Before using your timer, please read the following instructions carefully.This quality product has been tested and certified to meet applicable Australian and New Zealand electrical and safety standards. Specifications Input: AC 220-240v 50Hz Output 10A resistive load. Operating temperature: -10° C to 40° C. Min setting time: 1 minute. Battery back up: Alkaline button cell battery L1131 MO TU WE TH FR SA SU MO TU WE TH FR SA SU Minute LCD Button Display COUNT DOWN AUTO MANUAL COUNT
Streszczenie treści zawartej na stronie nr. 3
Features Up to 8 ON and OFF switches a day / 56 On and Off switches a week. Option to program individual days or 8 different weekday groups. Minimum switching period is one minute. Summer time / Winter time change over. Easy to read LCD display. Random automatic ON / OFF security feature. Manual override button. Battery back up. Countdown Feature for timing down from 9hrs 59mins Important Safety Precautions Do not use on an extension lead. Do not plug this timer into another time switch. Do not
Streszczenie treści zawartej na stronie nr. 4
Do not open the timer.There are no user serviceable parts inside.Authorised service personnel must perform repairs only. Use a soft cloth to clean casing and display. Do not use chemical or scouring agents. Do not submerge in water. Keep device out of reach of children. Do not use near flammable gases or liquids. Important Before using the timer, the tag needs to be removed from the battery back-up compartment. Loosen screw securing the battery cover and gently slide the tag out from between th
Streszczenie treści zawartej na stronie nr. 5
MO TU WE TH FR SA SU Setting The Time Press and hold the CLOCK button. COUNT DOWN AUTO MANUAL RND ±1H RESET With this held pressed, the Day DAY HOURS MIN. button can be used to select the CLOCK correct day, or the HOURS button used to select the correct hour and the MIN button to select the correct minutes.When the MIN button is released the time will be set with the seconds starting from 0. Either holding down or repeatedly pressing the appropriate button can advance the days, hours and
Streszczenie treści zawartej na stronie nr. 6
For each ON time and each OFF time, the day, hours and minutes must be set. Press the PROG Button once to set the first ON time – you will see ON and number “1” appear on the left of the LCD display. This indicates that you can now enter the first ON time. Press the DAY button to choose the required day, or block of days and then set the hour and minutes using the HOURS and MIN buttons. When you have completed setting the required ON time press the PROG button to validate the entry and move onto
Streszczenie treści zawartej na stronie nr. 7
Manual Override You can choose permanent ON, Permanent OFF and AUTO mode by pressing the Manual ( ) button. Check the display for arrow indicator for Auto or Manual, then the on / off on the left-hand side of the screen.The timer programs will only work in the AUTO ON or AUTO OFF settings. Mode Functions MANUAL OFF Turns off the timer permanently AUTO OFF Starts the set program MANUAL ON Turns on the timer permanently AUTO ON Turns on the timer until it reaches the next Programmed off time and
Streszczenie treści zawartej na stronie nr. 8
activating, the timer will still switch ON and OFF within the set programmes. For example, the Random Mode might switch the timer to OFF even when the timer is switched ON by the set programmes. Please note that if the timer has no set programme, the timer will switch ON and OFF about 1 minute after you enter the Random Mode.To exit Random Mode, press DAY and HOURS buttons again. Summer time / Winter time time change over To change from winter time to summer time press the HOURS and MIN buttons
Streszczenie treści zawartej na stronie nr. 9
The maximum countdown time selection is 9 hrs and 59 mins and the minim MO TU WE TH FR SA SU um countdown time selection is 1 Min. MO TU WE TH FR SA SU After you have selected the countdown time, you can press the MANU COUNT DOWN AUTO MANUAL AL ( ) button to start.The output will RND ±1H COUNT DOWN AUTO MANUAL RND ±1H RESET turn on until the end of the countdown period.You can RESET DAY HOURS MIN. DAY HOURS MIN. pause the countdown any time during the countdown COUNT CLOCK PROG. perio
Streszczenie treści zawartej na stronie nr. 10
Kambrook 12 Month Guarantee KAMBROOK warrants the purchaser against defects in workmanship and material, for a period of 12 months from the date of purchase (3 months commercial use). Guarantee and purchase receipt for this product are to be retained as proof of purchase and must be presented if making a claim under the terms of the KAMBROOK guarantee. KAMBROOK reserves the right to replace or repair the appliance within the warranty period.Warranty does not apply to any defect, deterioration,