Honeywell TRUDRY DR90 user manual

User manual for the device Honeywell TRUDRY DR90

Device: Honeywell TRUDRY DR90
Category: Air Cleaner
Manufacturer: Honeywell
Size: 1.79 MB
Added : 4/25/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell TRUDRY DR90. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell TRUDRY DR90.

For your convenience

If looking through the Honeywell TRUDRY DR90 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell TRUDRY DR90 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell TRUDRY DR90 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell TRUDRY DR90 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell TRUDRY DR90 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell TRUDRY DR90. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TrueDRY™ DR90
PROFESSIONAL INSTALLATION GUIDE
InCluDED In ThIs BOx
B C D E
A
OPTIONAL CONTROLS SOLD SEPARATELY
G
F TrueDRY™ DR90
PROFESSIONAL INSTALLATION GUIDE
INCLUDED IN THIS BOX
B C D E
A
OPTIONAL CONTROLS SOLD SEPARATELY
F TrueDRY™ DR90 G
PROFESSIONAL INSTALLATION GUIDE
AINCLUDED IN THIS B B OX C D E
F G OPTIONAL CONTROLS SOLD SEPARATELY
Tools r 3/8-in. hex drive equired to install TrueDRY DR90 G1 G2 B A 10-in. duct collar (1) TrueDRY™ DR90 (1) G3 G4
Standar 1/2-in. diameter drain

Summary of the content on the page No. 2

Installation Checklist Included in This Box A TrueDRY™ DR90 (1) B 10-in. duct collar (2) C 6-in. duct collar (1) D MERV II Filter (1) E Filter Door (1) F Installation Guide Control Options (sold separately) G1 Prestige Comfort System G2 True IAQ G3 H8908 Manual Dehumidistat G4 VisionPro IAQ Control (included with DR90VPIAQ) Tools Required (not supplied) • 3/8-in. hex drive • Drill or duct cutting tool • Wir e stripper/cutter • Standar d scr ewdriver • Duct tape • 10-in. r ound duct and s

Summary of the content on the page No. 3

TM TrueDRY ABOUT YOUR NEW DEHUMIDIFIER Benefits .................................. 2 Maintaining Ideal Humidity . . . . . . . . . . . . . . . . . . . 2 Control Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Specifications .............................. 4 InsTAllATIOn Install to Fit Your Application .................. 5 Plumbing .................................. 6 Terminal Description ......................... 7 Wiring .................................. 7 Checkout ..........

Summary of the content on the page No. 4

About the T rueDR Y™ DR90 Dehumidifier The Honeywell TrueDRY DR90 ensures the home is maintained at proper humidity levels through its high performance and efficiency. Benefits • Removes up to 90 pints of water per day fr om the indoor air . • Built-in fr esh air supply • Energy Star Rated Maintaining Ideal humidity Dew points and relative humidity (RH) affect the way your body senses heat. Higher humidity levels cause the air to feel much hotter than the actual tempera

Summary of the content on the page No. 5

Control Options The TrueDRY DR90 may be used with one of the following external controls: Prestige™ Comfort system • Contr ols both heating/cooling and dehumidification. • Shows actual and desir ed humidity on an intuitive digital display . • Wir eless sensor for displaying outdoor temperatur e and humidity . • Maintenance and service r eminders. • High definition color display . VisionPRO IAQ Total Comfort system (YTh9421C1010) • Contr ols both heating/cooling

Summary of the content on the page No. 6

Specifications Install TrueDRY DR90 according to National Electric Codes. Dry-Bulb Temp Intake humidity Capacity (Pints/Day) 80°F 60% RH 90 70°F 60% RH 77 60°F 60% RH 47 home size Dehumidifier Capacity Required to Maintain Desired Indoor Rh* (square ft) 60% Rh Indoor 50% Rh Indoor 40% Rh Indoor (pints/day) (pints/day) (pints/day) 2080 49–54 55–58 71–78 2600 61–68 65–72 90–97 3120 75–82 79–86 95–110 * Based on extreme climates where outdoor humidity is 70-90% RH. For less extreme climates, la

Summary of the content on the page No. 7

Install to Fit Your Application Flex duct is recommended in connecting to the TrueDRY DR90 collars to reduce vibration noise. Duct sizing: Use minimum 10-in. diameter round for duct lengths up to 25 ft. Minimum 12-in. required for lengths longer than 25 ft. Duct branches from the main inlet/exhaust should be minimum 10-in. round for 2-3 branches, and 12-in. round or larger for 4 branches or more. For the optional fresh air ventilator port, use 6-in. round, insulated duct for lengths up to

Summary of the content on the page No. 8

Install to Fit Your Application (continued) Dedicated Return to Main supply AIR HANDLER Ideal when… C RETURN SUPPLY • Drying a specific ar ea of the house. • Running with A/C operation r equir es backdraft damper on the exhaust port to minimize backdraft when T rueDR Y SEPARATE DR90 is not on but A/C is. RETURN BACKDRAFT DAMPER TrueDRY M27326 Dedicated Return to Main Return AIR HANDLER Ideal when… D RETURN SUPPLY • Drying a specific conditioned or unconditioned area, suc

Summary of the content on the page No. 9

+ Terminal Description CAuTIOn: low voltage hazard. Can cause equipment damage. Disconnect hVAC equipment before beginning installation . * nOTE: The outer screws on the terminal block secure the block to the chassis. They are not used for wiring. A wiring terminal block is located on the side panel of the TrueDRY unit. The four terminals for the terminal block (reading from left to right in the photo) are: DHUM: Compressor and fan operation for dehumidification R: DR90 24V output FAN: F

Summary of the content on the page No. 10

+ + Wiring (continued) HVAC MECHANICAL DEHUMIDISTAT R C W Y G DRY CONTACTS Follow this diagram for ducted DPDT RELAY, operation 2.6A with an external humidity RRc W Y G control. DHUM R C FAN TrueDRY M29840 THERMOSTAT HVAC AT120 EARD-6 MECHANICAL R C W Y G R DEHUMIDISTAT C DRY W8150A G CONTACTS R DAMPER Follow this C diagram for C AUX ducted W DPDT operation RELAY, G REMOTE with 2.6A external Rc W R Y G humidity and ventilation control. DHUM R FAN C TrueDRY THERMOSTAT M29841 TrueDry

Summary of the content on the page No. 11

+ Wiring (continued) THERMOSTAT 1 HVAC RRc C W Y G R R Follow this diagram if using C C TrueIAQ OUTDOOR SENSOR W TrueDRY DR90 with a powered SENSOR SENSOR (PROVIDED) Y dehumidistat such as TrueIAQ In % 6840 SWITCH G Out % (DG115EZIQ). 7655 W 2 PM 12:15 G VENT EARD-6 VENT DEHUM DEHUM TrueDRY HUM HUM 1 IF A THERMOSTAT OTHER THAN A TH5110, TH5220, TH5320, TH6110, TH6220, TH6320, TH8110, TH8320, OR TH8321 IS USED, A RELAY MAY BE REQUIRED TO ISOLATE THE G WIRE. 2 PROGRAM ISU SETTING 60 TO Ø T

Summary of the content on the page No. 12

Checkout Apply power to TrueDRY DR90. Turn the humidity control to a low RH% level to initiate a dehumidification call. Confirm that the TrueDRY DR90 compressor and fan turn on. The furnace blower will also turn on to circulate air. This will take up to two minutes. Be sure to turn the control to the desired RH% or to Off when checkout is complete. Cleaning On an annual basis, maintenance is required to ensure TrueDRY runs at peak efficiency. Unplug TrueDRY DR90 before beginning Remove filter

Summary of the content on the page No. 13

Technical Description STRAINER/FILTER TrueDRY DR90 uses a refrigeration system similar to COMPRESSOR DRIER an air conditioner to remove heat and moisture from incoming air and add heat to the air that is discharged. Hot, high-pressure refrigerant gas is routed from the CONDENSER compressor to the condenser coil. The refrigerant is cooled and condensed by giving up its heat to the air that is about to be discharged from the unit. The CAPILLARY TUBES refrigerant liquid then passes through a

Summary of the content on the page No. 14

Troubleshooting (continued) Problem Recommended Troubleshooting steps Fan does not run with 1. Loose connection in fan circuit. ventilation activated. 2. Obstruction prevents fan rotation. Compressor runs briefly 3. Defective fan. but cycles on & off with 4. Defective fan relay. humidity control turned to 5. Defective fan capacitor. ON. Evaporator coil frosted 1. Defrost thermostat loose or defective. continuously, low de- 2. Low refrigerant charge. humidifying capacity. 3. Dirty air filter(

Summary of the content on the page No. 15

Parts List Figure Description Part number Reference 1 TrueDRY with no controls DR90A1000 2 TrueDRY with VisionPRO IAQ Control DR90VPIAQ 3 Prestige Comfort System YTHX9321R5003 4 VisionPRO IAQ Total Comfort Control YTH9421C1010 5 TrueIAQ Digital IAQ Control DG115EZIAQ 6 H8908D Manual Dehumidistat H8908DSPST 7 Automatic ventilation control W8150A1001 8 Motorized ventilation damper EARD 6 Compressor run capacitor 50049536-001 Blower assembly 50027976-001 9 Filter 50049536-003 10 6-in. Duct collar

Summary of the content on the page No. 16

5-Year Limited Warranty Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and service, for a period of five (5) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from w


Alternative user manuals
# User manual Category Download
1 Honeywell 11500 User manual Air Cleaner 260
2 Honeywell 11255 User manual Air Cleaner 27
3 Honeywell 13350 User manual Air Cleaner 25
4 Honeywell 12500 User manual Air Cleaner 50
5 Honeywell 14500 User manual Air Cleaner 54
6 Honeywell 13500 User manual Air Cleaner 4
7 Honeywell 18150 Series User manual Air Cleaner 2
8 Honeywell 18150 User manual Air Cleaner 3
9 Honeywell 16200 User manual Air Cleaner 66
10 Honeywell 17000 User manual Air Cleaner 34
11 Honeywell 203365A User manual Air Cleaner 1
12 Honeywell 17005 User manual Air Cleaner 2
13 Honeywell 18155 User manual Air Cleaner 2
14 Honeywell 50100 User manual Air Cleaner 10
15 Honeywell 50200 User manual Air Cleaner 2
16 Sony PK-HS1FL User manual Air Cleaner 1920
17 Sony PK-R1FL User manual Air Cleaner 11
18 Philips AC4053 User manual Air Cleaner 30
19 Philips AC4002/00 User manual Air Cleaner 13
20 Philips AC4055 User manual Air Cleaner 9