York ZJ R-410A user manual

User manual for the device York ZJ R-410A

Device: York ZJ R-410A
Category: Air Conditioner
Manufacturer: York
Size: 3.22 MB
Added : 5/22/2014
Number of pages: 104
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York ZJ R-410A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York ZJ R-410A.

For your convenience

If looking through the York ZJ R-410A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York ZJ R-410A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York ZJ R-410A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York ZJ R-410A User manual - Online PDF
Advertisement
« Page 1 of 104 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York ZJ R-410A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York ZJ R-410A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

251934-YTG-G-0708
 
Description
TECHNICAL GUIDE
®
YORK ZJ Series Sunline Magnum™ /ZR Series
MagnaDRY™/ZF Series Sunline™ units are convertible single
package high efficiency rooftops. All models have independent
refrigeration circuits for efficient part load operation.
Although the units are primarily designed for curb mounting on
a roof, they can also be slab-mounted at ground level or set on
steel beams above a finished roof.
All ZJ/ZR/ZF units are self-contained and assembled on rigid

Summary of the content on the page No. 2

251934-YTG-G-0708 Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

251934-YTG-G-0708 Component Location (ZJ shown) ® Simplicity Control Board Slide In/ Plug In Internal Economizer (Optional) 110 Volt Convenience Outlet (“Powered” or 2” Disposable Filters “Non-Powered” Optional) (4” Filters Optional) Disconnect Location (Optional Disconnect Switch) Bottom Power and Control Wiring Entry Power Ventor Motor Electric Heater Location (Optional Electric/Electric Units) Location of VFD (Optional) Location of VFD Bypass (Optional) Belt Drive Copper Tube/ Blower Motor T

Summary of the content on the page No. 4

251934-YTG-G-0708 Nomenclature 15-25 Ton Sunline Magnum™ Model Number Nomenclature Z J 180 N24 A 2 A AA 1 0 1 2 4 A Product Category Product Style Z = A/C, Single Pkg., R-410A A = Style A Product Identifier Configuration Options (not required for all units) These four digits will not be assigned until a quote is requested, or an order placed. J = 11.0+ EER A/C SS Drain Pan R = 90.1 w/Reheat CPC Controller, DFS, APS F = 10 thru 11 EER A/C Johnson Controller UNT 1126 (N2 protocol), DFS, APS Nomina

Summary of the content on the page No. 5

251934-YTG-G-0708 the intake damper assembly should be mounted over the Features and Benefits opening in the return air panel. With horizontal ductwork, it should be mounted on the return air duct. Standard Features • System Protection - Suction line freezestats are supplied • High Efficiency - High efficiency units reach as high as on all units to protect against loss of charge and coil frosting 12.4 EER. Gas/electric units have electronic spark ignition when the economizer operates at lo

Summary of the content on the page No. 6

251934-YTG-G-0708 can be reviewed at any time. Alarms and programmed streams are available for single enthalpy and differential values are retained through the loss of power. enthalpy configurations, respectively). • Reliable - From the beginning - All units undergo The rainhood is painted to match the basic unit and must computer automated testing before they leave the factory. be field-assembled before installing. Units are tested for refrigerant charge and pressure, unit • Power Exhaust

Summary of the content on the page No. 7

251934-YTG-G-0708 A ‘VFD-ready’ option provides the provisions for a customer-installed drive. The unit comes with a mounting bracket installed in the Blower Access compartment which may accommodate other vendor’s drives depending on Factory installed smoke detectors in the return air, may their size. In order to utilize the unit’s mounting bracket, be subjected to freezing temperatures during “off” times the maximum recommended drive dimensions are as due to out side air infiltration. t

Summary of the content on the page No. 8

251934-YTG-G-0708 savings by recovering the building from the Unoccupied • High Altitude Natural Gas - Burner orifices and pilot Setpoints to the Occupied Setpoints just in time for the orifices are provided for proper furnace operation at Occupied Time Period to begin. The Simplicity™ altitudes up to 6,000 feet. INTELLI-Comfort™ balances space temperature, • Propane - Burner orifices, pilot orifices and gas valve parts ventilation air temperature, CO and humidity for ultimate are provided

Summary of the content on the page No. 9

251934-YTG-G-0708 can also be slab-mounted at ground level or set on steel beams They shall have built-in field convertible duct connections for above a finished roof. Cooling only, cooling with gas heat and down discharge supply/return or horizontal discharge supply/ cooling with electric heat models are available with a wide return, and be available with factory installed options or field variety of factory-mounted options and field-installed installed accessories. The units shall be factor

Summary of the content on the page No. 10

251934-YTG-G-0708 equipped with VFD’s shall have factory-installed manual bypass should any of the following standard safety devices trip as an option. and shut off compressor. c. Loss-of-charge/Low-pressure switch. Outdoor (Condenser) Fan Assembly 1. High-pressure switch. The outdoor fans shall be of the direct-driven propeller type, 2. Freeze-protection thermostat, evaporator coil. If any of discharge air vertically, have aluminum blades riveted to the above safety devices trip, a LED (ligh

Summary of the content on the page No. 11

251934-YTG-G-0708 Unit Operating Characteristics position when the indoor fan motor is de-energized. Dampers shall fully close on power loss. Unit shall be capable of starting and running at 125° F outdoor temperature, exceeding maximum load criteria of ARI Standard Other Pre-engineered Accessories Available 340/360. The compressor, with standard controls, shall be • Roof Curb - 14" high, full perimeter curb with wood nailer capable of operation down to 25° F outdoor temperature. (shipped

Summary of the content on the page No. 12

251934-YTG-G-0708 • BAS Ready Economizer (2-10 V.D.C. Actuator Without a Indoor blower operation is initiated upon a call for first stage Controller) cooling, second stage cooling or dehumidification. • Hinged Filter Door Access And Tool Free Access Anytime there is a call for 2 stages of cooling, the unit will not Panels operate in the reheat mode, even if there is a call for • Hinged Tool Free Blower, Blower Motor, Filter And dehumidification at "HUM". Electrical Access Panels The unit w

Summary of the content on the page No. 13

251934-YTG-G-0708 Reheat Control Board R Y1 P4 Y2 K1 G W1 K2 W2 OCC K4 C K3 COM ` P6 P5 P3 HGRR HGR HUM DEHUMIDISTAT MODE HARNESS SELECTION CONNECTION JUMPER Reheat Controls - Part 1 Johnson Controls Unitary Products 13

Summary of the content on the page No. 14

251934-YTG-G-0708 UCB RHB UNIT CONTROL REHEAT CONTROL BOARD BOARD HUM HUMIDIFY TERMINAL RHR REHEAT RELAY RHTB REHEAT TERMINAL BLOCK Reheat Controls - Part 2 REHEAT SOLENOID 1 REHEAT REHEAT SOLENOID 3 SOLENOID 2 UCB UNIT CONTROL BOARD RHB REHEAT CONTROL BOARD 14 Johnson Controls Unitary Products

Summary of the content on the page No. 15

251934-YTG-G-0708 Physical Data ZJ180-300 Physical Data Models Component ZJ180 ZJ210 ZJ240 ZJ300 Nominal Tonnage 15 17.5 20 25 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (Btu) 183500 213700 242000 312000 ARI net capacity (Btu) 178500 206000 235000 295000 EER 12.4 12.1 11.6 10.4 SEER - - - - IPLV 13.9 13.2 12.9 10.6 Nominal CFM 6000 7000 8000 10000 System power (KW) 14.40 17.10 20.10 28.50 Refrigerant type R-410a R-410a R-410a R-410a Refrigerant charge (lb-oz) System 1 12-8 12-8 12-0 1

Summary of the content on the page No. 16

251934-YTG-G-0708 ZJ180-300 Physical Data (Continued) Models Component ZJ180 ZJ210 ZJ240 ZJ300 Nominal Tonnage 15 17.5 20 25 CONDENSER FAN DATA Quantity 4 4 4 4 Fan diameter (Inch) 24 24 30 30 Type Prop Prop Prop Prop Drive type Direct Direct Direct Direct No. speeds 1 1 1 1 Number of motors 2 2 2 2 Motor HP each 1/3 1/3 1/3 1/3 RPM 850 850 870 870 Nominal total CFM 4000 4000 5000 5000 BELT DRIVE EVAP FAN DATA Quantity 1 1 1 1 Fan Size (Inch) 15 X 15 18 X 15 18 X 15 18 X 15 Type Centrifugal Cen

Summary of the content on the page No. 17

251934-YTG-G-0708 ZR180-300 Physical Data Models Component ZR180 ZR240 ZR300 Nominal Tonnage 15 20 25 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (Btu) 189 243 303 ARI net capacity (Btu) 183 235 288 EER 11.6 12.1 10.5 SEER - - - IPLV 12.4 13.8 11.3 Nominal CFM 6000 8000 10000 System power (KW) 14.40 20.10 28.50 Refrigerant type R-410a R-410a R-410a Refrigerant charge (lb-oz) System 1 22 24 25 System 2 22 24 24-8 ARI HEATING PERFORMANCE Heating model 24 32 24 32 24 32 Heat input (K Btu)

Summary of the content on the page No. 18

251934-YTG-G-0708 ZR180-300 Physical Data (Continued) Models Component ZR180 ZR240 ZR300 Nominal Tonnage 15 20 25 CONDENSER FAN DATA Quantity 4 4 4 Fan diameter (Inch) 24 30 30 Type Prop Prop Prop Drive type Direct Direct Direct No. speeds 1 1 1 Number of motors 4 4 4 Motor HP each 1/3 3/4 3/4 RPM 850 870 870 Nominal total CFM 4000 5000 5000 BELT DRIVE EVAP FAN DATA Quantity 1 1 1 Fan Size (Inch) 15 X 15 18 X 15 18 X 15 Type Centrifugal Centrifugal Centrifugal Motor Sheave 1VP65 1VP65 1VP60 1VP

Summary of the content on the page No. 19

251934-YTG-G-0708 ZF180-300 Physical Data Models Component ZF180 ZF210 ZF240 ZF300 Nominal Tonnage 15 17.5 20 25 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (K Btu) 181 208 259 279 ARI net capacity (K Btu) 174 203 250 270 EER 11.0 11.0 10.0 10.0 SEER - - - - IPLV 12.9 12.77 11.5 11 Nominal CFM 6000 7000 8000 10000 System power (KW) 15.8 18.5 25.0 27.0 Refrigerant type R-410a R-410a R-410a R-410a Refrigerant charge (lb-oz) System 1 20-8 23-8 22 22 System 2 20-8 23-8 23 23-4 ARI HEATING

Summary of the content on the page No. 20

251934-YTG-G-0708 ZF180-300 Physical Data (Continued) Models Component ZF180 ZF210 ZF240 ZF300 Nominal Tonnage 15 17.5 20 25 CONDENSER FAN DATA Quantity 2 2 2 2 Fan diameter (Inch) 24 24 30 30 Type Prop Prop Prop Prop Drive type Direct Direct Direct Direct No. speeds 1 1 1 1 Number of motors 2 2 2 2 Motor HP each 1.25 1.25 1.25 1.25 RPM 1140 1140 1140 1140 Nominal total CFM 5765 7000 7000 7000 BELT DRIVE EVAP FAN DATA Quantity 1 1 1 1 Fan Size (Inch) 15 X 15 18 X 15 18 X 15 18 X 15 Type Centrif


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21