Bryant LEGACY 580J user manual

User manual for the device Bryant LEGACY 580J

Device: Bryant LEGACY 580J
Category: Air Conditioner
Manufacturer: Bryant
Size: 5.28 MB
Added : 10/27/2013
Number of pages: 94
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant LEGACY 580J. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant LEGACY 580J.

For your convenience

If looking through the Bryant LEGACY 580J user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant LEGACY 580J on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant LEGACY 580J to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant LEGACY 580J User manual - Online PDF
Advertisement
« Page 1 of 94 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant LEGACY 580J but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant LEGACY 580J. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

580J
GASHEAT/ELECTRICCOOLINGPACKAGEDROOFTOP
3TO15NOMINALTONS
ProductData
C08515
(Unitshown with optionallouvered hailguard.)
the environmentally sound refrigerant

Summary of the content on the page No. 2

TABLEOFCONTENTS PAGE PAGE FEATURES AND BENEFITS .................... 3 COOLING TABLES ........................... 33 MODEL NUMBER NOMENCLATURE ............ 4 STATIC PRESSURE ADDERS .................. 53 FACTORY OPTIONS AND/OR ACCESSORIES ..... 6 FAN PERFORMANCE ......................... 56 AHRI COOLING RATING TABLES............... 8 ELECTRICAL INFORMATION ................. 69 HEAT RATING TABLE ......................... 9 MCA / MOCP ................................ 73 SOUND PERFORMANCE TABLE ....

Summary of the content on the page No. 3

FEATURESANDBENEFITS S Single cooling stage modelsare available from 3 -- 10 ton. S Two cooling stage modelsare available from 7.5 -- 15 ton. S SEER up to 13.0. S EER’supto11.1. S IEER’supto11.8. S Upto28%lighterthansimilarindustryunits. Lighterrooftopsmake easierreplacement jobs. S Utilityconnectionsare the same because 3 -- 12.5tonunitsfit onexistingBryant rooftopcurbs. Thissavestime and moneyonreplacement jobs. S Standardized componentsand layout. Standardized componentsand controlsmake servic

Summary of the content on the page No. 4

MODELNUMBERNOMENCLATURE 123456789 1011121314151617 5 8 0 J E 0 6 A 0 7 2 A 1 A 0 A A ____________ ______ ________ ______ UnitType Packaging 580J =Cooling/GasHeatRTU A=Standard Legacy Seriesw/PuronRefrigerant B=LTL Voltage FactoryInstalledOptions E = 460---3---60 0A=None J =208/230---1---60 P =208/230---3---60 Intake/ExhaustOptions T = 575---3---60 A=None B=Tempeconow/barorelief CoolingTons E=Tempeconow/barorelief&CO 2 04=3Ton H=Enthalpy econow/barorelief 05=4Ton L =Enthalpy econow/barorelief & C

Summary of the content on the page No. 5

Table1–FACTORY--INSTALLEDOPTIONSANDFIELD--INSTALLEDACCESSORIES FACTORY FIELD CATEGORY ITEM INSTALLED INSTALLED OPTION ACCESSORY Thru---the---baseelectricalorgas---lineconnections X X Cabinet SupplyDuctCover X 1 Cu/Cuindoorand/oroutdoorcoils X 1 CoilOptions Pre---coatedoutdoorcoils X 1 Premium,E---coatedoutdoorcoils X Humidity Control PerfectHumidity System (3 --- 12.5ton) X Condenser Protection Condensercoilhailguard(louvereddesign) X X Thermostats,temperaturesensors,andsubbases X RTUOpen---prot

Summary of the content on the page No. 6

FACTORYOPTIONSAND/ORACCESSORIES Economizer(dry--bulborenthalpy) PowerExhaustwithBarometricRelief Economizers save money. They bring in fresh, outside air Superior internal building pressure control. This field for ventilation; and provide cool, outside air to cool your installed accessory may eliminate the need for costly, building. This is the preferred method of low ambient external pressure control fans. sensors, economizers can cooling. When coupled to CO 2 RTUOpen,Multi--ProtocolController

Summary of the content on the page No. 7

FACTORYOPTIONSAND/ORACCESSORIES(cont.) The Legacy Line 580J--04--14 rooftop coupled with the OptionalStainlessSteelHeatExchanger Perfect Humidity system iscapable ofoperating innormal The stainless steel heat exchanger option provides the design cooling mode, subcooling mode, and hot gasreheat tubular heat exchanger be made out of a minimum 20 mode. Normal design cooling mode is when the unit will gauge type 409 stainless steel for applications where the operate under its normal sequence of oper

Summary of the content on the page No. 8

Table2–AHRICOOLINGRATINGTABLE Nom. Cooling NetCooling Total Power Unit Capacity SEER EER IEER Stages Capacity(MBH) (KW) (tons) A04 1 3 34.6 3.1 13.0 11.00 N/A A05 1 4 45.0 4.0 13.0 11.00 N/A A06 1 5 59.0 5.5 13.0 10.75 N/A A07 1 6 70.0 6.4 N/A 11.00 11.2 A08 1 7.5 88.0 8.0 N/A 11.00 11.2 D08 2 7.5 83.0 7.5 N/A 11.00 11.7 A09 1 8.5 97.0 8.8 N/A 11.00 11.2 D09 2 8.5 99.0 9.0 N/A 11.00 11.7 A12 1 10 117.0 10.6 N/A 11.00 11.2 D12 2 10 114.0 10.3 N/A 11.10 11.8 D14 2 12.5 140.0 12.9 N/A 10.80 11.0 D1

Summary of the content on the page No. 9

Table3–HEATINGRATINGTABLE -- NATURALGAS&PROPANE AL/SSHEAT EXCHANGER THERMAL TEMPRISE AFUE Units GasHeat EFFICIENCY INPUT/OUTPUT INPUT/OUTPUT (DEGF) (%) (%) STAGE1(MBH) STAGE2(MBH) LOW --- 72/59 25 --- 55 82% 81% MED --- 115/93 55 --- 85 80% 80% 04 HIGH --- --- --- --- --- LOW --- 72/59 25 --- 55 82% 81% 05 MED --- 115/93 35 --- 65 81% 80% HIGH --- 150/120 50 --- 80 80% 80% LOW --- 72/59 20 --- 55 82% 81% MED --- 115/93 30 --- 65 81% 80% 06 HIGH --- 150/120 40 --- 80 80% 80% LOW --- 72/59 25 ---

Summary of the content on the page No. 10

1 Table4–HEATINGRATINGTABLE -- LOWNO x LOW NOxHEAT EXCHANGER THERMAL TEMPRISE AFUE UNIT GASHEAT EFFICIENCY INPUT/OUTPUT INPUT/OUTPUT (DEGF) (%) (%) STAGE1(MBH) STAGE2(MBH) LOW --- 60/50 20 --- 50 81% 80% MED --- 90/74 30 --- 60 81% 81% 04 HIGH --- --- --- --- --- LOW --- 60/50 20 --- 50 81% 80% 05 MED --- 90/74 30 --- 60 81% 81% HIGH --- 120/101 40 --- 70 81% 80% LOW --- 60/50 15 --- 50 81% 80% MED --- 90/74 25 --- 60 80% 81% 06 HIGH --- 120/101 35 --- 70 80% 81% LOW --- 60/50 20 --- 50 81% N/A

Summary of the content on the page No. 11

Table6–MINIMUM -- MAXIMUMAIRFLOWRATINGS -- NATURALGAS&PROPANE COOLING HEATING UNIT HEATLEVEL MINIMUM MAXIMUM MINIMUM MAXIMUM LOW 990 2190 580J**04 MED 900 1500 1000 1550 HIGH --- --- LOW 990 2190 MED 1330 2460 580J**05 1200 2000 HIGH 1390 2220 LOW 990 2730 580J**06 MED 1500 2500 1330 2880 HIGH 1390 2780 LOW 990 3640 MED 1330 3450 580J**07 1800 3000 HIGH 1390 3170 LOW 1900 4750 580J**08 MED 2250 3750 2100 3900 HIGH 2270 3780 LOW 1900 4750 MED 2100 4560 580J**09 2550 4250 HIGH 2270 4250 LOW 2100 5

Summary of the content on the page No. 12

Table7–PHYSICALDATA (COOLING) 3 -- 6TONS 580J*04A 580J*05A 580J*06A 580J*07A RefrigerationSystem #Circuits/#Comp./Type 1/1/Scroll 1/1/Scroll 1/1/Scroll 1/1/Scroll Puronrrefrig.(R---410A)(lbs---oz) 5---10 8---8 10---11 14---2 Operating charge (lbs---oz) --- Perfect Humidity Unit 8---11 14---13 16---0 22---5 Metering Device Acutrol Acutrol Acutrol Acutrol High---press.Trip /Reset(psig) 630/505 630/505 630/505 630/505 Low---press.Trip /Reset(psig) 54/117 54/117 54/117 54/117 CompressorCapacity Stag

Summary of the content on the page No. 13

Table8–PHYSICALDATA (HEATING) 3 -- 6TONS 580J**04 580J**05 580J**06 580J**07 GasConnection #ofGasValves 1 1 1 1 4 ---13 / 0.18 --- 4 ---13 / 0.18 --- 4 ---13 / 0.18 --- 4 ---13 / 0.18 --- Nat.gassupplylinepress(in.w.g.)/(PSIG) 0.47 0.47 0.47 0.47 11 ---13 / 0.40 --- 11 ---13 / 0.40 --- 11 ---13 / 0.40 --- 11 ---13 / 0.40 --- LP supply linepress(in.w.g.)/ (PSIG) 0.47 0.47 0.47 0.47 HeatAnticipatorsetting(Amps) 1ststage 0.14 0.14 0.14 0.14 2nd stage 0.14 0.14 0.14 0.14 NaturalGasHeat #ofstages/#of

Summary of the content on the page No. 14

Table9–PHYSICALDATA (COOLING) 7.5 -- 8.5TONS 580J*08A 580J*08D 580J*09A 580J*09D Refrigeration System #Circuits/#Comp./Type 1/1/Scroll 2/2/Scroll 1/1/Scroll 2/2/Scroll RTPFmodelsR---410achargeA/B(lbs --- oz) 13 --- 12/--- 8 --- 5 / 8 --- 2 15 --- 4/--- 10 --- 5 / 10 --- 12 Alternate(MCHX)R---410achargeA/B(lbs --- oz) --- 4 --- 6 / 4 --- 6 --- --- Alternate(PerfectHumidity)R---410achargeA/B(lbs --- oz) --- 13 --- 3 / 13 --- 3 --- 16 --- 13 / 16 --- 13 Metering device Accutrol Accutrol Accutrol Ac

Summary of the content on the page No. 15

Table10–PHYSICALDATA (HEATING) 7.5 -- 8.5TONS 580J**08 580J**09 GasConnection #ofGasValves 1 1 Nat.gassupplylinepress(in.w.g.)/(PSIG) 4 ---13 / 0.18 --- 0.47 4 ---13 / 0.18 --- 0.47 LP supply linepress(in.w.g.)/ (PSIG) 11 ---13/0.40 --- 0.47 11 ---13/0.40 --- 0.47 HeatAnticipatorsetting (Amps) 1ststage 0.14 0.14 2nd stage 0.14 0.14 NaturalGasHeat #ofstages/#ofburners(total) 1/3 1/3 Connection Size 1/2” NPT 1/2” NPT Rolloutswitch opens/ closes 195/115 195/115 Temperature Rise 20 --- 50 20 --- 50

Summary of the content on the page No. 16

Table11–PHYSICALDATA (COOLING) 10 -- 15TONS 580J*12A 580J*12D 580J*14D 580J*16D Refrigeration System #Circuits/ #Comp. / Type 1/1/Scroll 2/2/Scroll 2/2/Scroll 2/2/Scroll RTPFmodelsR---410a chargeA/B(lbs --- oz) 20 --- 0 10 --- 5 / 10 --- 3 11 --- 0 / 11 --- 6 15---14/16---12 Alternate(MCHX) R---410a chargeA/B(lbs --- oz) --- 6 --- 0 / 6 --- 0 7 --- 6 / 8 --- 0 --- Alternate(PerfectHumidity) R---410a chargeA/B(lbs --- oz) --- 16 --- 10 / 16 --- 0 17 --- 10 / 18 --- 3 --- Meteringdevice Accutrol A

Summary of the content on the page No. 17

Table12–PHYSICALDATA (HEATING) 10 -- 15TONS 580J**12 580J**14 580J**16 GasConnection #ofGasValves 1 1 1 Nat.gassupplylinepress(in.w.g.)/(PSIG) 4 ---13 / 0.18 --- 0.47 4 ---13 / 0.18 --- 5 --- 13 / 0.18 --- 0.47 0.47 LP supply linepress(in.w.g.)/ (PSIG) 11 ---13/0.40 --- 0.47 11 ---13 / 0.40 --- 11 ---13 / 0.40 --- 0.47 0.47 HeatAnticipatorsetting (Amps) 1ststage 0.14 0.14 0.14 2nd stage 0.14 0.14 0.14 NaturalGasHeat #ofstages/#ofburners(total) 2/4 2/4 2/6 Connection Size 3/4” NPT 3/4” NPT 3/4” N

Summary of the content on the page No. 18

CURBS&WEIGHTSDIMENSIONS-- 580J04--07 C101225 Fig.1 -- Dimensions580J04--07 18 580J

Summary of the content on the page No. 19

CURBS&WEIGHTSDIMENSIONS-- 580J04--07(cont.) C101226 Fig.2 -- Dimensions580J04--07 C D B A C08337 Fig.3 -- ServiceClearance LOC DIMENSION CONDITION 48---in (1219mm) Unitdisconnectismounted onpanel 18---in (457mm) Nodisconnect,convenienceoutletoption A 18---in (457mm) Recommended serviceclearance 12---in (305mm) Minimumclearance 42---in (1067mm) Surfacebehind servicerisgrounded (e.g.,metal,masonry wall) B 36---in (914mm) Surfacebehind serviceriselectrically non---conductive(e.g.,wood,fiberglass) S

Summary of the content on the page No. 20

CURBS&WEIGHTSDIMENSIONS-- 580J04--07(cont.) D ALT CONNECTOR ACCESSORY ROOFCURB BC GAS POWER CONTROL A UNIT SIZE DRAIN PKG. ACCY. POWER ACCESSORY HOLE 3 1’-2” / ” [19] 4 CRBTMPWR001A01 CRRFCURB001A01 11 3 NPT [356] 1’-9 / ” 1’-4” 1 / ” 3 1 1 580J* 16 4 /4” [19] /2” [12.7] /2” [12.7] 04-07 [551] [406] [44.5] 1 NPT NPT NPT 2’-0” /2” [12.7] CRRFCURB002A01 CRBTMPWR003A01 [610] NPT NOTES: 1. Roof curb accessory is shipped disassembled. 2. Insulated panels. 3. Dimensions in [ ] are in millimeter


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21