Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA user manual

User manual for the device Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA

Device: Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA
Category: Air Conditioner
Manufacturer: Mitsubishi Electronics
Size: 2.84 MB
Added : 6/24/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA.

For your convenience

If looking through the Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Mitsubishi Electronics Mitsubishi Digital ElectronicsMSZ-FD09NA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Revision A:
• 3. SPECIFICATION has been corrected.
Please void OBH497.
INDOOR UNIT
No. OBH497
REVISED EDITION-A
SERVICE MANUAL
Wireless type
Models
MSZ-FD09NA
MSZ-FD12NA
Outdoor unit service manual
MUZ-FD•NA Series (OBH498)
MXZ-A·NA Series (OB444)
CONTENTS
1. TECHNICAL CHANGES······································· 3
2. PART NAMES AND FUNCTIONS ····················· 4
3. SPECIFICATION ················································ 5
4. OUTLINES AND DIMENSIONS ························ 7
5. W

Summary of the content on the page No. 2

Revision A: • 3. SPECIFICATION has been corrected. 2

Summary of the content on the page No. 3

1 TECHNICAL CHANGES MSZ-FD09NA MSZ-FD12NA 1. New model. 3

Summary of the content on the page No. 4

2 PART NAMES AND FUNCTIONS MSZ-FD09NA MSZ-FD12NA AREA lamp POWER lamp Remote control Operation indicator receiving section lamp Front panel Airfilter Air inlet Remote controller Platinum deodorizing filter Anti-allergy Enzyme Filter i-see Sensor Air outlet Emergency operation switch Fan Horizontal vane Heat exchanger AREA lamp indicates AREA setting i-see control operation In AREA setting, the horizontal air flow i-see Sensor constantly measure direction changes automatically floor/wall temp

Summary of the content on the page No. 5

3 SPECIFICATION Indoor model MSZ-FD09NA MSZ-FD12NA Power supply V, phase, Hz 208/230 , 1 , 60 Max. fuse size (time delay)/ Disconnect switchA15 Min. circuit ampacity A 1.0 1.0 Fan motor F.L.A 0.76 HEAT Dry CFM 166 - 240 - 381 166 - 240 - 420 Airfl ow COOL Dry 162 - 226 - 339 162 - 226 - 381 Low - Med. - High CFM (Wet) (144 - 202 - 307) (144 - 202 - 350) Moisture removal pt./h 2.1 2.9 Cooling dB(A) 22 - 31 - 39 22 - 33 - 43 Sound level Low - Med. - High Heating dB(A) 22 - 31 - 40 22 - 33 - 43 Co

Summary of the content on the page No. 6

3-1. OPERATING RANGE (1) POWER SUPPLY Rated voltage Guaranteed Voltage Min.187 V 208 V 230 V Max.253 V 208/230 V Indoor unit 1 phase 60 Hz (2) OPERATION Intake air temperature (°F) Mode Condition Indoor Outdoor DB WB DB WB Standard temperature 80 67 95 — Maximum temperature 90 73 115 — Cooling Minimum temperature 67 57 14 — Maximum humidity 78 % — Standard temperature 70 60 47 43 Heating Maximum temperature 80 67 75 65 Minimum temperature 70 60 14 13 3-2. OUTLET AIR SPEED AND COVERAGE RA

Summary of the content on the page No. 7

4 OUTLINES AND DIMENSIONS Unit : inch MSZ-FD09NA MSZ-FD12NA 7/16 X 1 Oblong hole 7/16 X 13/16 Oblong hole 8-7/8 8-7/8 2-1/2 2-1/2 Installation plate 31-3/8 30-7/8 1/2 6-1/8 6-1/8 2-1/8 13-9/16 13 2-11/16 Indoor unit Wall hole ø2-9/16 Air in Installation plate 10-1/8 1/4 Piping 2-3/16 27-1/16 2-3/16 Drain hose 1-11/16 1-11/16 3-3/8 3-13/16 2-5/16 3/4 Air out Insulation ø1-3/8 O.D Liquid line ø1/4 19-11/16 (Flared connection ø1/4) Gas line ø3/8 16-15/16 (Flared connection ø3/8) Drain hose Insul

Summary of the content on the page No. 8

5 WIRING DIAGRAM MSZ-FD09NA MSZ-FD12NA 8

Summary of the content on the page No. 9

6 REFRIGERANT SYSTEM DIAGRAM Unit:inch MSZ-FD09NA MSZ-FD12NA Refrigerant pipe 3/8 (with heat insulator) Indoor coil Indoor thermistor heat RT12 (main) exchanger Flared connection Indoor coil thermistor RT13 (sub) Room temperature thermistor RT11 Flared connection Refrigerant pipe 1/4 (with heat insulator) Refrigerant flow in cooling Refrigerant flow in heating 9

Summary of the content on the page No. 10

7 SERVICE FUNCTIONS MSZ-FD09NA MSZ-FD12NA 7-1. TIMER SHORT MODE For service, set time can be shortened by short circuit of JPG and JPS the indoor electronic control P.C. board. The time will be shortened as follows. (Refer to 9-7.) Set time : 1-minute 1-second Set time : 3-minute 3-second (It takes 3 minutes for the compressor to start operation. However, the starting time is shortened by short circuit of JPG and JPS.) 7-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION A maximum

Summary of the content on the page No. 11

7-3. AUTO RESTART FUNCTION When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed are memorized by the indoor electronic control P.C. board. “AUTO RESTART FUNCTION” automatically starts operation in the same mode just before the shutoff of the main power. Operation If the main power has been cut, the operation settings remain. After the power is restored, the unit restarts automatically according to the memory. (However, i

Summary of the content on the page No. 12

8 MICROPROCESSOR CONTROL MSZ-FD09NA MSZ-FD12NA WIRELESS REMOTE CONTROLLER Signal transmitting section Operation display section VANE CONTROL button OPERATE/STOP FAN SPEED CONTROL button (ON/OFF) button OFF TIMER button OPERATION SELECT button ON TIMER button POWERFUL button TIME SET buttons Temperature buttons FORWARD button BACKWARD button WIDE VANE button i-see button (Vertical vane button) AREA button CLOCK SET button RESET button Indication of remote controller model is on back NOTE: Last

Summary of the content on the page No. 13

8-1. COOL ( ) OPERATION (1) Press OPERATE/STOP (ON/OFF) button. POWER lamp of the indoor unit turns on with a beep tone. (2) Select COOL mode with OPERATION SELECT button. (3) Press TEMPERATURE buttons (TOO WARM or TOO COOL button) to select the desired temperature. The setting range is 61 ~ 88°F (16 ~ 31°C). 1. Coil frost prevention The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the coil from frosting. When the temperature of

Summary of the content on the page No. 14

8-4. AUTO CHANGE OVER ··· AUTO MODE OPERATION Once desired temperature is set, unit operation is switched automatically between COOL and HEAT operation. Mode selection (1) Initial mode When unit starts the operation with AUTO operation from off; • If the room temperature is higher than the set temperature, operation starts in COOL mode. • If the room temperature is equal to or lower than the set temperature, operation starts in HEAT mode. (2) Mode change COOL mode changes to HEAT mode when abo

Summary of the content on the page No. 15

(3) Positioning To confirm the standard position, the vane moves until it touches the vane stopper. Then the vane is set to the selected angle. Confirming of standard position is performed in the following cases: (a) The operation starts or finishes (including timer operation). (b) The test run operation starts. (c) Standby mode (only during multi system operation) starts or finishes. (4) VANE AUTO ( ) mode The microprocessor automatically determines the vane angle to make the optimum room tem

Summary of the content on the page No. 16

(10) POWERFUL ( ) operation. The air conditioner automatically adjusts the fan speed and the set temperature, and operates the POWERFUL mode. The POWERFUL mode is automatically released 15 minutes after operation starts, and the operation mode returns to the mode prior to POWERFUL operation 2. Vertical vane (1) Vane motor drive These models are equipped with a stepping motor for the vertical vane. The rotating direction, speed, and angle of the motor are controlled by pulse signals (approx.

Summary of the content on the page No. 17

8-6. i-see CONTROL OPERATION The sensors constantly measure the room and floor/wall temperatures to automatically adjust to the set temperature by esti- mating the temperature actually perceived by a person inside the room (“sensory temperature”). Advantages · The air inside the room is conditioned quickly to a comfortable condition. · The room will not become too cold or hot even when the air conditioner is kept on for a long period. · The air conditioner will not overcool or overheat, which me

Summary of the content on the page No. 18

Indoor unit installation location and air-conditioning area Installed at left Installed at center Installed at right LEFT RIGHT LEFT RIGHT LEFT RIGHT ·Be sure to set the slide switch inside the remote controller to an appropriate position in accordance with the installed position of the indoor unit. If the switch is not set correctly, the air conditioner may not function properly. (Refer to "Remote controller in SERVICE FUNCTIONS".) To air-condition mainly To air-condition the entire room To air

Summary of the content on the page No. 19

Operation and operating range i-see sensor moves 30 degrees from the center in both right and left side. i-see Sensor turning to the center i-see Sensor turning to the right i-see Sensor turning to the left i-see Sensor operates as follows in accordance with AREA setting made with the remote controller. “AUTO” in AREA setting; first turning to the LEFT for adjusting the position then ····· CENTER RIGHT CENTER LEFT CENTER ····· (The sensor turns to

Summary of the content on the page No. 20

8-8. TIMER OPERATION 1. How to set the time (1) Check that the current time is set correctly. NOTE : Timer operation will not work without setting the current time. Initially “0:00 AM” blinks at the current time dis- play of TIME MONITOR, so set the current time correctly with CLOCK SET button. How to set the current time (a) Press the CLOCK set button. (b) Press the TIME SET buttons ( and ) to set the current time. • Each time FORWARD button ( ) is pressed, the set time increases by 1 minu


Alternative user manuals
# User manual Category Download
1 Mitsubishi Electronics 15 User manual Air Conditioner 120
2 Mitsubishi Electronics 20-L User manual Air Conditioner 11
3 Mitsubishi Electronics 2.5KKC User manual Air Conditioner 14
4 Mitsubishi Electronics 20-MYA User manual Air Conditioner 16
5 Mitsubishi Electronics 8 User manual Air Conditioner 3
6 Mitsubishi Electronics A18AR User manual Air Conditioner 4
7 Mitsubishi Electronics CITY MULTI PKFY-PVAM-A User manual Air Conditioner 43
8 Mitsubishi Electronics CMB-P-V-F User manual Air Conditioner 12
9 Mitsubishi Electronics CITY MULTI PUHY-YMC User manual Air Conditioner 227
10 Mitsubishi Electronics A12 User manual Air Conditioner 27
11 Mitsubishi Electronics LOSSNAY LGH-100RX4-E User manual Air Conditioner 45
12 Mitsubishi Electronics LOSSNAY LGH-150RX4-E User manual Air Conditioner 18
13 Mitsubishi Electronics G-50A User manual Air Conditioner 458
14 Mitsubishi Electronics 20 PRH-5 User manual Air Conditioner 7
15 Mitsubishi Electronics LOSSNAY LGH-200RX4-E User manual Air Conditioner 16
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21