Carrier 50XP user manual

User manual for the device Carrier 50XP

Device: Carrier 50XP
Category: Air Conditioner
Manufacturer: Carrier
Size: 1.3 MB
Added : 10/27/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier 50XP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier 50XP.

For your convenience

If looking through the Carrier 50XP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier 50XP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier 50XP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier 50XP User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier 50XP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier 50XP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

50XP
Performancet13SEER
Single---PackagedAirConditionerSystemwithPuronR
(R---410A) RefrigerantSingle andThree Phase
2to5NominalTons(Sizes024---060)
ProductData
Easy Installation
Factory--assembled package is a fully self--contained, electric
cooling unit that is prewired, pre--piped, and pre--charged for
minimum installation expense. These units are available in a
variety of standard cooling sizes with voltage options to meet
residential and light commercial requirements. Units are
lightweight a

Summary of the content on the page No. 2

Low sound ratings ensure a quiet indoor and outdoor TABLEOFCONTENTS environmentwith sound ratingsaslow as72dBA.(SeePage4.) FEATURES/BENEFITS............................. 1--2 Easy to servicecabinetsprovideeasy single--panel accessibilityto MODEL NUMBER NOMENCLATURE ................. 3 serviceable components during maintenance and installation. The basepan with integrated drain pan provides easy ground level ARICAPACITIES ................................... 4 installationwithorwithoutamountingpad

Summary of the content on the page No. 3

MODELNUMBERNOMENCLATURE --- 50XP 024 --- --- --- 3 0 --- --- 1 Options BT --- AL evap, vinyl condenser Type of Unit CC --- AL evap, CU condenser 50XP --- Single Packaged CU --- CU evap&condenser Air Conditioner TP --- Base unit with tin platedindoor coil hairpins System TV --- TPwith vinyl coatingon outdoor coil TC --- TPwith AL indoor coil &CU/CU outdoor coil N/A SeePricePagefor full listof factory options. Only usedif orderingan option Nominal CoolingCapacity 024 --- 2.0Tons 030 --- 2.5Tons 03

Summary of the content on the page No. 4

ARI*CAPACITIES CoolingCapacitiesandEfficiencies NETCOOLING UNIT50XP NOMINALTONS STANDARDCFM EER** SEER† CAPACITIES(Btuh) 024 2 770 24,000 11.0 13.2 030 2--1/2 960 29,000 11.0 13.0 036 3 1100 36,000 11.2 13.5 042 3--1/2 1450 41,000 11.2 13.0 048 4 1450 45,000 11.0 13.0 060 5 1710 57,000 11.0 13.0 LEGEND Notes: dB---SoundLevels(decibels) 1. Ratingsarenetvalues,reflectingtheeffectsof circulatingfan heat. db—Dry Bulb Ratingsarebasedon: SEER—Seasonal Energy Efficiency Ratio CoolingStandard: 80 °F (26

Summary of the content on the page No. 5

PHYSICALDATA PhysicalData--Unit50XP UNITSIZE 024 030 036 042 048 060 NOMINAL CAPACITY(ton) 2 2---1/2 3 3---1/2 4 5 SHIPPING WEIGHT(lb) 356 360 378 436 470 515 SHIPPING WEIGHT(kg) 161 163 171 198 213 234 Scroll COMPRESSORS Quantity 1 REFRIGERANT(R---410A) 7.3 8.0 9.5 10.7 11.25 13.2 Quantity (lb.) 3.3 3.6 4.3 4.9 5.1 6.0 Quantity (kg) REFRIGERANTMETERING DEVICE TXV OUTDOORCOIL Rows...Fins/in. 2...21 2...21 2...21 2...21 2...21 2...21 Face Area (sq ft) 11.95 12.0 13.6 15.4 17.4 19.3 OUTDOORFAN Nom

Summary of the content on the page No. 6

compartment. Heater sizes range from 5.0 to 20.0 kW. Theelectric OPTIONSANDACCESSORIES heaterdesign allowstheuseofasingle--pointpowersupply forthe Factory--installedoptions entireunit, resulting in lower installed costs. Coil options include Tin--Plated* indoor hairpins, copper/copper Filter Rack features easy installation, serviceability, and and vinyl--coated construction for refrigerant coils. Units are high--filtering performancefor vertical or horizontal applications. shipped standard with

Summary of the content on the page No. 7

ECONOMIZER COIL FILTER ACCESS DOOR (HORIZONTAL APPLICATION ONLY.) FILTER DO NOT REMOVE FROM DOWNFLOW DISCHARGE. REPLACEMENT ECONOMIZER PANEL HOLE FOR ECONOMIZER WIRING HARDNESS 17 13/32 11 13/32” RAINHOOD DOOR CAULK BOTTOM CORNER LATCH ANGLE OF ECONOMIZER 16 1/4” ON EACH SIDE SIDE VIEW HINGED FILTER ACCESS DOOR INSTALL FI LTER FILTER ACCESS ALUMINUM DOOR STICKER FILTER COIL ECONOMIZER BASE FLANGE ON BASE DETAIL MANUAL OUTSIDE AIR DAMPER FILTER RACK BEND FLANGE AT 90 ˚-SCREW TO DIVIDER WITH 1-

Summary of the content on the page No. 8

UNITDIMENSIONS -- 50XP024--036 A08452 8 50XP

Summary of the content on the page No. 9

UNITDIMENSIONS -- 50XP042--060 A08453 9 50XP

Summary of the content on the page No. 10

ACCESSORYROOFCURB -- 50XP024--060 HVAC unit HVAC unit base base Gask eting inner flange* Scre w Gask eting Scre w (NO TE A) (NOTE A) inner flange* *Gask eting *Gask eting outer flange outer flange Wood nailer* Wood nailer* Flashing field Flashing field supplied supplied Roofcurb* Roofcurb* Insulation (field Insulation (field supplied) supplied) Roofing mater ial Roofing mater ial field supplied field supplied Duct wo rk Duct wo rk field supplied Cant str ip Cant str ip field supplied field

Summary of the content on the page No. 11

50XPUNITSUGGESTEDRIGGING 12 (914 mm) DETAIL A 34 A07216 A08005 SMALLCABINET LARGE CABINET Unit* 024 024 030 030 036 036 042 042 048 048 060 060 Unit* lb kg lb kg lb kg lb kg lb kg lb kg Rigging Rigging 345 156 349 158 367 166 425 193 459 208 504 229 Weight Weight NOTE: Seedimensional drawingfor corner weightdistribution.Corner weightsshown on drawingarebasedon unit---only weightsanddonotincludepack- aging. SELECTIONPROCEDURE(WITHEXAMPLE) 1.Determinecoolingandheatingrequirementsat 4.Determinefan

Summary of the content on the page No. 12

12 50XP PERFORMANCEDATA 50XP024 EvaporatorAir --- CFM/BF Temp_F(_C) 800/0.026 900/0.032 1000/0.04 OutdoorAirEntering EvaporatorAir --- Ewb_F(_C) Condenser 62 63* 67 72 62 63* 67 72 62 63* 67 72 (16.7) (17.2) (19.4) (22.2) (16.7) (17.2) (19.4) (22.2) (19.7) (17.2) (19.4) (22.2) TC 24.0 24.5 26.5 29.1 24.6 25.1 27.1 29.8 25.1 25.5 27.4 30.4 75 SHC 21.9 21.3 18.7 15.4 23.5 22.8 19.8 16.1 25.0 24.2 20.8 16.7 (23.9) kW 1.7 1.7 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 TC 22.9 23.3 25.3 27.9 23.5 23.9 2

Summary of the content on the page No. 13

13 PERFORMANCEDATA(CONT) 50XP036 EvaporatorAir --- CFM/BF Temp_F(_C)Outdoor 1100/0.06 1225/0.07 1400/0.08 AirEntering EvaporatorAir --- Ewb_F(_C) Condenser 62 63* 67 72 62 63* 67 72 62 63* 67 72 (16.7) (17.2) (19.4) (22.2) (16.7) (17.2) (19.4) (22.2) (19.7) (17.2) (19.4) (22.2) TC 36.2 36.8 39.7 43.8 36.9 37.4 40.3 44.4 37.9 38.1 41.0 45.1 75 SHC 33.2 26.7 27.8 22.3 34.7 27.9 29.0 23.1 36.9 29.6 30.9 24.2 (23.9) kW 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.8 2.8 2.8 2.8 2.9 TC 34.6 35.1 37.9 41.8 35.3 35.6

Summary of the content on the page No. 14

14 50XP PERFORMANCEDATA(CONT) 50XP048 EvaporatorAir --- CFM/BF Temp_F(_C)Outdoor 1260/0.06 1400/0.06 1600/0.08 AirEntering EvaporatorAir --- Ewb_F(_C) Condenser 62 63* 67 72 62 63* 67 72 62 63* 67 72 (16.7) (17.2) (19.4) (22.2) (16.7) (17.2) (19.4) (22.2) (19.7) (17.2) (19.4) (22.2) TC 45.0 45.8 49.6 54.7 46.7 47.3 51.2 56.3 48.1 48.7 52.5 57.8 75 SHC 39.3 32.0 33.4 27.2 42.6 34.3 35.8 28.9 45.8 36.8 38.4 30.6 (23.9) kW 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.5 3.4 3.4 3.4 3.5 TC 42.8 43.6 47.2 52.1 44.3

Summary of the content on the page No. 15

15 PERFORMANCEDATA(CONT) *At75 °F(24 °C)enteringdry bulb---TennesseeValley Authority (TVA)ratingconditions; all othersat80 °F(27 °C) dry bulb. LEGEND BF—BypassFactor edb— EnteringDry---Bulb Ewb—EnteringWet---Bulb kW—Total UnitPower Input SHC—Sensible HeatCapacity (1000Btuh) TC —Total Capacity (1000Btuh) (net) rh—Relative Humidity COOLING NOTES: 1.Ratingsarenet; they accountfor theeffectsof theevaporator---fan motor power andheat. 2.Directinterpolation ispermissible.Donotextrapolate. 3.Thefollowi

Summary of the content on the page No. 16

PERFORMANCEDATA(CONT) Economizer1--in.FilterPressureDrop(IN.W.C.) UNIT50XP PRESSURE DROP 024--036 0.20 042--060 0.25 MultiplicationFactors HEATERkWRATING VOLTAGE DISTRIBUTIONV/3/60 MULTIPLICATIONFACTOR 200 0.69 208 0.75 240 230 0.92 240 1.00 FilterPressureDropTable(IN.W.C.) CFM FILTER SIZE in.(mm) 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 20X20X1 0.05 0.07 0.08 0.10 0.12 0.13 0.14 0.15 — — — — — — — — — — — (508X508X25) 20X24X1 — — — 0.09 0.10 0.11

Summary of the content on the page No. 17

TYPICALPIPINGANDWIRING ROOF-MOUNTING CURB ROOF RETURN-AIR FLEXIBLE DUCT SUPPLY-AIR FLEXIBLE DUCT CEILING CONCENTRIC DIFFUSER BOX (FIELD-SUPPLIED) C00023 INDOOR THERMOSTAT RETURN AIR FROM TOP COVER POWER SOURCE DISCONNECT PER NEC* *NEC - NATIONAL ELECTRICAL CODE C00063 17 50XP

Summary of the content on the page No. 18

APPLICATIONDATA Condensate trap — A 2--in. (51 mm) condensate trap must be Maximum cooling airflow — To minimize the possibility of condensateblow--offfrom theevaporator,airflowthrough theunits field supplied. should notexceed 450 cfm per ton. 1” (25 mm) MIN. Minimum cooling airflow — Minimum cooling airflow is 350 TRAP OUTLET cfm per ton for standard cooling modes. Airflow can be lower in certain modeswhen humidity removalisan issue. 2” (51 mm) MIN. Minimum cooling operating outdoor air tempera

Summary of the content on the page No. 19

ELECTRICALDATA ELECTRICHEAT POWER SUPPLY VOLTAGE COMPRESSOR OFM IFM NOMINAL RANGE MAX UNIT NOMINAL V---PH---HZ FLA MCA FUSEor MOCP KW MIN MAX RLA LRA FLA FLA CKTBKR -/- -/- 22.0/22.0 30/30 --- 3.8/5 18.1/20.8 27.9/31.4 30/35 --- 50XP-024 208/230-1-60 187 253 13.5 61.0 0.8 4.3 5.4/7.2 26/30 37.9/42.9 40/45 --- 7.5/10 36.1/41.7 50.5/57.5 60/60 --- -/- -/- 23.6/23.6 30/30 --- 3.8/5 18.1/20.8 27.9/31.4 30/35 --- 50XP-030 208/230-1-60 187 253 15.9 73.0 0.8 4.3 5.4/7.2 26/30 37.9/42.9 40/45 --- 7.5/10

Summary of the content on the page No. 20

TYPICALWIRINGSCHEMATIC 208/230--1--60 A08460 20 50XP


Alternative user manuals
# User manual Category Download
1 Carrier 024 User manual Air Conditioner 588
2 Carrier 09DK054-094 User manual Air Conditioner 100
3 Carrier 09DK054-084 User manual Air Conditioner 48
4 Carrier 17DA User manual Air Conditioner 26
5 Carrier 09DC User manual Air Conditioner 32
6 Carrier 040-420 User manual Air Conditioner 66
7 Carrier 17EX User manual Air Conditioner 14
8 Carrier 19 User manual Air Conditioner 17
9 Carrier 1995 User manual Air Conditioner 31
10 Carrier 09BB User manual Air Conditioner 11
11 Carrier 19DG User manual Air Conditioner 17
12 Carrier 19XRV User manual Air Conditioner 90
13 Carrier 30GA User manual Air Conditioner 32
14 Carrier 30GB User manual Air Conditioner 178
15 Carrier 30GX080-176 User manual Air Conditioner 22
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21