Fluke VICTOREEN 05-437 user manual

User manual for the device Fluke VICTOREEN 05-437

Device: Fluke VICTOREEN 05-437
Category: Computer Monitor
Manufacturer: Fluke
Size: 1.3 MB
Added : 6/19/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fluke VICTOREEN 05-437. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fluke VICTOREEN 05-437.

For your convenience

If looking through the Fluke VICTOREEN 05-437 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fluke VICTOREEN 05-437 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fluke VICTOREEN 05-437 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fluke VICTOREEN 05-437 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fluke VICTOREEN 05-437 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fluke VICTOREEN 05-437. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1





®
Victoreen 05-437
®
Primalert 35 Area Radiation Monitor








Operators Manual





















March 2005
Manual No. 126011 Rev. 3
©2003, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies

Summary of the content on the page No. 2

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com/rms

Summary of the content on the page No. 3

Table of Contents Section 1: Introduction................................................................................................ 1-1 1.1 Product Description ..................................................................................... 1-1 1.2 Specifications............................................................................................... 1-2 Section 2: Getting Started...........................................................................................

Summary of the content on the page No. 4

(Blank page)

Summary of the content on the page No. 5

Introduction 1 Product Description Section 1 Introduction 1.1 Product Description The Primalert® 35 Area Radiation Monitor provides reliable, continuous monitoring of radioactive materials. Six front panel, color-coded LED's (1, 2, 4, 8,16, and 32 mR/h) indicate an increase or decrease in radiation level. The LED for each level lights as the radiation reaches that level and goes out as the radiation drops below that level. Visual and aural alarms are user-set to activate at anyone of

Summary of the content on the page No. 6

Victoreen 05-437 Operators Manual 1.2 Specifications Detector Energy-compensated G-M tube 137 Energy Dependence 10% to 40% from 50 KeV to 2 MeV, as referenced to Cs Overload Protection Alarms in fields higher than 100 R/h when detector is completely blocked for pulse operation. Operation Indicator Provide continuous visual indication of background radiation. Range/lndicators 1 mR/h: Green 2 mR/h: Green 4 mR/h: Yellow 8 mR/h: Yellow 16 mR/h: Red 32 mR/h: Re

Summary of the content on the page No. 7

Introduction 1 Specifications Input 230 VAC, 50 Hz, 13.8 W Output 12 VDC, 580 mA Part 14-417, Part 14-416 (Australia) Dimensions 5.9 in. high x 3.4 in. wide x 13 in thick Unit clips to wall with removable mounting clip. Accessories Supplied Appropriate 115V (230) CE approved converter P/N 102007: Wall Mounting Bracket P/N 74: Spare Lamp Available: P/N 05-441: PrimaPak™ II Backup Battery Pack P/N 05-434: Primalarm™ Remote Alarm unit. 137 P/N 62-103: Check-source,

Summary of the content on the page No. 8

Victoreen 05-437 Operators Manual (Blank page)

Summary of the content on the page No. 9

Getting Started 2 Receiving Inspection Section 2 Getting Started 2.1 Receiving Inspection Upon receipt of the unit: 1. Inspect the carton(s) and contents for damage. If damage is evident, file a claim with the carrier and notify Fluke Biomedical, Radiation Management Services at 440.248.9300. 2. Remove the contents from the packing material. 3. Verify that all items listed on the packing list have been received and are in good condition. NOTE If any of the listed items are miss

Summary of the content on the page No. 10

Victoreen 05-437 Operators Manual 2.4 Optional Power The Primapak II storage battery supplies a source of 12-16 Volt DC power to the Primalert using the converter plug connection. The plug is a Switchcraft #760, or equivalent, with the sleeve negative and pin positive. The current drain at background radiation levels is about 25 mA, and about 250 mA at full alarm levels. The optional Primapak II Back-up Battery Pack, Model No. 05-441, is available as an optional power source for the Pr

Summary of the content on the page No. 11

Operation 3 Set Up Section 3 Operation 3.1 Set Up The only set-up required for the Primalarm is the attachment of one end of the power cord (converter) to the unit and the other end into a properly grounded AC outlet as noted in Section 2. When power is first applied to the unit, the alarm and one or more of the LED's may light. After a maximum of three seconds, the indicators will extinguish and the alarm will reset. The unit should now be operational with the OPERATION INDICATOR LED

Summary of the content on the page No. 12

Victoreen 05-437 Operators Manual (Blank page)

Summary of the content on the page No. 13

Maintenance 4 Maintenance Section 4 Maintenance 4.1 Maintenance WARNING This instrument contains CMOS integrated circuits. No service should ever be attempted unless by a qualified service technician thoroughly familiar with these devices. Static charges normally present in a dry atmosphere or leakage current in soldering irons or other non-grounded tools can instantly destroy CMOS integrated devices. If this device has I.C. sockets, do not even attempt to remove or replace th

Summary of the content on the page No. 14

Victoreen 05-437 Operators Manual Table 4-2. PC Board Assembly (126021) Parts List Item No. Ref. No. Part No. Description Qty 6 V1 010054 Tube Shield Assembly 1 7 U1, 4 630001 IC, Quad Nor Gate, 4001 UB 2 IC, Quad Nand Gate, 4011 8 U7 630002 1 UB 9 U5, 6 630006 IC, Quad Latch, 4043B 2 IC, 12 Stage Counter, 10 U2, 3 630008 2 4040BE 12 D1 600005 Diode 1N5243B 1 13 D2, 3,4 600001 Diode 1N4006RL 3 14 D5, 6 600003 Diode1N414B 2 15 Q1, 2 620001 Transistor 2N4124 2 16 Q4-9 620003 Tr

Summary of the content on the page No. 15

Maintenance 4 Maintenance Resistor, Film, 200k, .25W, 46 R22, 23 302041 2 5% R20, 26,30, Resistor, Film, 100k, .25W, 47 341041 6 32,33,38, 5% Resistor, Film, 10k, .25W, 49 R27, 29,31, 34,40 341032 5 5% Resistor, Film, 200, .25W, 50 R13-18, 28 185-1448 7 5% 51 R24 185-2496 Resistor, Film, 2k, .25W, 5% 1 Resistor, Film, 20k, .25W, 52 R25, 41 342031 2 5% Resistor, Film, 3.3m, .25W, 53 R21, 39 303351 2 5% Trim Pot, 1M, .5w, 20%, 54 R3 391052 1 Open 55 R36 300501 Resistor,

Summary of the content on the page No. 16

Victoreen 05-437 Operators Manual Figure 4-1 Primalert 35 Assembly (126028) 4-4

Summary of the content on the page No. 17

Maintenance 4 Maintenance Figure 4-2 Primalert 35 Schematic (126015) 4-5

Summary of the content on the page No. 18

Victoreen 05-437 Operators Manual Figure 4-3 PC Assembly (126021) 4-6

Summary of the content on the page No. 19

Summary of the content on the page No. 20

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com/rms


Alternative user manuals
# User manual Category Download
1 Fluke VICTOREEN 875 User manual Computer Monitor 1
2 Fluke RPM4 User manual Computer Monitor 9
3 Fluke A20M-AF User manual Computer Monitor 1
4 Fluke 430 Series User manual Computer Monitor 56
5 Fluke A70M User manual Computer Monitor 2
6 Fluke HPMS User manual Computer Monitor 1
7 Sony BVM-L170 User manual Computer Monitor 7
8 Sony DDM-2802CNU User manual Computer Monitor 1
9 Sony BVM-D20F1U, BVM-D20F1E, BVM-D20F1A, BVM-D24E1WU, BVM-D24E1WE, BVM-D24E1WA, BVM-D32E1WU, BVM-D32E1WE, BVM-D32E1WA User manual Computer Monitor 15
10 Sony 500A3WE User manual Computer Monitor 8
11 Sony CPD-17SF2 User manual Computer Monitor 10
12 Sony AEP MODEL CPD-E200E User manual Computer Monitor 9
13 Sony CPD-G400 User manual Computer Monitor 9
14 Sony CPD-E220E User manual Computer Monitor 5
15 Sony 500A3WJ User manual Computer Monitor 3