Sanyo SAP-K77RAX user manual

User manual for the device Sanyo SAP-K77RAX

Device: Sanyo SAP-K77RAX
Category: Air Conditioner
Manufacturer: Sanyo
Size: 3.91 MB
Added : 7/26/2013
Number of pages: 68
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sanyo SAP-K77RAX. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sanyo SAP-K77RAX.

For your convenience

If looking through the Sanyo SAP-K77RAX user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sanyo SAP-K77RAX on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sanyo SAP-K77RAX to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sanyo SAP-K77RAX User manual - Online PDF
Advertisement
« Page 1 of 68 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sanyo SAP-K77RAX but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sanyo SAP-K77RAX. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TECHNICAL & SERVICE MANUAL
FILE NO.
SAP-K77RAX + SAP-C77RAX
SAP-K97RAX + SAP-C97RAX
SAP-K127RAX + SAP-C127RAX
Destination: Russia (50Hz)
SPLIT SYSTEM AIR CONDITIONER
Indoor Model No. Product Code No. Outdoor Model No. Product Code No.
SAP-K77RAX 1 852 350 01 SAP-C77RAX 1 852 350 04
SAP-K97RAX 1 852 350 02 SAP-C97RAX 1 852 350 05
SAP-K127RAX 1 852 350 03 SAP-C127RAX 1 852 350 06
Indoor Unit Outdoor Unit
SAP-K77RAX SAP-C77RAX
SAP-K97RAX SAP-C97RAX
SAP-K127RAX
SAP-C127RAX
REFERENCE NO. SM700754

Summary of the content on the page No. 2

When Transporting Important! Be careful when picking up and moving the indoor and Please Read Before Starting outdoor units. Get a partner to help, and bend your knees This air conditioning system meets strict safety and when lifting to reduce strain on your back. Sharp edges or operating standards. As the installer or service person, it thin aluminum fins on the air conditioner can cut your is an important part of your job to install or service the fingers. system so it operates safely

Summary of the content on the page No. 3

Table of Contents Page 1. OPERATING RANGE ................................................................................................................... 5 2. SPECIFICATIONS 2-1. Unit Specifications ............................................................................................................. 6 2-2. Major Component Specifications ....................................................................................... 9 2-3. Other Component Specifications .....................

Summary of the content on the page No. 4

Page 9. TROUBLESHOOTING 9-1. Check before and after troubleshooting ................................................................................ 43 9-2. Air conditioner does not operate. ........................................................................................... 44 9-3. Some part of air conditioner does not operate. ..................................................................... 48 9-4. Air conditioner operates, but abnormalities are observed. .....................

Summary of the content on the page No. 5

1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 32 °C D.B. / 23 °C W.B. 43 °C D.B. Cooling Minimum 19 °C D.B. / 14 °C W.B. 19 °C D.B. 5

Summary of the content on the page No. 6

2. SPECIFICATIONS 2-1. Unit Specifications Indoor Unit SAP-K77RAX Outdoor Unit SAP-C77RAX Power Source 220 to 240V Single-Phase 50Hz Voltage Rating 220-240 V Performance Cooling Capacity kW 2.10 / 2.10 / 2.10 BTU/h 7,200 / 7,200 / 7,200 3 Air Circulation (High) m 430 /h Moisture Removal (High) Liters/h 1.1 Electrical Rating Cooling Available Voltage Range V 198 to 264 Running Amperes A 3.5 / 3.6 / 3.6 Power Input W 750 / 770 / 790 Power Factor % 97 / 93 / 91 E.E.R. W/W 2.80 / 2.73 / 2.66 C.O

Summary of the content on the page No. 7

Indoor Unit SAP-K97RAX Outdoor Unit SAP-C97RAX Power Source 220 to 240V Single-Phase 50Hz Voltage Rating 220-240 V Performance Cooling Capacity kW 2.55 / 2.55 / 2.55 BTU/h 8,700 3 Air Circulation (High) m 440 /h Moisture Removal (High) Liters/h 1.8 Electrical Rating Cooling Available Voltage Range V 198 to 264 Running Amperes A 4.5 / 4.5 / 4.6 Power Input W 930 / 960 / 1,000 Power Factor % 94 / 93 / 91 E.E.R. W/W 2.74 / 2.66 / 2.55 C.O.P. W/W - Compressor Locked Rotor Amperes A 22.5 Features C

Summary of the content on the page No. 8

Indoor Unit SAP-K127RAX Outdoor Unit SAP-C127RAX Power Source 220 to 240V Single-Phase 50Hz Voltage Rating 220-240 V Performance Cooling Capacity kW 3.55 / 3.55 / 3.55 BTU/h 12,100 / 12,100 / 12,100 3 Air Circulation (High) m 460 /h Moisture Removal (High) Liters/h 2.5 Electrical Rating Cooling Available Voltage Range V 198 to 264 Running Amperes A 6.1 / 6.1 / 6.2 Power Input W 1,265 / 1,305 / 1,345 Power Factor % 94 / 93 / 90 E.E.R. W/W 2.81 / 2.72 / 2.64 C.O.P. W/W - Compressor Locked Rotor A

Summary of the content on the page No. 9

2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor Unit SAP-K77RAX Control PCB Part No. CR-K77GAX Controls Microprocessor Control Circuit Fuse 250V 3.15A Remote Control Unit RCS-7S2E-G Fan Type Cross-Flow Q'ty ... Dia. and Length mm 1 ... D102 / L637 Fan Motor Type AC Motor Model ... Q'ty IBH-884-066B ... 1 No. of Poles 4 Rough Measure RPM (Cool) 1,280 Nominal Output W 12.5 Coil Resistance Ohm BRN-WHT : 234 (Ambient Temp. 20 °C) PNK (RED)-WHT : 209 Safety Device Type Thermal fuse

Summary of the content on the page No. 10

Indoor Unit SAP-K97RAX Control PCB Part No. CR-K97GAX Controls Microprocessor Control Circuit Fuse 250V 3.15A Remote Control Unit RCS-7S2E-G Fan Type Cross-Flow Q'ty ... Dia. and Length mm 1 ... D102 / L637 Fan Motor Type AC Motor Model ... Q'ty IBH-884-066B ... 1 No. of Poles 4 Rough Measure RPM (Cool) 1,290 Nominal Output W 12.5 Coil Resistance Ohm BRN-WHT : 234 (Ambient Temp. 20 °C) PNK (RED)-WHT : 209 Safety Device Type Thermal fuse Operating Temp. Open °C 130 Close - Run Capacitor (on con

Summary of the content on the page No. 11

Indoor Unit SAP-K127RAX Control PCB Part No. CR-K127GAX Controls Microprocessor Control Circuit Fuse 250V 3.15A Remote Control Unit RCS-7S2E-G Fan Type Cross-Flow Q'ty ... Dia. and Length mm 1 ... D102 / L637 Fan Motor Type AC Motor Model ... Q'ty IBH-884-066B ... 1 No. of Poles 4 Rough Measure RPM (Cool) 1,300 Nominal Output W 12.5 Coil Resistance Ohm BRN-WHT : 234 (Ambient Temp. 20 °C) PNK (RED)-WHT : 209 Safety Device Type Thermal fuse Operating Temp. Open °C 130 Close - Run Capacitor (on c

Summary of the content on the page No. 12

2-2-2. Outdoor Unit Outdoor Unit SAP-C77RAX Control PCB Compressor Type Single Rotary Compressor Model / Nominal Output C-1R65H5S / 650W Compressor Oil ... Amount CC SAY-56T ... 350 Ohm C - R : 4.68 Coil Resistance (Ambient Temp. 25 °C) C - S : 6.77 Safety Device Type External (OLR) Overload Relay MRA99094-9201 Operating Temp. Open °C 150 +/-5 Close °C 69 +/-11 Operating Amp. (Ambient Temp. 25 °C) Trip in 6 to 16 sec. at 15A Run Capacitor Micro F 20 VAC 400 Crankcase Heater - Fan Type Propel

Summary of the content on the page No. 13

Outdoor Unit SAP-C97RAX Control PCB Compressor Type Single Rotary Compressor Model / Nominal Output C-1RV162H91AA / 800W Compressor Oil ... Amount CC SAY-56T ... 280 Ohm C - R : 3.65 Coil Resistance (Ambient Temp. 25 °C) C - S : 5.38 Safety Device Type External (OLR) Overload Relay MRA99134-9201 Operating Temp. Open °C 145 +/- 5 Close °C 69 +/- 11 Operating Amp. (Ambient Temp. 25 °C) Trip in 6 to 16 sec. at 16.5A Run Capacitor Micro F 25 VAC 400 Crankcase Heater - Fan Type Propeller Q'ty ...

Summary of the content on the page No. 14

Outdoor Unit SAP-C127RAX Control PCB Compressor Type Single Rotary Compressor Model / Nominal Output C-R115H5A / 1,100W Compressor Oil ... Amount CC SAY-56T ... 520 Ohm C - R : 1.962 Coil Resistance (Ambient Temp. 25 °C) C - S : 5.38 Safety Device Type External (OLR) Overload Relay MRA98619-9200 Operating Temp. Open °C 150 +/- 5 Close °C 69 +/- 11 Operating Amp. (Ambient Temp. 25 °C) Trip in 6 to 16 sec. at 22.5A Run Capacitor Micro F 25 VAC 400 Crankcase Heater - Fan Type Propeller Q'ty ...

Summary of the content on the page No. 15

2-3. Other Component Specifications Indoor Unit SAP-K77RAX SAP-K97RAX SAP-K127RAX < Thermistor (Room sensor) > Model PTN-41G-S6Z Resistance 5 kohm (at 25 °C) < Thermistor (Coil sensor) > Model PB2M-41E-S16-1 Resistance 15 kohm (at 0 °C) 5.4 kohm (at 25 °C) Outdoor Unit SAP-C77RAX SAP-C97RAX SAP-C127RAX < Power Relay > Model EL200/240A1-F (M) Rating AC277V 30A 15

Summary of the content on the page No. 16

3. DIMENSIONAL DATA Indoor Unit SAP-K77RAX SAP-K97RAX SAP-K127RAX 16

Summary of the content on the page No. 17

Outdoor Unit SAP-C77RAX SAP-C97RAX 482 78 11 372 Wide tube service valve dia.9.52(3/8") Narrow tube service valve 660 60 dia.6.35(1/4") 27 127 Unit: mm 17 ID:18 44 240 14 446 264 296 87 47

Summary of the content on the page No. 18

Outdoor Unit SAP-C127RAX 11 482 78 370 Wide tube service valve dia.12.7(1/2") Narrow tube service valve 660 60 dia.6.35(1/4") 27 127 Unit: mm 18 ID:18 45 240 14 510 264 296 87 47

Summary of the content on the page No. 19

4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram Indoor Unit SAP-K77RAX Outdoor Unit SAP-C77RAX SAP-K97RAX SAP-C97RAX SAP-K127RAX SAP-C127RAX Indoor unit Outdoor unit Wide tube service Compressor Wide tube valve Accumulator *1 Narrow tube service valve Narrow tube Capillary tube Cooling cycle O.D. 6.35 mm (1/4") ... *1 O.D. 9.52 mm (3/8") 77, 97 class ... O.D. 12.7 mm (1/2") 127 class Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both

Summary of the content on the page No. 20

5. PERFORMANCE DATA 5-1. Performance charts Indoor Unit SAP-K77RAX Outdoor Unit SAP-C77RAX < Cooling Characteristics > 9 Indoor inlet air 8 D.B. temp. (°C) 7 6 5 32 27 4 21 3 2 1 25 30 35 40 45 50 Outdoor inlet air D.B. temp. ( °C) 1.47 Indoor inlet air 1.38 D.B. temp. (°C) 1.28 1.18 1.08 0.98 0.89 32 27 0.79 21 0.69 0.59 0.49 0.39 25 30 35 40 45 50 Outdoor inlet air D.B. temp. ( °C) NOTE :Points of rating condition Black dots in above charts indicate the following rating conditions. Co


Alternative user manuals
# User manual Category Download
1 Sanyo 000-24 User manual Air Conditioner 1135
2 Sanyo 09KLS51 User manual Air Conditioner 370
3 Sanyo 09KLS71 User manual Air Conditioner 160
4 Sanyo 000-31 User manual Air Conditioner 76
5 Sanyo 09KS51 User manual Air Conditioner 136
6 Sanyo 09KS71 User manual Air Conditioner 23
7 Sanyo 12KLS51 User manual Air Conditioner 22
8 Sanyo 12KS71 User manual Air Conditioner 18
9 Sanyo 12KLS71 User manual Air Conditioner 8
10 Sanyo 09KHS71 User manual Air Conditioner 22
11 Sanyo 12KS51 User manual Air Conditioner 14
12 Sanyo 12KHS32 User manual Air Conditioner 29
13 Sanyo 12RLS11 User manual Air Conditioner 10
14 Sanyo 12KHS71 User manual Air Conditioner 13
15 Sanyo 12XLS71 User manual Air Conditioner 9
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21