Whirlpool ACE184XR0 user manual

User manual for the device Whirlpool ACE184XR0

Device: Whirlpool ACE184XR0
Category: Air Conditioner
Manufacturer: Whirlpool
Size: 1.16 MB
Added : 6/16/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Whirlpool ACE184XR0. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Whirlpool ACE184XR0.

For your convenience

If looking through the Whirlpool ACE184XR0 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Whirlpool ACE184XR0 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Whirlpool ACE184XR0 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Whirlpool ACE184XR0 User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Whirlpool ACE184XR0 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Whirlpool ACE184XR0. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AIR CONDITIONER
Use & Care Guide
For questions about features, operation/performance, parts,
accessories or service, call: 1-800-253-1301 in the U.S.A.
ACONDICIONADOR
DE AIRE
Manual de Uso y Cuidado
Si tiene preguntas respecto a las características, funcionamiento,
rendimiento, partes, accesorios o servicio técnico,
llame al: 1-800-253-1301 en los EE. UU.
Table of Contents/Índice ..................................... 2
1188127A

Summary of the content on the page No. 2

TABLE OF CONTENTS AIR CONDITIONER SAFETY .........................................................2 Starting Your Air Conditioner—Rotary Controls........................14 Changing Air Direction ...............................................................16 INSTALLATION REQUIREMENTS ................................................3 Normal Sounds...........................................................................16 Tools and Parts ........................................................

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions: Plug into a grounded 3 prong outlet. Do not use an extension cord. Do not remove ground prong. Unplug air conditioner before servicing. Do not use an adapter. Use two or more people to move and install air conditioner. SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS NOTE: Installation parts are supplied for double-hung windows up to 4

Summary of the content on the page No. 4

Window installation Electrical Requirements Window opening measurements:  26¹⁄₂" (66.1 cm) minimum to 40" (101.6 cm) maximum WARNING opening width.  20" (50.8 cm) minimum opening height. Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. A B Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. A. 26¹⁄₂" (66.1 cm) minimum Ground wire must be connected to ground screw loc

Summary of the content on the page No. 5

RESET RESET TEST TEST This room air conditioner is equipped with a power supply cord Recommended ground method required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is crushed, the This air conditioner must be grounded. This air conditioner is electronics detect leakage current and power will be disconnected in a fraction of a second. equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock h

Summary of the content on the page No. 6

1. Remove air conditioner from carton and place it on cardboard. A 2. Remove shipping screws from each side wall of cabinet. B C A A A. Shipping screws 3. Remove front panel from air conditioner and set aside. 4. Remove ground screw and ground wire from front of air E D conditioner base. Save ground screw. F A. Wire ties (2) D. Compressor flange B. Unit support bracket E. Remove this screw A C. Upper shipping bracket F. Lower shipping bracket 3. Remove screw from end of lower shipping bracke

Summary of the content on the page No. 7

4. Adjust the cabinet until the distance on each side is the same. 9. Place cabinet back into the window with right filler board tight Then add ¹⁄₈" (3.2 mm) for the final measurement to be used against window channel. Insert left filler board into window in the next step. channel. A B A Top View B C AB A. Right filler board A. Window sash B. Window channel B. Empty cabinet C. Window channel 10. Push left filler board against side-mounting angle and attach with two ¹⁄₂" hex-head screws. Fro

Summary of the content on the page No. 8

Level cabinet 1. Use a level to check that cabinet is level side to side. A 2. Use a ³⁄₃₂" drill bit to drill 2 starter holes through the 2 holes in the cabinet and into the windowsill. 3. Attach cabinet to window with 2 - #10 - 12 x ³⁄₄" wood screws. A B C C B C A. Bolts B. Angle supports B C. Vertical supports A B 6. Measure inside width of window frame. 7. Cut foam window sash seal with square ends to fit. A. Level B. Wood screw 8. Hold cabinet to prevent it from falling. Raise window

Summary of the content on the page No. 9

Installing the Cabinet Through a Wall  Handle air conditioner gently.  Use 1" (2.5 cm) or thicker lumber for wood frame.  Be sure your air conditioner cabinet does not fall out of the A opening during installation or removal.  The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded 3prong outlet. B  It is the customer's responsibility and obligation to have this product installed by a qualified technician familiar with through-the

Summary of the content on the page No. 10

3. Use a level to check that cabinet is level side to side. 4. Check that air conditioner cabinet is tilted to the outside so that water will run to the outside. 5. Reuse the insulation to seal opening between cabinet and frame. 6. Use existing holes in sides and top of cabinet and 7 - #10 x 1" wood screws (not provided) to attach cabinet to frame. NOTE: Do not overtighten screws or cabinet will distort and A provide a poor air seal between cabinet and air conditioner. 7. Caulk all outsid

Summary of the content on the page No. 11

Position ground wire pointing straight up. Put excess ground wire between coil and air conditioner cabinet. A A B A. Green ground wire B. Ground screw 6. Push front panel straight on and then lower it slightly to lock it into place. B 7. Using the indents in top of filter door, pull door down. A. Front of unit B. 2 - #8 - 18 x ³⁄₈" round-head screws NOTE: For through-the-wall installations, if needed, install molding around room side of cabinet. WARNING A A. Indents Electrical Shock Hazard 8.

Summary of the content on the page No. 12

NOTES: Fan Speed  When the air conditioner is off, the Room indicator light is lit and the display shows the current room temperature. NOTE: The Fan Speed button will operate only when Cool, Fan  If the room temperature is below 55ºF (13ºC), the display will Only or Power Saver mode has been selected. show 55ºF (13ºC). If the room temperature is above 99ºF 1. Press FAN SPEED until you see the indicator light come on (37ºC), the display will show 99ºF (37ºC). for the setting you desire.

Summary of the content on the page No. 13

To change the temperature display from °F to °C: To see or change the remaining time (in hours): 1. Turn off the air conditioner. 1. Press TIMER once after it has been programmed. Hour indicator light will turn on, and display will show remaining 2. While the air conditioner is off, press and hold down the time. MODE and FAN SPEED buttons while pressing POWER to turn on the air conditioner. 2. While the display is showing the remaining time, you can press the plus or minus button to increas

Summary of the content on the page No. 14

To select the fan speed (in Cool, Fan Only or Power Saver 3. Press the plus or minus button to change delay time (1 to 24 hours). mode only): Press TURBO, HIGH or LOW. 4. Press TIMER again or wait 10 seconds. Timer indicator light on air conditioner will remain on. Hour indicator light on air conditioner will turn off, and Room indicator light on air conditioner will turn on. Display on air conditioner will show the current room temperature. To set Timer to turn on air conditioner, changin

Summary of the content on the page No. 15

Style 1—Cool only air conditioner settings Style 2—Heat/cool air conditioner settings (on some models) Fan Control Fan Control Set the Fan control to the desired setting. When the air conditioner is operating at Low Cool, High Cool or Turbo Cool, Set FAN control to the desired setting. When the air conditioner is the fan circulates air continuously. operating at Low Cool, High Cool, Turbo Cool, Low Heat or Turbo Heat, the fan circulates air continuously.  Turbo Cool—for maximum cooling  T

Summary of the content on the page No. 16

Changing Air Direction Normal Sounds Use the tabs to direct the air right, left or straight ahead (on some When your air conditioner is operating normally, you may hear models). Rotate the whole cartridge to direct air up, down or sounds such as: straight ahead.  Droplets of water hitting the condenser, causing a pinging or clicking sound. The water droplets help cool the condenser. A  Air movement from the fan.  Clicks from the thermostat cycle.  Vibrations or noise due to poor wall or wi

Summary of the content on the page No. 17

TROUBLESHOOTING Before calling for service, try the suggestions below to see whether you can solve your problem without outside help.  The air conditioner is in a heavily occupied room, or heat- Air conditioner will not operate producing appliances are in use in the room. Use exhaust vent fans while cooking or bathing and try not to use heat-  The power supply cord is unplugged. Plug into a grounded producing appliances during the hottest part of the day. A 3 prong outlet. See “Electrical Re

Summary of the content on the page No. 18

Temperature on display does not match room Water drips from cabinet into your house temperature  The air conditioner is not properly leveled. The air  When the compressor and fan motor turn off during conditioner should slope slightly downward toward the Power Saver mode, or after you turn off the unit, a lower outside. Level the air conditioner to provide a downward temperature reading than the actual room temperature slope toward the outside to ensure proper drainage. See the may be disp

Summary of the content on the page No. 19

SEGURIDAD DEL ACONDICIONADOR DE AIRE Su seguridad y la seguridad de los demás es muy importante. Hemos incluido muchos mensajes importantes de seguridad en este manual y en su electrodoméstico. Lea y obedezca siempre todos los mensajes de seguridad. Este es el símbolo de advertencia de seguridad. Este símbolo le llama la atención sobre peligros potenciales que pueden ocasionar la muerte o una lesión a usted y a los demás. Todos los mensajes de seguridad irán a continuación del símbolo de adve

Summary of the content on the page No. 20

Piezas suministradas (en algunos modelos) NOTAS: No deben obstruirse las rejillas del gabinete. El aire debe circular libremente a través de las rejillas del gabinete. Verifique que estén todas las piezas en el paquete de piezas. B C D A A E F G H I J A. Rejillas del gabinete K L Instalación en la ventana Medidas de la abertura de la ventana:  Ancho: 26¹⁄₂" (66,1 cm) mínimo a 40" (101,6 cm) máximo M N O P  Altura: 20" (50,8 cm) mínimo A. Soporte de seguridad J. Obturadores de espuma para el


Alternative user manuals
# User manual Category Download
1 Whirlpool 1163570 User manual Air Conditioner 500
2 Whirlpool 1159801 User manual Air Conditioner 40
3 Whirlpool 1187361 User manual Air Conditioner 25
4 Whirlpool 1172397 User manual Air Conditioner 22
5 Whirlpool 1328891 User manual Air Conditioner 32
6 Whirlpool 1166073 User manual Air Conditioner 25
7 Whirlpool 1188177 User manual Air Conditioner 8
8 Whirlpool 3QACM07XD2 User manual Air Conditioner 15
9 Whirlpool 4380701 User manual Air Conditioner 9
10 Whirlpool 3PACH21DD0 User manual Air Conditioner 10
11 Whirlpool 66161279 User manual Air Conditioner 7
12 Whirlpool 819041994 User manual Air Conditioner 3
13 Whirlpool AC0052 User manual Air Conditioner 12
14 Whirlpool AC1 352 User manual Air Conditioner 4
15 Whirlpool ACC602 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21