Summary of the content on the page No. 1
®
GE Monogram
Installation
Instructions
36" Gas
Cooktops
Models
ZGU3650
Summary of the content on the page No. 2
Before you begin—Read these instructions completely and carefully. IMPORTANT: Save these instructions for local inspector’s use. IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INSTALLER: Be sure to leave these instructions with the Consumer. NOTE TO CONSUMER: Keep these instructions with your Owners Manual for future reference. This appliance must be properly grounded. See “Power Supply”, page 5. CAUTION WARNING CAUTION ATTENTION Cet appareil doit être correctement mis à la terre
Summary of the content on the page No. 3
Design Information G as Updraft Cooktop ZGU3650 36" gas updraft cooktops For those who prefer gas heat for cooking, the Monogram built-in gas updraft cooktop offers the cooking method of choice. These models are shipped for natural gas operation. These cooktops are only 3" deep They can be converted to liquid propane. (Order and can be installed over cabinet JXLP56 conversion kit). drawers. 4-5/8" Min. Dimensions to Vertical 36" Combustible and clearances Surface 19-3/4" 8-13/16" Min. 18-1/8"
Summary of the content on the page No. 4
Installation Preparation G as Updraft Cooktop • Self-adhesive gasket • Carpenter’s square • 1/2" NPT x 3/4" • 5 foot AGA-certified Tools and (supplied) • Pipe wrench I.D. or 1/2" I.D. flexible metal Materials • Two clamping • Manual gas line flare union adaptor appliance connec- brackets and shut-off valve for connection to tor, 3/4" or 1/2" Required screws (supplied) • 3/4" NPT x 3/4" regulator I.D. to match gas • Gas pressure I.D. or 1/2" NPT x • Gas-resistant pipe supply line: regulator (supp
Summary of the content on the page No. 5
Installation Preparation G as Updraft Cooktop Gas supply: Power supply These cooktops are designed to operate on locations natural gas at 4" of water column pressure or on LP gas at 10" of water column pressure. 2" Min. –These cooktops are shipped from the Below factory set for natural gas. If you decide Bottom to use this cooktop with LP gas, conversion of 1-5/8" Counter From adjustments must be made by a service Right of technician or other qualified person. Cutout JXLP56 conversion kit is re
Summary of the content on the page No. 6
Installation G as Updraft Cooktop Gasket Note: If the cooktop is installed into a 36" Step base cabinet, the pressure regulator MUST BE installed to the bottom of the cooktop before Countertop 1 the cooktop is placed into the cabinet. Install • Remove packaging from the cooktop. Cooktop • To insure a good fit, position the cooktop over the cutout opening and carefully lower into place. Check edges all the way around to be sure all cutout edges are concealed and there are no gaps. • Carefully, li
Summary of the content on the page No. 7
Installation Gas Updraft Cooktop • Install the supplied pressure regulator and nipple in the gas line as close to the cooktop Step inlet as possible. Allowances for ventilation 2 ducting may be necessary. Regulator –Make sure the regulator is installed in the Install right direction. Pressure • Install a manual shut-off valve in the gas line in an easily accessible location. Solid Piping Regulator or Flexible Connector Note: Instead of using solid piping to connect to pressure regulator, an appr
Summary of the content on the page No. 8
NOTE: While performing installations described in this book, safety glasses or goggles should be worn. To obtain specific information concerning any ® Monogram product or service, call GE Answer Center consumer information service at 800.626.2000—any time, day or night. For Monogram local service in your area, call 1-800-444-1845. NOTE: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are Pub. No. 49-80000-1 ® subject to change