York YCJD18 THRU 60 user manual

User manual for the device York YCJD18 THRU 60

Device: York YCJD18 THRU 60
Category: Air Conditioner
Manufacturer: York
Size: 0.59 MB
Added : 5/22/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York YCJD18 THRU 60. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York YCJD18 THRU 60.

For your convenience

If looking through the York YCJD18 THRU 60 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York YCJD18 THRU 60 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York YCJD18 THRU 60 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York YCJD18 THRU 60 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York YCJD18 THRU 60 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York YCJD18 THRU 60. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

840569-YTG-A-0612
DESCRIPTION
The 13 SEER Series unit is the outdoor part of a versatile cli-
mate system. It is designed with a matching indoor coil compo-
nent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.
FEATURES
• Small Footprint - Extremely lightweight with a compact foot-
TECHNICAL GUIDE
print, it is a perfect fit for any application.
LX SERIES
• Quality Condenser Co

Summary of the content on the page No. 2

840569-YTG-A-0612 Physical and Electrical Data YCJD18 YCJD24 YCJD30 YCJD36 YCJD42 YCJD48 YCJD60 MODEL S41S1(H)(E) S41S1(H)(E) S41S1(H)(E) S41S1(H)(E) S41S2(H)(E) S41S1(H)(E) S41S1(E) Unit Supply Voltage 208-230V, 1  60Hz 1 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 10.0 12.4 14.7 17.9 21.5 21.1 34.3 2 15 20 25 30 35 35 60 Max. Overcurrent Device Amps 3 15 15 15 20 25 25 35 Min. Overcurrent Device Amps Compressor Type Rotary Recip Recip Recip Recip Recip Scroll Rated Load 7.6 9

Summary of the content on the page No. 3

840569-YTG-A-0612 System Charge for Various Matched Systems YCJD18 YCJD24 YCJD30 YCJD36 YCJD42 YCJD48 YCJD60 Outdoor Unit S41S1(H)(E) S41S1(H)(E) S41S1(H)(E) S41S1(H)(E) S41S2(H)(E) S41S1(H)(E) S41S1(E) 1,2 0.048/4F1 0.055/4F1 0.061/4F1 0.065/4G1 0.073/4G1 0.073/4H1 0.087/4J1 Required Orifice or TXV 3,4,5 Additional Charge, oz. Indoor Unit AHE18B 0–––– –– AHE24B –4––– –– AHE30B –40–– –– AHE36C –420– –– AHE42D –––8 10 –– AHE48D ––––9 0– AHE60D –––– 14 –4 AHP18 0–––– –– AHP30 –40–– –– AHP36 ––2

Summary of the content on the page No. 4

840569-YTG-A-0612 System Charge for Various Matched Systems (Continued) YCJD18 YCJD24 YCJD30 YCJD36 YCJD42 YCJD48 YCJD60 Outdoor Unit S41S1(H)(E) S41S1(H)(E) S41S1(H)(E) S41S1(H)(E) S41S2(H)(E) S41S1(H)(E) S41S1(E) 1,2 0.048/4F1 0.055/4F1 0.061/4F1 0.065/4G1 0.073/4G1 0.073/4H1 0.087/4J1 Required Orifice or TXV 3,4,5 Additional Charge, oz. Indoor Unit FC/MC/PC43 –4200–– FC/MC/PC48 –––8 10 4– FC/MC/PC60 ––––900 FC/MC62 –––– 14 –4 FC64 –––– 23 – 11 UC18 0–––––– UC36 –0––––– UC48 –––844– UC60 ––

Summary of the content on the page No. 5

840569-YTG-A-0612 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 13 SEER AC WITH AIR HANDLERS AHE18B 17.5 – 610 17.9 13.8 14.75 12.25 AHP18 17.5 – 650 17.5 12.9 13.00 11.00 AHR18B 17.5 – 665 17.8 13.8 13.00 11.00 AHX18 17.5 - 630 18.0 13.8 14.50 12.00 YCJD18S41S1(H)(E) AV*24 17.5 – 610 18.0 13.5 14.50 12.00 F4FP024 17.5 – 600 17.5 12.9 13.00 11.00 F6FP018 17.5 - 600 17.8 13.3 14.50 12.00 MV12B 17.5 FC/MC18B

Summary of the content on the page No. 6

840569-YTG-A-0612 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 13 SEER AC WITH AIR HANDLERS AHE36C 21.0 – 1190 35.6 25.4 14.25 12.00 AHE42D 24.5 – 1180 35.8 25.8 14.50 12.25 AHP36 21.0 – 1235 35.0 24.8 13.00 11.00 AHP42 21.0 – 1255 35.0 24.8 13.00 11.00 AHR36B 17.5 – 1245 34.6 24.6 13.00 11.00 AHR42C 21.0 – 1230 35.6 25.4 13.00 11.25 AHX36 21.0 – 1225 35.2 25.0 13.50 11.50 AHX42 24.5 – 1190 35

Summary of the content on the page No. 7

840569-YTG-A-0612 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 13 SEER AC WITH AIR HANDLERS AHE48D 24.5 – 1600 47.0 34.6 13.75 11.50 AHP48 24.5 – 1675 48.0 34.4 13.00 11.00 AHP60 24.5 – 1600 48.0 35.0 13.50 11.00 AHR48D 24.5 – 1610 48.0 34.6 13.00 11.00 AHX48 24.5 – 1660 48.0 35.4 13.50 11.50 AV*48 24.5 – 1625 48.0 35.0 13.50 12.00 AV*60 24.5 – 1560 48.0 35.0 13.50 12.00 F4FV060 24.5 – 1600 48

Summary of the content on the page No. 8

840569-YTG-A-0612 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings) COIL COOLING CFM RANGE NET MBH UNIT MODEL RATED 1 (MIN.-MAX.) MODEL WIDTH SEER EER CFM TOTAL SENS. 13 SEER AC COIL ONLY RATINGS FC/MC/PC18 14.5,17.5 450-750 600 17.5 12.9 13.00 11.00 YCJD18S41S1(H)(E) UC18 14.5,17.5 450-750 600 17.5 12.9 13.00 11.00 FC/MC/PC32 14.5 600-1000 800 24.0 16.7 13.00 11.00 FC/MC/PC35 17.5,21.0 600-1000 800 24.0 16.7 13.00 11.00 FC/MC/PC36 14.5,17.5,21.0 600-1000 8

Summary of the content on the page No. 9

840569-YTG-A-0612 COOLING CAPACITY - With High Efficiency Motor Furnaces FURNACE COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL WIDTH MODEL SEER EER CFM TOTAL SENS. 2 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*A12 14.5 FC/MC/PC18A 620 17.5 12.7 14.50 12.50 T*(8,L)V*A12 14.5 UC18A 620 17.5 12.7 14.50 12.00 T*(8,L)V*B12 17.5 FC/MC/PC18B 580 17.5 12.6 14.50 12.00 T*(8,L)V*B12 17.5 UC18B 580 17.5 12.5 14.50 12.00 T*(8,L)X*A12 14.5 FC/MC/PC18A 540 17.7 12.9 14.50 12.50 T*(8,L)X*A12 14.5

Summary of the content on the page No. 10

840569-YTG-A-0612 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL WIDTH MODEL SEER EER CFM TOTAL SENS. 2 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES Y*(8,L)C*A12 14.5 UC36A 805 23.6 16.6 13.80 11.50 Y*(8,L)C*B12 17.5 FC/MC/PC35B 760 24.0 16.8 14.00 12.00 Y*(8,L)C*B12 17.5 FC/MC/PC36B 765 24.0 17.0 14.00 12.00 Y*(8,L)C*B12 17.5 FC/MC/PC43B 760 24.0 16.9 14.00 12.00 YCJD24S41S1(H)(E) Y*(8,L)C*B12 17.5 UC36B 765 23.6 16.7

Summary of the content on the page No. 11

840569-YTG-A-0612 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL WIDTH MODEL SEER EER CFM TOTAL SENS. 2 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*A12 14.5 FC/MC/PC37A 980 33.8 23.0 13.50 11.00 T*(8,L)V*B12 17.5 FC/MC/PC43B 1210 35.2 25.2 13.50 11.00 T*(8,L)V*C16 21.0 FC/MC/PC43C 1205 35.6 25.4 14.00 11.50 T*(8,L)V*C16 21.0 FC/MC/PC48C 1210 36.0 26.0 14.00 12.00 T*(8,L)V*C16 21.0 UC48C 1210 34.6 24.8 13.50 11

Summary of the content on the page No. 12

840569-YTG-A-0612 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL WIDTH MODEL SEER EER CFM TOTAL SENS. 2 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*B12 17.5 FC/MC/PC43B 1270 41.0 28.8 13.25 11.25 T*(8,L)V*C16 21.0 FC/MC/PC43C 1390 42.0 30.2 13.50 11.50 T*(8,L)V*C16 21.0 FC/MC/PC48C 1330 42.0 29.8 13.50 11.50 T*(8,L)V*C16 21.0 FC/MC/PC48D 1330 42.0 29.8 13.50 11.50 T*(8,L)V*C16 21.0 FC/MC/PC60D 1420 42.0 30.0 1

Summary of the content on the page No. 13

840569-YTG-A-0612 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL WIDTH MODEL SEER EER CFM TOTAL SENS. 2 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES T*9(C,V)*C20 21.0 FC64D 1445 42.0 30.8 13.75 11.75 T*9(C,V)*C20 21.0 UC48C 1430 42.0 30.2 13.25 11.25 T*9(C,V)*C20 21.0 UC60C 1445 41.5 29.8 13.00 11.25 T*9(C,V)*D20 24.5 FC/MC/PC48D 1450 42.0 30.2 13.50 11.50 T*9(C,V)*D20 24.5 FC/MC/PC60D 1445 42.0 30.0 13.50 11.50 T*9(C,V

Summary of the content on the page No. 14

840569-YTG-A-0612 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL WIDTH MODEL SEER EER CFM TOTAL SENS. 2 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES Y*(8,L)C*C20 21.0 UC60C 1410 42.0 30.0 13.50 11.50 Y*9C*C16 21.0 FC/MC/PC43C 1360 42.0 30.0 13.25 11.25 Y*9C*C16 21.0 FC/MC/PC48C 1395 42.0 30.4 13.50 11.50 Y*9C*C16 21.0 FC/MC/PC48D 1395 42.0 30.4 13.50 11.50 Y*9C*C16 21.0 FC/MC/PC60D 1445 41.5 29.8 13.00 11.00 Y*9C*C16 21

Summary of the content on the page No. 15

840569-YTG-A-0612 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL WIDTH MODEL SEER EER CFM TOTAL SENS. 2 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES Y*9C*C20 21.0 FC/MC/PC48C 1655 48.0 34.8 13.20 11.00 Y*9C*C20 21.0 FC/PC60C 1655 48.0 35.2 13.10 11.00 YCJD48S41S1(H)(E) Y*9C*D20 24.5 FC/MC/PC48D 1645 48.0 35.2 13.20 11.00 Y*9C*D20 24.5 FC/MC/PC60D 1615 48.0 35.0 13.20 11.00 T*(8,L)V*C20 21.0 FC/MC62D 1615 56.5 37.4 13.50

Summary of the content on the page No. 16

840569-YTG-A-0612 Thermostats - Compatible thermostat controls are available ACCESSORIES through accessory sourcing. For optimum performance and Refer to Price Manual for specific model numbers. installation, refer to the UPGNET “Low Voltage Wiring Diagram” Off Cycle Timer Delay - Provides a 5-minute off cycle to pre- document to select and apply controls. vent rapid recycling of the compressor. Start Assist Kit (S1-2SA067*) - Provides increased starting SOUND POWER RATINGS torque for areas with

Summary of the content on the page No. 17

840569-YTG-A-0612 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YCJD18S41S1(H)(E) INDOOR COIL MODEL NO. FC/MC/PC18 IDCFM 450 600 750 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 16.3 18.4 18.3 20.1 20.7 17.5 19.0 18.7 20.2 20.9 18.7 19.6 19.1 20.3 21.1 65 S.C. 16.3 14.5 12.7 12.6 9.7 17.5 17.1 14.2 13.6 10.3 18.7 17.2 15.7 14.6 10.9 KW 1.16 1.16 1.16 1.15 1.14 1.21 1.21 1.21 1.20 1.20

Summary of the content on the page No. 18

840569-YTG-A-0612 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YCJD24S41S1(H)(E) INDOOR COIL MODEL NO. FC/MC/PC36 IDCFM 600 800 1000 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 20.5 25.5 25.4 27.0 28.2 22.6 26.7 26.5 28.3 29.5 24.7 28.0 27.7 29.6 30.8 65 S.C. 20.5 19.1 16.6 16.3 13.3 22.6 22.0 18.8 18.0 14.2 24.7 24.9 21.0 19.7 15.1 KW 1.66 1.67 1.67 1.67 1.67 1.73 1.74 1.74 1.74 1.

Summary of the content on the page No. 19

840569-YTG-A-0612 Furnaces Coils T.C. S.C. KW Furnaces Coils T.C. S.C. KW T*9X*A10 FC/MC/PC32A 1.00 1.01 0.94 T*(8,L)V*A12 FC/MC/PC32A 1.00 1.02 0.96 T*9X*A10 FC/MC/PC36A 1.01 1.01 0.94 T*(8,L)V*A12 FC/MC/PC36A 1.00 1.01 0.92 T*9X*A10 FC/MC/PC37A 1.02 1.02 0.95 T*(8,L)V*A12 FC/MC/PC37A 1.00 1.02 0.92 T*9X*B12 FC/MC/PC36B 1.00 1.01 0.92 T*(8,L)V*A12 UC36A 0.98 0.99 0.94 T*9X*C16 FC/MC/PC35C 0.99 0.98 0.91 T*(8,L)V*B12 FC/MC/PC35B 1.00 1.01 0.92 T*9X*C16 FC/MC/PC36C 1.00 1.01 0.92 T*(8,L)V*B12 FC/

Summary of the content on the page No. 20

840569-YTG-A-0612 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YCJD30S41S1(H)(E) INDOOR COIL MODEL NO. FC/MC/PC32 IDCFM 800 1000 1200 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 30.2 33.4 32.8 35.2 36.5 31.7 33.9 33.4 35.5 36.7 33.2 34.3 34.1 35.9 36.9 65 S.C. 28.9 26.3 22.1 21.6 16.3 30.3 29.5 24.0 23.0 17.4 31.8 32.6 25.9 24.4 18.5 KW 2.18 2.20 2.20 2.21 2.23 2.27 2.28 2.29 2.42 2


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1