygen range are fully programmable. This means that you can assign
Streszczenie treści zawartej na stronie nr. 15
Buttons and Pedal: MIDI CC Description Data 1 Data 2 Data 3 0-119 Standard MIDI CC's - Toggle Value 2 Toggle Value 1 120-127 Channel Mode Messages - Toggle Value 2 Toggle Value 1 128 Pitch Bend Range - Sensitivity Value - 129 Channel Fine Tune - Tuning Amount - 130 Channel Coarse Tune - Tuning Amount - 131 Channel Pressure - Pressure Amount - 132 RPN Coarse Value RPN LSB RPN MSB 133 RPN Fine Value RPN LSB RPN MSB 134 NRPN Coarse Value NRPN LSB NRPN MSB 135 NRPN Fine Value NRPN LSB NRPN MSB 136
Streszczenie treści zawartej na stronie nr. 16
Oxygen Keyboard Line User Guide Setting Toggle Values for the Buttons or Pedal When a standard MIDI CC number is programmed to the assignable buttons or the sustain pedal, the controller will toggle between an on and off value. That means when you press the controller, an on value is sent. When you next press the controller, the off value is sent. The on and off values are set using the Data 3 and Data 2 parameters respectively. Please try the example below; this will cause a button to har
Streszczenie treści zawartej na stronie nr. 17
Assigning MMC Control to a Button 1. Select the button to control the MMC message. 2. Press the Advanced Function button. 3. Press the Control Assign key. Type the number 149 with the keypad, and confirm by pressing the Enter key. 4. Press the Advanced Function button. 5. Press the Channel Assign key. 6. Enter 127 using the key pad, then press Enter. This ensures all receiving devices will respond to the MMC message. 7. Press the Advanced Function button. 8. Press the DATA 2 key and enter a
Streszczenie treści zawartej na stronie nr. 18
Oxygen Keyboard Line User Guide 7 Press the Advanced Function button again followed by the Data 2 key. 8 Enter “0” using the numerical data entry keys. 9 Press the Enter key to confirm. This means when you release the button, a Note Off message will be sent out. 10 Press the Advanced Function button followed by the Data 1 key. 11 Enter “64” using the numerical data entry keys. 12 Press the Enter key to confirm. This means you are sending out MIDI note 64 or E4 each time you press the bu
Streszczenie treści zawartej na stronie nr. 19
Non-Volatile Memory Your Oxygen controller features non-volatile memory, which allows for automatic saving of presets after powering down and restarting. The current controller and channel assignments are stored whether you have stored the setup to a memory location or not. The Program, Bank LSB and Bank MSB data, Global Channel setting, MIDI Out from USB setting and last used memory preset are also stored. Memory Dump Press the Advanced Function button, then the Mem Dump key to send out SysE
Streszczenie treści zawartej na stronie nr. 20
Oxygen Keyboard Line User Guide RPN/NRPNs Non-registered parameter numbers (NRPNs) are device-specific messages that enable the control of synths via MIDI. The MIDI specification defines parameter numbers to allow manufacturers to specify their own controllers. The more common of these have been registered by the MIDI Manufacturer's Association and are part of the MIDI specification (hence the term Registered Parameter Numbers – RPNs). (See Appendix F for additional information.) MIDI controlle