Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS user manual

User manual for the device Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS

Device: Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS
Category: Air Conditioner
Manufacturer: Friedrich
Size: 0.52 MB
Added : 8/19/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS.

For your convenience

If looking through the Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich WallMaster PACKAGED TERMINAL S AND HEAT PUMPS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INCREDIBLE!
12.2 EER
PTAC
AMERICA'S BEST AIR CONDITIONER
PRODUCT PROFILE
PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS
®
The All-new Friedrich
WallMaster
®
WallMaster is a perfect fit
7,000 / 9,000 / 12,000 / 15,000 Btu/h
for:
New construction in hotels/
motels, medical facilities, assisted
living centers, apartments/condos,
office suites, dormitories and
remodels.
®
The New WallMaster retrofits
into existing 16" x 42" sleeves
more easily than other
manufacturer's PTACs.
Standard Features
!

Summary of the content on the page No. 2

PE Series Chassis Specifications MODELS: PE07K PE07R PE09K PE09R PE12K PE12R PE15K PE15R PERFORMANCE DA T A : Cooling Btuh. 9200/9000 12000 15000 7500/7300 7500 9200 12000/11800 15000/14800 Cooling Power (W) 615/598 814/796 1091 1579 615 814 1091/1073 1579/1578 EER 12.2 12.2 11.3 11.0 11.0 9.5 9.5 11.3 Dehumidification (Pts/h) 2.1 2.1 2.7 3.8 3.8 5.5 5.5 2.7 Sensible Heat Ratio 0.76 0.76 0.75 0.72 0.72 0.72 0.72 0.75 ELECTRICAL DA T A : Voltage (1 Ph, 60Hz) 265 230/208 265 230/208 265 230/208 2

Summary of the content on the page No. 3

Extended Cooling Performance, PE07/09/12/15 Outdoor Dry Bulb Temp. (°F at 40% R.H.) 75 85 95 105 115 Indoor Wet Bulb Temp. (°F at 80°F D.B.) 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 Btuh 8820 8483 7853 8400 7920 7305 8070 7500 6638 7560 6713 5918 6728 5790 5115 502 510 515 547 552 559 615 615 615 665 664 666 725 725 728 Watts PE07 2.5 2.5 2.5 2.7 2.7 2.7 3 3.00 3 3.2 3.2 3.2 3.5 3.5 3.5 Amps 0.52 0.71 0.95 0.53 0.73 0.97 0.53 0.76 0.98 0.55 0.8 0.98 0.57 0.86 0.97 SHR 10819 10405 9632 10304

Summary of the content on the page No. 4

Electric Heat Data, PE/PH 07/09K/R MODELS: PE/PH07K PE/PH07R PE/PH09K PE/PH09R PERFORMANCE DATA: 3400 Heater Watts 2500/2050 3400/2780 2500 3400 2500/2050 3400/2780 5000/4090 2500 5000 Voltage 230/208 265 230/208 265 Heating Btuh 8500 11600 11600/9500 11600 17000 8500/7000 11600/9500 8500/7000 17000/13900 8500 Heating Power (Watts) 3490 3500/2880 3490 2600/2150 3500/2880 2590 2600/2150 5210/4300 2590 5210 Heating Current (Amps) 13.2 11.4/10.4 15.3/13.9 9.8 13.2 11.4/10.4 15.3/13.9 22.3/20.3 9.8

Summary of the content on the page No. 5

13 ¾" Typical Wall Sleeve Installation (PXWS) Electrical Receptacle Lintel Used To Support 16¼" Masonry Walls Insulation 50"Max Electrical Receptacle Main Studs Lintel Installation Lintel Installation Lintel Installation Lintel Installation Lintel Installation Jack Smooth side of clip on Room side Stud Note the use of a lintel under the first course of bricks above the wall sleeve. Do not use the wall sleeve as a lintel. The mounting screw holes shown are to be made by the installer. No holes

Summary of the content on the page No. 6

Internal Drain Kit Location and Installation (PXDR10) Primary Area: Condensation from the chassis collects in the Wall Sleeve Bottom sleeve in this area. The Foam Gasket Primary Area is the Mounting Plate Tube preferred installation PXDR10 DRAIN KIT Screw Screw location. 1/2" O.D. Tube Mounting Plate Gasket External Drain When using an external drain system, the condensate is removed through either of two drain holes on the back of the wall sleeve. Select the drain hole which best meets your

Summary of the content on the page No. 7

® WallMaster PTAC/PTHP Engineering Specifications All units shall be factory assembled, piped, wired and fully charged with R-22. All units shall be certified in accordance with ARI Standard 310 for air conditioners and ARI Standard 380 for heat pumps. Units shall be UL listed and carry a UL label. All units shall be factory run-tested to check operation and be Friedrich WallMaster® or equivalent. The basic unit shall not exceed 16" high x 42" wide. Overall depth of the unit from the rear of

Summary of the content on the page No. 8

Friedrich PTAC Accessories New Construction Accessories MODEL NUMBER DESCRIPTION PHOTO WALL SLEEVE G-90 zinc coated steel is prepared in an eleven-step process, then powder coated for maximum coverage and protection. The wall sleeve is insulated for thermal efficiency. 16" High PXWS x 42" Wide x 13¾" Deep. PXWS GRILLE Standard, stamped aluminum, anodized PXGA to resist chalking and oxidation. ARCHITECTURAL GRILLES Consist of heavy- PXAA gauge 6063-T5 aluminum alloy: – Clear, extruded aluminum

Summary of the content on the page No. 9

New Construction Accessories (Continued) MODEL NUMBER DESCRIPTION PHOTO DESK CONTROL KIT A field installed kit which allows the unit to be turned on or off from a remote PXDC central station via a 24V interface. This kit is compatable with all chassis models. PXDC DIGITAL REMOTE THERMOSTAT A Honeywell wall mounted remote thermostat. Compatable only RT1 RT1 with "RT" suffix chassis. Additional Accessories MODEL NUMBER DESCRIPTION PHOTO SLEEVE EXTENSION RETROFIT KIT G-90 zinc coated steel, 2¼"

Summary of the content on the page No. 10

® Friedrich WallMaster P-Series Packaged Terminal Air Conditioners Limited Warranty FRIEDRICH AIR CONDITIONING CO. Post Office Box 1540 · San Antonio, Texas 78295-1540 (210) 357-4400 · FAX (210) 357-4480 SAVE THIS CERTIFICATE. It gives you specific rights, you may also have other rights which may vary from state to state and province to province. In the event that your unit needs servicing, contact your nearest authorized service center. If you do not know the nearest service center, ask the c

Summary of the content on the page No. 11

® WALLMASTER P-SERIES PACKAGED TERMINAL AIR CONDITIONERS Purchaser: P.O. # Date: Project: Location: Engineer: Architect: Submitted By: For Approval: For Reference: ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL ACCESSORIES PXWS Qty PXDR10 Qty Wall Sleeve Condensate Drain Kit (pkg/10) Qty PXSB Qty PXWE Deep Wall Extension Subbase Qty PXDS Qty PXGA Standard Outdoor Louver Power Disconnect Switch PXAA Qty PXCJ Qty Architectural Louver, clear Conduit Kit w/Junction Box PXDB Q

Summary of the content on the page No. 12

Multiple solutions. One trusted name. Friedrich Air Conditioning Co. Post Office Box 1540 · San Antonio, Texas 78295-1540 4200 N. Pan Am Expressway · San Antonio, Texas 78218-5212 (210) 357-4400 · FAX (210) 357-4480 www.friedrich.com Printed in the U.S.A. PTACBW02 (04/02) 12


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21