Bryant 127A user manual

User manual for the device Bryant 127A

Device: Bryant 127A
Category: Air Conditioner
Manufacturer: Bryant
Size: 0.54 MB
Added : 10/27/2013
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant 127A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant 127A.

For your convenience

If looking through the Bryant 127A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant 127A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant 127A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant 127A User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant 127A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant 127A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

127A
Legacyt Line Air Conditioner
with Puronr Refrigerant
1--1/2 To 5 Nominal Tons (Sizes 018 to 060)
Installation Instructions
5. When passing refrigerant tubes through the wall, seal open-
SAFETY CONSIDERATIONS
ing with RTV or other pliable silicon--based caulk. (See Fig.
Improper installation, adjustment, alteration, service, maintenance,
1.)
or use can cause explosion, fire, electrical shock, or other
6. Avoid direct tubing contact with water pipes, duct work,
conditions which may cause deat

Summary of the content on the page No. 2

Make Piping Connections INSTALLATION Check Equipment and Job Site ! WARNING UNPACK UNIT Move to final location. Remove carton taking care not to damage PERSONAL INJURY AND ENVIRONMENTAL HAZARD unit. Inspect Equipment Failure to follow this warning could result in personal injury or death. File claim with shipping company prior to installation if shipment is damaged or incomplete. Locate unit rating plate on unit corner Relieve pressure and recover all refrigerant before system panel. It contains

Summary of the content on the page No. 3

Outdoor Unit Connected to Factory Approved Indoor Unit Outdoor unit contains correct system refrigerant charge for operation with factory approved ARI rated indoor unit when connected by 15 ft. (4.57 m) of field--supplied or factory--accessory tubing, and factory supplied filter drier. Check refrigerant charge for maximum efficiency. Refrigerant Tubing Connection Outdoor A05178 Connect vapor and liquid tubes to fittings on vapor and liquid Fig. 3 -- Liquid Line Filter Drier service valves (see T

Summary of the content on the page No. 4

Table 2 – Accessory Usage REQUIREDFOR REQUIREDFORLONGLINE SEACOAST ACCESSORY APPLICATIONS* APPLICATIONS (Within2miles/3.22km) BallBearing FanMotor No No CompressorStartAssistCapacitorandRelay Yes No Crankcase Heater Yes No EvaporatorFreezeThermostat No No Hard Shut---Off TXV Yes Yes LiquidLineSolenoidValve No No ® MotorMaster orLow---ambientPressure Switch No No SupportFeet No Recommended WinterStartControl No No * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 35 ft. (10

Summary of the content on the page No. 5

Airflow Selection for Variable Speed Furnaces SYSTEM FUNCTIONS AND SEQUENCE The variable speed furnaces provide blower operation to match the OF OPERATION capacities of the compressor during high and low stage cooling The 127A models utilize a 2-stage cooling indoor thermostat. With operation. The furnace control board allows the installing a call for first stage cooling, the outdoor fan and low-stage technician to select the proper airflows for each stage of cooling. compressor are energized. I

Summary of the content on the page No. 6

Check Charge TROUBLESHOOTING The 127A units may be charged in high-- or low--stage compressor If the compressor fails to operate with a cooling call, the table operation. Factory charge amount and desired subcooling are below (Resistance table) can be used to verify if there is any shown on unit rating plate. Charging method is shown on damage to the compressor windings causing system malfunction. information plate inside unit. To properly check or adjust charge, conditions must be favorable for

Summary of the content on the page No. 7

MAJOR COMPONENTS CARE AND MAINTENANCE For continuing high performance and to minimize possible 2--Stage Compressor equipment failure, periodic maintenance must be performed on this The 2--stage compressor contains motor windings that provide equipment. 2--pole (3500 RPM) operation. Frequency of maintenance may vary depending upon geographic Compressor Internal Relief areas, such as coastal applications. See Owner’s Manual for The compressor is protected by an internal pressure relief (IPR) infor

Summary of the content on the page No. 8

TWO-STAGE Variable Speed Two-Stage THERMIDISTAT AIR CONDITIONER Air Conditioner Fan Coil Thermidistat O Y1 Y1 RVS/Heat Stage 2 O/W2/B W1 Heat Stage 1 W/W1 REMOVE J2 JUMPER FOR Compressor Low Y1 W2 HEAT STAGING Y2 Compressor High Y/Y2 Y/Y2 Fan G G 24VAC Hot Heating Rh R REMOVE J1 FOR 24VAC Hot Cooling Rc DEHUMIDIFY DH MODES Dry Contact 1 D1 C C Dry Contact 2 D2 24VAC Common C Humidify HUM Humidifier Solenoid Outdoor Air Temp OAT Valve Remote Room Sensor RRS Outdoor Sensor OAT/RRS Return SRTN

Summary of the content on the page No. 9

PURONR (R--410A) REFRIGERANT QUICK REFERENCE GUIDE S Puron refrigerant operates at 50--70 percent higher pressures than R--22. Be sure that servicing equipment and replacement components are designed to operate with Puron refrigerant S Puron refrigerant cylinders are rose colored. S Recovery cylinder service pressure rating must be 400 psig, DOT 4BA400 or DOT BW400. S Puron refrigerant systems should be charged with liquid refrigerant. Use a commercial type metering device in the manifold hose w

Summary of the content on the page No. 10

E2009 BryantHeating &Cooling SystemsD 7310 W. MorrisSt.D Indianapolis, IN 46231 Printed inU.S.A. EditionDate: 12/09 CatalogNo.II127A---01 Replaces:New Manufacturer reserves therighttodiscontinue,or changeatanytime,specifications or designs withoutnoticeandwithoutincurringobligations. 10 127A


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21