Summary of the content on the page No. 2
WARNING TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. ALSO, DO NOT USE THIS UNIT’S POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS UNLESS THE PRONGS CAN BE FULLY INSERTED. REFRAIN FROM OPENING THE CABINET AS THERE ARE HIGH VOLTAGE COMPONENTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION RISK OF ELECTRIC SHOCK • DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS IN
Summary of the content on the page No. 3
For the Customer to use in U.S.A. or Canada Canadian Department of Communications Compliance Statement DOC: This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouiller du Canada. C-UL: Bears the C-UL Mark and is in compliance with Canadian Safety Regulations according to CSA C22.2 No. 60950. Ce produit porte la marque ‘C-UL’ et se confor
Summary of the content on the page No. 4
Contents Your new NEC AccuSync LCD monitor box* should contain the following: • AccuSync LCD monitor with tilt base • Audio Cable • Power Cord • Video Signal Cable • User’s Manual • CD-ROM CD-ROM User’s Manual Audio Cable Power Cord Video Signal Cable Base Stand AccuSync LCD monitor (base stand not connected) * Remember to save your original box and packing material to transport or ship the monitor. Quick Start To attach the Base to the LCD Stand: 1. Insert the front of the LCD stand into the ho
Summary of the content on the page No. 5
3. Connect the 15-pin mini D-SUB of the video signal cable, Audio Cable and Headphone (not included) to the appropriate connector on the back of the monitor (Figure B.1). 4. Connect one end of the power cord to the monitor and the other end to the power outlet. Place the Video Signal Cable, Headphone (not included) and power cord to the Cable holder (Figure B.1). NOTE: Adjust position of cable that place under the Cable holder to avoid damage for cable or monitor. NOTE: If you use this monitor a
Summary of the content on the page No. 6
Non-abrasive surface Figure R.1 Figure R.2 Figure R.3 Removing the Base NOTE: Always remove the Base when shipping the LCD. 1. Place monitor face down on a non-abrasive surface (Figure R.1). 2. While using your thumbs, press the bottom tabs upward to unlock. 3. Press the top tabs down to unlock and pull off the stand. Connecting a Flexible Arm This LCD monitor is designed for use with a flexible arm. Please use the attached screws (4pcs) as show in the picture when installing. To meet the safety
Summary of the content on the page No. 7
Controls OSM (On-Screen Manager) control buttons on the front of the monitor function as follows: 1. Basic function at pressing each key SELECT AUTO / RESET – + Button At No OSD Shortcut to Bright adjust Shortcut to Volume adjust “Auto adjust” operate. Showing OSM. showing window. window. At OSD showing Go to Adjustment stage. Cursor goes to left. Cursor goes to right. (Icon selection stage) At OSD showing Go to Icon selection stage. Adjust value decrease or Adjust value increase or Reset operat
Summary of the content on the page No. 8
AUDIO Audio volume icon is chosen, depending on the volume condition (AUTO/RESET). BRIGHTNESS Adjusts the overall image and background screen brightness. CONTRAST Adjusts the image brightness in relation to the background. AUTO CONTRAST Adjusts the image displayed for non-standard video inputs. AUTO ADJUST Automatically adjusts the Image Position, the H. Size and Fine setting. LEFT/RIGHT Controls Horizontal Image Position within the display area of the LCD. DOWN/UP Controls Vertical Image Positi
Summary of the content on the page No. 9
OSM LOCK OUT This control completely locks out access to all OSM control functions without Brightness and Contrast. When attempting to activate OSM controls while in the Lock Out mode, a screen will appear indicating the OSM are locked out. To activate the OSM Lock Out function, press “AUTO/ RESET”, then “+” key and hold down simultaneously. To de-activate the OSM Lock Out, press “AUTO/ RESET”, then “+” key and hold down simultaneously. RESOLUTION NOTIFIER If ON is selected, a message will appea
Summary of the content on the page No. 10
Recommended use Safety Precautions and Maintenance FOR OPTIMUM PERFORMANCE, PLEASE NOTE THE FOLLOWING WHEN SETTING UP AND USING THE ACCUSYNC LCD COLOUR MONITOR: • DO NOT OPEN THE MONITOR. There are no user serviceable parts inside and opening or removing covers may expose you to dangerous shock hazards or other risks. Refer all servicing to qualified service personnel. • Do not spill any liquids into the cabinet or use your monitor near water. • Do not insert objects of any kind into the cabinet
Summary of the content on the page No. 11
CORRECT PLACEMENT AND ADJUSTMENT OF THE MONITOR CAN REDUCE EYE, SHOULDER AND NECK FATIGUE. CHECK THE FOLLOWING WHEN YOU POSITION THE MONITOR: • For optimum performance, allow 20 minutes for warm-up. • Adjust the monitor height so that the top of the screen is at or slightly below eye level. Your eyes should look slightly downward when viewing the middle of the screen. • Position your monitor no closer than 40 cm and no further away than 70 cm from your eyes. The optimal distance is 58 cm. • Rest
Summary of the content on the page No. 12
Specifications LCD51VM Monitor Monitor Specifications AccuSync LCD51VM Monitor Notes LCD Module Diagonal: 38.1 cm/15 inches Active matrix; thin film transistor (TFT) Viewable Image Size: 38.1 cm/15 inches liquid crystal display (LCD); 0.297 mm dot 2 Native Resolution (Pixel Count): 1024 x 768 pitch; 250 cd/m white luminance, 400/ 450:1 contrast ratio, typical. Input Signal Video: ANALOG 0.7 Vp-p/75 Ohms Sync: Separate sync.TTL Level (Positive/Negative) Horizontal sync. Positive/Negative Vertical
Summary of the content on the page No. 13
Specifications LCD71VM Monitor Monitor Specifications AccuSync LCD71VM Monitor Notes LCD Module Diagonal: 43.2 cm/17 inches Active matrix; thin film transistor (TFT) Viewable Image Size: 43.2 cm/17 inches liquid crystal display (LCD); 0.264 mm dot 2 Native Resolution (Pixel Count): 1280 x 1024 pitch; 250 cd/m white luminance, 450:1 contrast ratio, typical. Input Signal Video: ANALOG 0.7 Vp-p/75 Ohms Sync: Separate sync.TTL Level (Positive/Negative) Horizontal sync. Positive/Negative Vertical syn
Summary of the content on the page No. 14
Features Reduced Footprint: Provides the ideal solution for environments requiring superior image quality but with size and weight limitations. The small footprint and low weight allow it to be moved or transported easily from one location to another. AccuColor Control Systems: Allows you to adjust the colours on your screen and customize the colour accuracy of your monitor to a variety of standards. OSM (On-Screen Manager) Controls: Allow you to quickly and easily adjust all elements of your sc
Summary of the content on the page No. 15
Troubleshooting No picture • The signal cable should be completely connected to the display card/computer. • The display card should be completely seated in its slot. • Check front power Switch and computer power switch should be in the ON position. • Check to make sure that a supported mode has been selected on the display card or system being used. (Please consult display card or system manual to change graphics mode.) • Check the monitor and your display card with respect to compatibility and
Summary of the content on the page No. 16
TCO’99 Congratulations! You have just purchased a Lead** TCO’99 approved and labelled product! Your Lead can be found in picture tubes, display screens, solders and choice has provided you with a product developed capacitors. Lead damages the nervous system and in higher for professional use. Your purchase has also doses, causes lead poisoning. contributed to reducing the burden on the TCO’99 requirement permits the inclusion of lead since no environment and also to the further development repla